Schneider Electric ATS22D62Q Soft Starter 62A 440V 230V Ctrl
Schneider Electric
$1,417.50
This soft starter can feed 3-phase asynchronous motors in supply line or delta connection. It has a rating of 62A and 230V to 440V, a rated power up to 30kW (400V to 440V in supply line) and up to 55kW (400V to 440V in motor delta connection). It is designed for simple and complex machines such as centrifugal and piston pumps, fans, screw compressors and material handling equipment. Slim form factor improves versatility; allows mounting in frames of any kind of machines. It features an Integrated bypass, this reduces noise and decreases heat dissipation. Compatibility with SoMove software allows configurations and settings to be easily transferred, meaning spares can be quickly installed. It provides smooth starting for your machinery, avoiding mechanical stresses and extending their service life.
- Motor Power Kw:
- 15 kW 230 V || 30 kW 400 V || 30 kW 440 V
- Network Frequency:
- 45...66 Hz
- Product Certifications:
- C-tick || CCC || UL || CSA || GOST
- Transmission Rate:
- 4800, 9600 or 19200 bps
- Communication Port Protocol:
- Modbus
- Ip Degree Of Protection:
- IP20
- Discrete Input Logic:
- positive logic LI1, LI2, LI3 < 5 V <= 2 mA > 11 V, >= 5 mA
- Discrete Input Number:
- 3
- Minimum Switching Current:
- 100 mA 12 V DC relay outputs)
- Shock Resistance:
- 15 gn 11 ms IEC 60068-2-27
- Physical Interface:
- RS485 multidrop
- Discrete Input Voltage:
- 24 V <= 30 V
- Output Current:
- 0.4...1 Icl adjustable
- Supply Voltage Limits:
- 195-484 V
- Net Weight:
- 12 kg
- Factory Setting Current:
- 57 A
- Communication Data Link:
- serial
- Product Or Component Type:
- soft starter
- Phase:
- 3 phase
- Warranty:
- 18 months
- Range Of Product:
- Altistart 22
- China Rohs Regulation:
- X
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Connector Type:
- 1 RJ45
- Electromagnetic Compatibility:
- conducted and radiated emissions level A IEC 60947-4-2 || damped oscillating waves level 3 IEC 61000-4-12 || electrostatic discharge level 3 IEC 61000-4-2 || immunity to electrical transients level 4 IEC 61000-4-4 || immunity to radiated radio-electr
- Relative Humidity:
- 0-95 % without condensation or dripping water IEC 60068-2-3
- Product Destination:
- asynchronous motors
- Vibration Resistance:
- 1 gn 13-200 Hz)IEC 60068-2-6 || 1.5 mm 2-13 Hz)IEC 60068-2-6
- Component Name:
- ATS22
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Product Specific Application:
- pumps and fans
- Utilisation Category:
- AC-53A
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Noise Level:
- 45 dB
- Power Range:
- 15-25 kW 200-240 V 3 phase || 30-50 kW 380-440 V 3 phase
- [Uc] Control Circuit Voltage:
- 230 V - 15...10 % 50/60 Hz
- Ptc Probe Input:
- 750 Ohm
- Pollution Degree:
- level 2 IEC 60664-1
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Motor Starter Type:
- soft starter
- Type Of Cooling:
- forced convection
- Maximum Switching Current:
- 5 A 250 V AC resistive 1 relay outputs || 5 A 30 V DC resistive 1 relay outputs || 2 A 250 V AC inductive 0.4 20 ms relay outputs || 2 A 30 V DC inductive 7 ms relay outputs
- Assembly Style:
- with heat sink
- Ambient Air Temperature For Storage:
- -25-70 °C
- Supply Frequency:
- 50...60 Hz - 10...10 %
- Control Circuit Consumption:
- 20 W
- Installed Device:
- 31
- Operating Position:
- vertical +/- 10 degree
- Icl Starter Rating:
- 62 A connection in the motor supply line for standard applications
- Mercury Free:
- Yes
- Type Of Start:
- start with torque control (current limited to 3.5 In)
- Rohs Exemption Information:
- Yes
- Discrete Output Type:
- relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O || relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O
- Power Dissipation In W:
- 59 W for standard applications
- Function Available:
- internal bypass
- [Us] Rated Supply Voltage:
- 230...440 V - 15...10 %
- Operating Altitude:
- <= 3280.84 ft (1000 m) without derating || > 3280.84...< 6561.68 ft (> 1000...< 2000 m) with current derating of 2.2 % per additional 100 m
- Protection Type:
- phase failure line || thermal protection motor || thermal protection starter
- Marking:
- CE
- Ambient Air Temperature For Operation:
- -10-40 °C without derating) || 40-60 °C with current derating 2.2 % per °C)
- Discrete Input Type:
- LI1, LI2, LI3) logic, 5 mA 4.3 kOhm
- Standards:
- IEC 60947-4-2
- Width:
- 145 mm
- Discrete Output Number:
- 2
- Depth:
- 207 mm
- Device Connection:
- to the motor delta terminals || in the motor supply line
- Height:
- 295 mm
- Brochure:
- View
- Catalog:
- View
- Datasheet: