Schneider Electric ATS22D32Q Soft Starter 32A 440V 220V Ctrl
Schneider Electric
$981.00
This soft starter can feed 3-phase asynchronous motors in supply line or delta connection. It has a rating of 32A and 230V to 440V, a rated power up to 15kW (400V to 440V in supply line) and up to 22kW (400V to 440V in motor delta connection). It is designed for simple and complex machines such as centrifugal and piston pumps, fans, screw compressors and material handling equipment. Slim form factor improves versatility; allows mounting in frames of any kind of machines. It features an Integrated bypass, this reduces noise and decreases heat dissipation. Compatibility with SoMove software allows configurations and settings to be easily transferred, meaning spares can be quickly installed. It provides smooth starting for your machinery, avoiding mechanical stresses and extending their service life.
- Communication Data Link:
- serial
- Output Current:
- 0.4...1 Icl adjustable
- Operating Position:
- vertical +/- 10 degree
- Network Frequency:
- 45...66 Hz
- Depth:
- 169 mm
- Vibration Resistance:
- 1 gn 13-200 Hz)IEC 60068-2-6 || 1.5 mm 2-13 Hz)IEC 60068-2-6
- Motor Starter Type:
- soft starter
- Discrete Input Type:
- LI1, LI2, LI3) logic, 5 mA 4.3 kOhm
- Product Destination:
- asynchronous motors
- Communication Port Protocol:
- Modbus
- Physical Interface:
- RS485 multidrop
- Ip Degree Of Protection:
- IP20
- Standards:
- IEC 60947-4-2
- Power Range:
- 7-11 kW 200-240 V 3 phase || 15-25 kW 380-440 V 3 phase
- Product Or Component Type:
- soft starter
- Ptc Probe Input:
- 750 Ohm
- Assembly Style:
- with heat sink
- Utilisation Category:
- AC-53A
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- [Us] Rated Supply Voltage:
- 230...440 V - 15...10 %
- Discrete Output Number:
- 2
- Electromagnetic Compatibility:
- conducted and radiated emissions level A IEC 60947-4-2 || damped oscillating waves level 3 IEC 61000-4-12 || electrostatic discharge level 3 IEC 61000-4-2 || immunity to electrical transients level 4 IEC 61000-4-4 || immunity to radiated radio-electr
- Shock Resistance:
- 15 gn 11 ms IEC 60068-2-27
- Product Specific Application:
- pumps and fans
- Noise Level:
- 45 dB
- Maximum Switching Current:
- 5 A 250 V AC resistive 1 relay outputs || 5 A 30 V DC resistive 1 relay outputs || 2 A 250 V AC inductive 0.4 20 ms relay outputs || 2 A 30 V DC inductive 7 ms relay outputs
- Device Connection:
- in the motor supply line || to the motor delta terminals
- Rohs Exemption Information:
- Yes
- Supply Voltage Limits:
- 195-484 V
- Mercury Free:
- Yes
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Discrete Input Logic:
- positive logic LI1, LI2, LI3 < 5 V <= 2 mA > 11 V, >= 5 mA
- China Rohs Regulation:
- X
- Installed Device:
- 31
- Icl Starter Rating:
- 32 A connection in the motor supply line for standard applications
- Factory Setting Current:
- 28.5 A
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Discrete Output Type:
- relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O || relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O
- [Uc] Control Circuit Voltage:
- 230 V - 15...10 % 50/60 Hz
- Minimum Switching Current:
- 100 mA 12 V DC relay outputs)
- Product Certifications:
- GOST || C-tick || UL || CCC || CSA
- Transmission Rate:
- 4800, 9600 or 19200 bps
- Protection Type:
- phase failure line || thermal protection motor || thermal protection starter
- Width:
- 130 mm
- Warranty:
- 18 months
- Component Name:
- ATS22
- Net Weight:
- 7 kg
- Height:
- 265 mm
- Relative Humidity:
- 0-95 % without condensation or dripping water IEC 60068-2-3
- Control Circuit Consumption:
- 20 W
- Power Dissipation In W:
- 44 W for standard applications
- Discrete Input Voltage:
- 24 V <= 30 V
- Ambient Air Temperature For Operation:
- -10-40 °C without derating) || 40-60 °C with current derating 2.2 % per °C)
- Function Available:
- internal bypass
- Pollution Degree:
- level 2 IEC 60664-1
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Marking:
- CE
- Motor Power Kw:
- 15 kW 400 V || 15 kW 440 V || 7.5 kW 230 V
- Ambient Air Temperature For Storage:
- -25-70 °C
- Connector Type:
- 1 RJ45
- Operating Altitude:
- <= 3280.84 ft (1000 m) without derating || > 3280.84...< 6561.68 ft (> 1000...< 2000 m) with current derating of 2.2 % per additional 100 m
- Discrete Input Number:
- 3
- Phase:
- 3 phase
- Supply Frequency:
- 50...60 Hz - 10...10 %
- Type Of Cooling:
- forced convection
- Range Of Product:
- Altistart 22
- Type Of Start:
- start with torque control (current limited to 3.5 In)
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View