Schneider Electric ATS480C59Y Soft Starter Ats480 590A 208 To 690V

(No reviews yet) Write a Review
SKU:
ATS480C59Y
UPC:
3606481089151
Condition:
New
Relative Humidity:
0-95 % without condensation or dripping water IEC 60068-2-3
Analogue Output Number:
1
Data Format:
8 bits, configurable odd, even or no parity
Discrete Input Number:
4
Circularity Profile:
ENVEOLI2102013EN
Number Of Addresses:
0-227 Modbus serial
Transmission Frame:
RTU
[Ie] Rated Operational Current:
normal duty 590.0 A 40 °C)
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || > 3280.84...13123.36 ft (> 1000...4000 m) with current derating 1 % per 100 m
Environmental Disclosure:
ENVPEP2102013EN
[In] Rated Current Pwr Loss Specifctn:
590.0 A
China Rohs Regulation:
X
Ambient Air Temperature For Storage:
-25-70 °C
Pollution Degree:
level 3
[Ui] Rated Insulation Voltage:
690 V
Power Loss Per Device Current Dependent:
1711.0 W
Device Connection:
in the motor supply line || to the motor delta terminals
Supply Frequency:
50...60 Hz - 20...20 %
Width:
400.0 mm
Product Certifications:
CE || cULus || CCC || UKCA || RCM || EAC || DNV || ABS || BV || CCS
Discrete Input Logic:
programmable digital input < 5 V
Device Short Name:
ATS480
Sustainable Offer Status:
Green Premium product
Maximum Switching Current:
relay outputs 2 A 250 V AC || relay outputs 2 A 30 V DC || relay outputs
Transmission Rate:
1200...256000 bit/s
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Electromagnetic Compatibility:
conducted and radiated emissions level A IEC 60947-4-2 || conducted and radiated emissions with bypass level B IEC 60947-4-2 || damped oscillating waves level 3 IEC 61000-4-12 || electrostatic discharge level 3 IEC 61000-4-11 || immunity to electrica
Utilisation Category:
AC-3A || AC-53A
Integrated Motor Overload Protection:
TRUE
Discrete Input Type:
STOP) logic inputs, 3500 Ohm || RUN) logic inputs, 3500 Ohm || DI3) programmable as logic input, 3500 Ohm || DI4) programmable as logic input, 3500 Ohm
Analogue Output Type:
current output AQ1 0...20 mA or 0...10 V 500 Ohm
Relay Output Type:
relay outputs R1A 1 NO || relay outputs R1B 1 NO || relay outputs RIC NO/NC programmable
Discrete Output Number:
2
[Us] Rated Supply Voltage:
208...690 V - 15...10 %
Physical Interface:
2-wire RS 485
Upgradeability:
Upgraded components available
Product Specific Application:
process and infrastructures
Apparent Power:
0.125 kVA
Maximum Horse Power Rating:
150.0 hp 208 V heavy duty || 200.0 hp 230 V normal duty || 400.0 hp 460 V normal duty || 350.0 hp 460 V heavy duty || 500.0 hp 575 V normal duty || 400.0 hp 575 V heavy duty
Maximum Deflection Under Vibratory Load (During Operation):
1.5 mm at 2...13 Hz
Analogue Input Number:
1
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Height:
670.0 mm
Maximum Deflection Under Vibratory Load (During Transport):
1.75 mm at 2...9 Hz
Discrete Output Type:
DQ1) programmable digital output <= 30 V || DQ2) programmable digital output <= 30 V
Minimum Switching Current:
100 mA 12 V DC relay outputs
Ip Degree Of Protection:
IP00
Maximum Acceleration Under Vibratory Load (During Storage):
15 m/s² at 200...500 Hz || 10 m/s² at 9...200 Hz
Function Available:
external bypass control || pre-heating || smoke extraction || multi-motor cascade || second motor set || user management || ports and services hardening || security event logging || cybersecure firmware update || single direction
Range Of Product:
Altivar Soft Starter ATS480
Operating Position:
vertical +/- 10 degree
Maximum Acceleration Under Shock Load (During Transport):
100 m/s² at 11 ms
Rohs Exemption Information:
Yes
Marking:
CE || CCC || UKCA || EAC || RCM || cULus
Product Or Component Type:
soft starter
Connector Type:
1 RJ45
Depth:
314.0 mm
Maximum Acceleration Under Vibratory Load (During Transport):
15 m/s² at 200...500 Hz || 10 m/s² at 9...200 Hz
Mercury Free:
Yes
Communication Port Protocol:
Modbus serial
Environmental Class (During Operation):
class 3C3 according to IEC 60721-3-3 || class 3S2 according to IEC 60721-3-3
Method Of Access:
slave Modbus serial
Option Card:
communication module Profibus DP V1 || communication module PROFINET || communication module Modbus TCP/EtherNet/IP || communication module CANopen daisy chain || communication module CANopen Sub-D || communication module CANopen open style
Accuracy Class:
class 10E
Maximum Acceleration Under Vibrational Stress (During Operation):
10 m/s² at 13...200 Hz
Protection Type:
phase failure line || integrated thermal protection motor || thermal protection starter || current overload motor || underload motor || excessive starting time, locked rotor motor || motor phase loss motor || line supply phase loss line || line suppl
Net Weight:
51.4 kg
Ambient Air Temperature For Operation:
40-60 °C with current derating of 2 % per °C) || -15-40 °C without derating)
Standards:
IEC 60947-4-2 || UL 60947-4-2 || IEC 60664-1
Maximum Permanent Current:
480.0 A at 40 °C heavy duty
Maximum Acceleration Under Shock Impact (During Operation):
150 m/s² at 11 ms
[Uc] Control Circuit Voltage:
110...250 V AC 50/60 Hz - 15...10 %
Product Destination:
asynchronous motors
[Uimp] Rated Impulse Withstand Voltage:
6 kV
Maximum Acceleration Under Shock Load (During Storage):
100 m/s² at 11 ms
Torque Control:
TRUE
Motor Power Kw:
160.0 kW 230 V in the motor supply line normal duty || 132.0 kW 230 V in the motor supply line heavy duty || 315.0 kW 400 V in the motor supply line normal duty || 250.0 kW 400 V in the motor supply line heavy duty || 355.0 kW 440 V in the motor supp
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Phase:
3 phase
Relay Output Number:
3
Output Current Drift:
150-700 %
Display Screen Available:
TRUE
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Type Of Polarization:
no impedance Modbus serial
Maximum Deflection Under Vibratory Load (During Storage):
1.75 mm at 2...9 Hz
Power Loss Static Current Independent:
25.0 W
Datasheet:
View
  • Schneider Electric ATS480C59Y Soft Starter Ats480 590A 208 To 690V
  • Schneider Electric ATS480C59Y Soft Starter Ats480 590A 208 To 690V
$8,274.99

Description

Altivar Soft Starter ATS480 is intended to start and stop asynchronous motors supplied from 208V to 690V. It meets the requirements of the most demanding applications in normal and heavy duty. With an operational rated current of 590A in normal duty, it supplies motor from 160kW to 560kW according to mains voltage. Designed for digitization, connected, optimized to meet cybersecurity standard, it simplifies project execution and maximizes the availability of applications. Its torque control (TCS) masters acceleration and deceleration. It efficiently stops high inertia application thanks to the dynamic braking and DC injection. It could be connected in-line or inside the delta to reduce its operational current. The embedded test routine simplifies the commissioning inside the delta. Its dimensions are 400mm (width) x 314mm (depth) x 670mm (height) and it weighs 51,4kg. Altivar Soft Starter ATS480 is designed to address process, infrastructures and industrial machines. It conforms to IEC/EN60947-4-1. It is certified CE, cULus, UKCA, CCC, RCM, EAC, and Marine certified DNV, ABS, BV and CCS. Display terminals, remote mounting kit, communication modules are common with Altivar Drives. Line chokes, DNV kits are common with ATS48. ATS480 is compatible with ATS48, it has same footprint, fixing, torque control algorithm, I/O, menus… The integration of Altivar Soft Starter ATS480 in EcoStruxure drastically simplifies architecture selection, detailed design and execution in automation and electrical systems. It is a Green Premium product designed to take the environmental considerations beyond current directives and regulations, compliant with RoHS and REACH.