Schneider Electric 9AS3D5 Electromechnical Power Relays, 5Vdc Pack of 10
SKU:
9AS3D5
UPC:
3606489915315
MPN:
Condition:
New
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Reset Time:
10 ms
Contacts Material:
silver alloy contacts
Product Certifications:
UL
Height:
50 mm
Dielectric Strength:
2500 V AC between coil and contact || 1500 V between contacts with micro disconnection
Maximum Switching Voltage:
277 V AC || 28 V DC
Silicon Free:
Yes
Ambient Air Temperature For Storage:
-40-85 °C
China Rohs Regulation:
X
Protection Category:
RT III
Product Or Component Type:
power relay
Ambient Air Temperature For Operation:
-40-40 °C
Input Current:
30 A
Eu Rohs Directive:
Compliant
Net Weight:
0.032 kg
Standards:
UL 60947-4-1
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Operating Position:
any position
Contacts Type And Composition:
NO
Minimum Switching Capacity:
5 W at 1 A, 5 V DC || 12 VA at 1 A, 12 V AC
[Uimp] Rated Impulse Withstand Voltage:
4 kV 1.2/50 µs
Circularity Profile:
ENVEOLI2006003EN
Depth:
27.8 mm
Mounting Support:
panel flange
Lead Free:
Yes
Network Frequency:
50-60 Hz
Connections - Terminals:
Faston terminals contact terminal AWG 12...AWG 10, connection size: 6.35 x 0.8 mm || Faston terminals coil terminal AWG 22...AWG 14, connection size: 4.8 x 0.5 mm
Average Coil Consumption:
0.9 W
Vibration Resistance:
+/- 0.75 mm 10-55 Hz operating || +/- 0.75 mm 10-55 Hz not operating
Pvc Free:
Yes
Switch Function:
SPST
Phenolic Free Solution:
Yes
Mercury Free:
Yes
Control Circuit Voltage Limits:
0.8...1.1 Uc
Rohs Exemption Information:
Yes
Range Of Product:
Harmony
Rated Power In Va:
470 VA at 240 V on pilot duty
Sustainable Offer Status:
Green Premium product
Pollution Degree:
3
Rated Power In Hp:
1 hp at 125 V AC || 2 hp at 250 V AC
Drop-Out Voltage Threshold:
>= 0.1 Uc
Reach Free Of Svhc:
Yes
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Operating Time:
20 ms
Electrical Durability:
100000 cycles, 30 A at 240 V, AC-1 || 50000 cycles for resistive load, 30 A at 28 V, DC || 100000 cycles for resistive load, 24 A at 240 V, AC || 30000 cycles for full load, 22 A at 120 V, AC-8a || 1000 cycles for motor load || 6000 cycles for ballas
[Ie] Rated Operational Current:
30 A at 240 V AC-1 || 30 A at 28 V DC (on resistive load) || 24 A at 240 V AC (on resistive load) || 98 A at 120 V AC-8a (locked rotor) || 22 A at 120 V AC-8a (full load) || 10 A at 277 V AC-5a (ballast)