Schneider Electric 9050JCK70V24 Timer Relay 240Vac 10Amp +Options

(No reviews yet) Write a Review
SKU:
9050JCK70V24
UPC:
785901132707
Condition:
New
Hold-In Power Consumption In Va:
3.2-3.2 VA
Ambient Air Temperature For Operation:
-18-122 °F
Rohs Exemption Information:
Yes
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Product Compatibility:
8501NR61 || 8501NR62
Circularity Profile:
ENVEOLI1406037EN
Time Delay Range:
0.1...99.9 min || 0.05...9.99 s || 1...999 s || 0.1...99.9 h || 0.1...99.9 s || 1...999 h
Product Certifications:
UL Listed || UL Recognized || CE
Warranty:
18 months
Environmental Disclosure:
ENVPEP1406037EN
Range Of Product:
9050JCK
Maximum Switching Voltage:
240 V AC
Pin Number:
11
Contacts Type And Composition:
2 NO + 2 NC
Sustainable Offer Status:
Green Premium product
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Shape Of Pin:
tubular
Mercury Free:
Yes
Product Or Component Type:
timer
Contacts Material:
silver nickel
Toxic Heavy Metal Free:
Yes
Depth:
91 mm
Line Rated Current:
0.416666666666667
China Rohs Regulation:
X
Mounting Support:
socket
Switch Function:
DPDT
[Uc] Control Circuit Voltage:
240 V AC
Height:
60 mm
Reach Free Of Svhc:
Yes
Width:
44 mm
Time Delay Type:
off-delay || trigger on-delay || one shot falling edge || one shot || on-delay and off-delay || watchdog || on-delay || repeat cycle || interval
  • Schneider Electric 9050JCK70V24 Timer Relay 240Vac 10Amp +Options
  • Schneider Electric 9050JCK70V24 Timer Relay 240Vac 10Amp +Options
  • Schneider Electric 9050JCK70V24 Timer Relay 240Vac 10Amp +Options
$173.00

Description

9050JCK plug in timers are designed to provide low cost timing in a plug in housing. This timer can be programed to have an on delay, off delay, interval, one shot, repeat cycle off, repeat cycle on, on/off delay, one shot falling edge, watchdog or trigger on delay timing mode. The timing range of 0.5 seconds to 999 hours is easily adjustable with thumb wheels on the top of the timer. This plug in timer plugs into an 8501NR61 or 8501NR62 relay socket. These relay sockets can be mounted on 35 mm DIN 3 mounting track or directly to a panel. All wiring is made to the relay socket. The DPDT contacts are rated 10 amperes resistive at 120 VAC, 240 VAC and 30 VDC, 3 amperes inductive at 120 VAC, 240 VAC and 30 VDC, 1/3 HP on the NC contacts at 120 VAC and 240 VAC, 1/2 HP on the NO contacts at 120 VAC and 240 VAC. This plug in timer is powered up with 240 VAC 50/60 Hz. 9050JCK plug in timers are UL listed when the proper 8501NR relay socket is used, UL component recognized and CSA certified.
View AllClose