Schneider Electric ATS01N206QN Soft-Start Stop 6A 380 415V

(No reviews yet) Write a Review
SKU:
ATS01N206QN
UPC:
3389110667202
Condition:
New
Utilisation Category:
AC-53B EN/IEC 60947-4-2
Standards:
EN/IEC 60947-4-2
Pollution Degree:
2 EN/IEC 60947-4-2
Rohs Exemption Information:
Yes
Supply Frequency:
50...60 Hz - 5...5 %
Starting Torque:
30...80 % of starting torque of motor connected directly on the line supply
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || > 3280.84 ft (1000 m) with current derating of 2.2 % per additional 100 m
[Us] Rated Supply Voltage:
380...415 V - 10...10 %
Height:
124 mm
Mercury Free:
Yes
Motor Power Kw:
3 kW, 3 phase 380...415 V || 1.5 kW, 3 phase 380...415 V || 2.2 kW, 3 phase 380...415 V
Warranty:
18 months
[Uc] Control Circuit Voltage:
built into the starter
Electrical Connection:
4 mm screw clamp terminal - rigid 1 1...10 mm² AWG 8 power circuit || screw connector - rigid without cable end 1 0.5...2.5 mm² AWG 14 control circuit || 4 mm screw clamp terminal - rigid 2 1...6 mm² AWG 10 power circuit || screw connector - rigid 2
Reach Free Of Svhc:
Yes
Product Destination:
asynchronous motors
Network Frequency:
47.5...63 Hz
Discrete Input Logic:
positive LI1, LI2, BOOST < 5 V <= 0.2 mA > 13 V, >= 0.5 mA
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Display Type:
1 LED Green)starter powered up || 1 LED Yellow)nominal voltage reached
Minimum Switching Current:
10 mA 6 V DC relay outputs
Type Of Start:
start with voltage ramp
Power Range:
1.1-2 kW 380-440 V 3 phase || 2.2-3 kW 380-440 V 3 phase
Range Of Product:
Altistart 01
Discrete Output Current:
2 A DC-13 || 3 A AC-15
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Discrete Input Voltage:
24...40 V
Tightening Torque:
1.9-2.5 N.m || 0.5-0.5 N.m
Product Certifications:
UL || B44.1-96/ASME A17.5 for starter wired to the motor delta terminal || CSA || GOST || C-tick || CCC
Ip Degree Of Protection:
IP20
Maximum Switching Current:
relay outputs 2 A 250 V AC cos phi = 0.5 20 ms inductive || relay outputs 2 A 30 V DC cos phi = 0.5 20 ms inductive
Product Specific Application:
simple machine
Depth:
131 mm
Output Voltage:
<= power supply voltage
Toxic Heavy Metal Free:
Yes
Starting Time:
1 s / 100 || 5 s / 20 || 10 s / 10 || adjustable from 1 to 10 s
Relative Humidity:
5-95 % without condensation or dripping water EN/IEC 60068-2-3
Marking:
CE
Product Or Component Type:
soft starter
Compatibility Code:
ATS01N2
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Shock Resistance:
15 gn 11 ms EN/IEC 60068-2-27
Discrete Output Type:
open collector logic LO1 end of starting signal || relay outputs R1A, R1C NO
Electromagnetic Compatibility:
conducted and radiated emissions level B CISPR 11 || conducted and radiated emissions level B IEC 60947-4-2 || damped oscillating waves level 3 IEC 61000-4-12 || electrostatic discharge level 3 IEC 61000-4-2 || EMC immunity level 3 EN 50082-1 || EMC
Vibration Resistance:
1 gn 13-150 Hz)EN/IEC 60068-2-6 || 1.5 mm peak to peak 3-13 Hz)EN/IEC 60068-2-6
Supply Voltage Limits:
342-456 V
Assembly Style:
with heat sink
Ambient Air Temperature For Operation:
-10-40 °C without derating) || 40-50 °C with current derating of 2 % per °C)
Icl Starter Rating:
0.25
Motor Starter Type:
soft starter
Operating Position:
vertical +/- 10 degree
Phase:
3 phase
Current Consumption:
30 A at nominal load
Deceleration Time Symb:
adjustable from 1 to 10 s
China Rohs Regulation:
X
Power Dissipation In W:
4 W at full load and at end of starting || 64 W in transient state
Function Available:
integrated bypass
Width:
45 mm
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Discrete Output Voltage:
24 V 6...30 V) open collector logic
Net Weight:
0.42 kg
Device Short Name:
ATS01
Ambient Air Temperature For Storage:
-25-70 °C EN/IEC 60947-4-2
Discrete Input Type:
logic LI1, LI2, BOOST) stop, run and boost on start-up functions <= 8 mA 27 kOhm
  • Schneider Electric ATS01N206QN Soft-Start Stop 6A 380 415V
  • Schneider Electric ATS01N206QN Soft-Start Stop 6A 380 415V
$159.60

Description

This Altistart 01 soft starter is DIN rail mounted and can feed 3-phase asynchronous motors with a rating up to 6A. This Altistart 01 can be used for a motor rated power up to 1.1kW or 1.5hp for 3-phase (200V to 240V AC). This DIN rail mounted soft starter is designed to enable smooth start for simple machines such as conveyors, conveyor belts, pumps, fans, compressors, automatic doors and gates, small cranes and belt-driven machinery. It is 45mm wide, this makes it one of the smallest soft starters on the market; it can be installed nearly everywhere. It features an Integrated bypass, this reduces noise and decreases heat dissipation. Simple setup with only 2 settings: possible to configure by non-specialists. It provides smooth starting for your machinery, avoiding mechanical stresses and extending their service life.