Power Range:
7-11 kW 200-240 V 3 phase
Tightening Torque:
1.9-2.5 N.m || 0.5-0.5 N.m
Discrete Output Type:
open collector logic LO1 end of starting signal || relay outputs R1A, R1C NO
Maximum Switching Current:
relay outputs 2 A 250 V AC cos phi = 0.5 20 ms inductive || relay outputs 2 A 30 V DC cos phi = 0.5 20 ms inductive
Supply Voltage Limits:
180-264 V
Deceleration Time Symb:
adjustable from 1 to 10 s
Rohs Exemption Information:
Yes
Electrical Connection:
4 mm screw clamp terminal - rigid 1 1...10 mm² AWG 8 power circuit || screw connector - rigid without cable end 1 0.5...2.5 mm² AWG 14 control circuit || 4 mm screw clamp terminal - rigid 2 1...6 mm² AWG 10 power circuit || screw connector - rigid 2
Reach Free Of Svhc:
Yes
Utilisation Category:
AC-53B EN/IEC 60947-4-2
Supply Frequency:
50...60 Hz - 5...5 %
Discrete Output Current:
2 A DC-13 || 3 A AC-15
Type Of Start:
start with voltage ramp
Starting Torque:
30...80 % of starting torque of motor connected directly on the line supply
Height:
154 mm
Toxic Heavy Metal Free:
Yes
Device Short Name:
ATS01
Current Consumption:
160 A at nominal load
Range Of Product:
Altistart 01
Product Specific Application:
simple machine
Compatibility Code:
ATS01N2
Electromagnetic Compatibility:
conducted and radiated emissions level B CISPR 11 || conducted and radiated emissions level B IEC 60947-4-2 || damped oscillating waves level 3 IEC 61000-4-12 || electrostatic discharge level 3 IEC 61000-4-2 || EMC immunity level 3 EN 50082-1 || EMC
Power Dissipation In W:
4.5 W at full load and at end of starting || 324.5 W in transient state
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Maximum Horse Power Rating:
10 hp, 3 phase 200...240 V
Ambient Air Temperature For Operation:
-10-40 °C without derating) || 40-50 °C with current derating of 2 % per °C)
Operating Position:
vertical +/- 10 degree
Network Frequency:
47.5...63 Hz
Product Destination:
asynchronous motors
Vibration Resistance:
1 gn 13-150 Hz)EN/IEC 60068-2-6 || 1.5 mm peak to peak 3-13 Hz)EN/IEC 60068-2-6
Output Voltage:
<= power supply voltage
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
[Us] Rated Supply Voltage:
200...240 V - 10...10 %
Mercury Free:
Yes
Motor Power Kw:
7.5 kW, 3 phase 200...240 V
Product Or Component Type:
soft starter
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || > 3280.84 ft (1000 m) with current derating of 2.2 % per additional 100 m
Warranty:
18 months
Net Weight:
0.56 kg
Display Type:
1 LED Green)starter powered up || 1 LED Yellow)nominal voltage reached
Marking:
CE
Function Available:
integrated bypass
Relative Humidity:
5-95 % without condensation or dripping water EN/IEC 60068-2-3
[Uc] Control Circuit Voltage:
built into the starter
Discrete Input Logic:
positive LI1, LI2, BOOST < 5 V <= 0.2 mA > 13 V, >= 0.5 mA
Discrete Input Voltage:
24...40 V
Discrete Input Type:
logic LI1, LI2, BOOST) stop, run and boost on start-up functions <= 8 mA 27 kOhm
Width:
45 mm
Ip Degree Of Protection:
IP20
Depth:
131 mm
Product Certifications:
B44.1-96/ASME A17.5 for starter wired to the motor delta terminal || UL || C-tick || CSA || CCC || GOST
China Rohs Regulation:
X
Discrete Output Voltage:
24 V 6...30 V) open collector logic
Assembly Style:
with heat sink
Motor Starter Type:
soft starter
Pollution Degree:
2 EN/IEC 60947-4-2
Starting Time:
adjustable from 1 to 10 s || 1 s / 50 || 10 s / 5 || 5 s / 10
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Icl Starter Rating:
32 A
Ambient Air Temperature For Storage:
-25-70 °C EN/IEC 60947-4-2
Standards:
EN/IEC 60947-4-2
Phase:
3 phase
Shock Resistance:
15 gn 11 ms EN/IEC 60068-2-27
Minimum Switching Current:
10 mA 6 V DC relay outputs
  • Schneider Electric ATS01N232LU Soft-Start Stop 32A 200 240V
  • Schneider Electric ATS01N232LU Soft-Start Stop 32A 200 240V
$360.00

Description

This Altistart 01 soft starter is DIN rail mounted and can feed 3-phase asynchronous motors with a rating up to 32A. This Altistart 01 can be used for a motor rated power up to 7.5kW or 10hp for 3-phase (200V to 240V AC). This DIN rail mounted soft starter is designed to enable smooth start for simple machines such as conveyors, conveyor belts, pumps, fans, compressors, automatic doors and gates, small cranes and belt-driven machinery. It is 45mm wide, this makes it one of the smallest soft starters on the market; it can be installed nearly everywhere. It features an Integrated bypass, this reduces noise and decreases heat dissipation. Simple setup with only 2 settings: possible to configure by non-specialists. It provides smooth starting for your machinery, avoiding mechanical stresses and extending their service life.