Schneider Electric ATS01N222LU Soft-Start Stop 22A 220 240V

(No reviews yet) Write a Review
SKU:
ATS01N222LU
UPC:
3389110667288
Condition:
New
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Network Frequency:
47.5...63 Hz
Range Of Product:
Altistart 01
Mercury Free:
Yes
Net Weight:
0.56 kg
Depth:
131 mm
Starting Time:
1 s / 100 || 5 s / 20 || 10 s / 10 || adjustable from 1 to 10 s
Discrete Input Type:
logic LI1, LI2, BOOST) stop, run and boost on start-up functions <= 8 mA 27 kOhm
Discrete Input Logic:
positive LI1, LI2, BOOST < 5 V <= 0.2 mA > 13 V, >= 0.5 mA
Electrical Connection:
4 mm screw clamp terminal - rigid 1 1...10 mm² AWG 8 power circuit || screw connector - rigid without cable end 1 0.5...2.5 mm² AWG 14 control circuit || 4 mm screw clamp terminal - rigid 2 1...6 mm² AWG 10 power circuit || screw connector - rigid 2
Warranty:
18 months
Product Certifications:
GOST || CSA || C-tick || UL || B44.1-96/ASME A17.5 for starter wired to the motor delta terminal || CCC
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Maximum Horse Power Rating:
5 hp, 3 phase 200...240 V || 7.5 hp, 3 phase 200...240 V
Product Or Component Type:
soft starter
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Icl Starter Rating:
22 A
Compatibility Code:
ATS01N2
China Rohs Regulation:
X
Type Of Start:
start with voltage ramp
Vibration Resistance:
1 gn 13-150 Hz)EN/IEC 60068-2-6 || 1.5 mm peak to peak 3-13 Hz)EN/IEC 60068-2-6
Relative Humidity:
5-95 % without condensation or dripping water EN/IEC 60068-2-3
Ambient Air Temperature For Operation:
-10-40 °C without derating) || 40-50 °C with current derating of 2 % per °C)
Motor Starter Type:
soft starter
Marking:
CE
Reach Free Of Svhc:
Yes
Current Consumption:
110 A at nominal load
Supply Voltage Limits:
180-264 V
Rohs Exemption Information:
Yes
Discrete Output Current:
2 A DC-13 || 3 A AC-15
Phase:
3 phase
Height:
154 mm
[Uc] Control Circuit Voltage:
built into the starter
Starting Torque:
30...80 % of starting torque of motor connected directly on the line supply
Product Specific Application:
simple machine
Supply Frequency:
50...60 Hz - 5...5 %
Discrete Input Voltage:
24...40 V
Width:
45 mm
Ip Degree Of Protection:
IP20
Discrete Output Type:
open collector logic LO1 end of starting signal || relay outputs R1A, R1C NO
Function Available:
integrated bypass
Power Dissipation In W:
124.5 W in transient state || 4.5 W at full load and at end of starting
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Ambient Air Temperature For Storage:
-25-70 °C EN/IEC 60947-4-2
[Us] Rated Supply Voltage:
200...240 V - 10...10 %
Motor Power Kw:
4 kW, 3 phase 200...240 V || 5.5 kW, 3 phase 200...240 V
Maximum Switching Current:
relay outputs 2 A 250 V AC cos phi = 0.5 20 ms inductive || relay outputs 2 A 30 V DC cos phi = 0.5 20 ms inductive
Minimum Switching Current:
10 mA 6 V DC relay outputs
Shock Resistance:
15 gn 11 ms EN/IEC 60068-2-27
Electromagnetic Compatibility:
conducted and radiated emissions level B CISPR 11 || conducted and radiated emissions level B IEC 60947-4-2 || damped oscillating waves level 3 IEC 61000-4-12 || electrostatic discharge level 3 IEC 61000-4-2 || EMC immunity level 3 EN 50082-1 || EMC
Assembly Style:
with heat sink
Operating Position:
vertical +/- 10 degree
Tightening Torque:
0.5-0.5 N.m || 1.9-2.5 N.m
Output Voltage:
<= power supply voltage
Utilisation Category:
AC-53B EN/IEC 60947-4-2
Pollution Degree:
2 EN/IEC 60947-4-2
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || > 3280.84 ft (1000 m) with current derating of 2.2 % per additional 100 m
Standards:
EN/IEC 60947-4-2
Device Short Name:
ATS01
Display Type:
1 LED Green)starter powered up || 1 LED Yellow)nominal voltage reached
Deceleration Time Symb:
adjustable from 1 to 10 s
Power Range:
4-6 kW 200-240 V 3 phase
Product Destination:
asynchronous motors
Discrete Output Voltage:
24 V 6...30 V) open collector logic
Toxic Heavy Metal Free:
Yes
$262.80

Description

This Altistart 01 soft starter is DIN rail mounted and can feed 3-phase asynchronous motors with a rating up to 22A. This Altistart 01 can be used for a motor rated power up to 5.5kW or 7.5hp for 3-phase (200V to 240V AC). This DIN rail mounted soft starter is designed to enable smooth start for simple machines such as conveyors, conveyor belts, pumps, fans, compressors, automatic doors and gates, small cranes and belt-driven machinery. It is 45mm wide, this makes it one of the smallest soft starters on the market; it can be installed nearly everywhere. It features an Integrated bypass, this reduces noise and decreases heat dissipation. Simple setup with only 2 settings: possible to configure by non-specialists. It provides smooth starting for your machinery, avoiding mechanical stresses and extending their service life.
View AllClose