Schneider Electric ATS22C14Q Electronic Soft Starter Control 220V Pow
Schneider Electric
$2,688.00
This Altistart 22 soft starter can feed 3-phase asynchronous motors in supply line or delta connection. It has a rating of 140A and 230V to 440V, a rated power up to 75kW (400V to 440V in supply line) and up to 110kW (400V to 440V in motor delta connection). It is designed for simple and complex machines such as centrifugal and piston pumps, fans, screw compressors and material handling equipment. Slim form factor improves versatility; allows mounting in frames of any kind of machines. It features an Integrated bypass, this reduces noise and decreases heat dissipation. Compatibility with SoMove software allows configurations and settings to be easily transferred, meaning spares can be quickly installed. It provides smooth starting for your machinery, avoiding mechanical stresses and extending their service life.
- Communication Port Protocol:
- Modbus
- Type Of Start:
- start with torque control (current limited to 3.5 In)
- Depth:
- 229.5 mm
- Function Available:
- internal bypass
- Range Of Product:
- Altistart 22
- Installed Device:
- 31
- Connector Type:
- 1 RJ45
- Assembly Style:
- with heat sink
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Component Name:
- ATS22
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Standards:
- IEC 60947-4-2
- Transmission Rate:
- 4800, 9600 or 19200 bps
- Utilisation Category:
- AC-53A
- Mercury Free:
- Yes
- Minimum Switching Current:
- 100 mA 12 V DC relay outputs)
- Phase:
- 3 phase
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Vibration Resistance:
- 1 gn 13-200 Hz)IEC 60068-2-6 || 1.5 mm 2-13 Hz)IEC 60068-2-6
- Discrete Output Number:
- 2
- Factory Setting Current:
- 131 A
- Operating Position:
- vertical +/- 10 degree
- Device Connection:
- in the motor supply line || to the motor delta terminals
- Power Range:
- 30-50 kW 200-240 V 3 phase || 55-100 kW 380-440 V 3 phase
- Product Certifications:
- UL || CSA || C-tick || GOST || CCC
- Marking:
- CE
- Product Specific Application:
- pumps and fans
- Product Destination:
- asynchronous motors
- Operating Altitude:
- <= 3280.84 ft (1000 m) without derating || > 3280.84...< 6561.68 ft (> 1000...< 2000 m) with current derating of 2.2 % per additional 100 m
- China Rohs Regulation:
- X
- Net Weight:
- 18 kg
- Motor Starter Type:
- soft starter
- Relative Humidity:
- 0-95 % without condensation or dripping water IEC 60068-2-3
- Discrete Input Voltage:
- 24 V <= 30 V
- Supply Voltage Limits:
- 195-484 V
- Ip Degree Of Protection:
- IP00
- Network Frequency:
- 45...66 Hz
- Ambient Air Temperature For Storage:
- -25-70 °C
- Noise Level:
- 56 dB
- Ambient Air Temperature For Operation:
- -10-40 °C without derating) || 40-60 °C with current derating 2.2 % per °C)
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Protection Type:
- phase failure line || thermal protection motor || thermal protection starter
- Discrete Output Type:
- relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O || relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O
- Output Current:
- 0.4...1 Icl adjustable
- Icl Starter Rating:
- 140 A connection in the motor supply line for standard applications
- Supply Frequency:
- 50...60 Hz - 10...10 %
- Communication Data Link:
- serial
- [Uc] Control Circuit Voltage:
- 230 V - 15...10 % 50/60 Hz
- Warranty:
- 18 months
- Discrete Input Logic:
- positive logic LI1, LI2, LI3 < 5 V <= 2 mA > 11 V, >= 5 mA
- Maximum Switching Current:
- 5 A 250 V AC resistive 1 relay outputs || 5 A 30 V DC resistive 1 relay outputs || 2 A 250 V AC inductive 0.4 20 ms relay outputs || 2 A 30 V DC inductive 7 ms relay outputs
- Width:
- 150 mm
- [Us] Rated Supply Voltage:
- 230...440 V - 15...10 %
- Rohs Exemption Information:
- Yes
- Electromagnetic Compatibility:
- conducted and radiated emissions level A IEC 60947-4-2 || damped oscillating waves level 3 IEC 61000-4-12 || electrostatic discharge level 3 IEC 61000-4-2 || immunity to electrical transients level 4 IEC 61000-4-4 || immunity to radiated radio-electr
- Type Of Cooling:
- forced convection
- Shock Resistance:
- 15 gn 11 ms IEC 60068-2-27
- Product Or Component Type:
- soft starter
- Control Circuit Consumption:
- 20 W
- Height:
- 356 mm
- Discrete Input Type:
- LI1, LI2, LI3) logic, 5 mA 4.3 kOhm
- Ptc Probe Input:
- 750 Ohm
- Motor Power Kw:
- 37 kW 230 V || 75 kW 400 V || 75 kW 440 V
- Pollution Degree:
- level 2 IEC 60664-1
- Physical Interface:
- RS485 multidrop
- Power Dissipation In W:
- 82 W for standard applications
- Discrete Input Number:
- 3
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View