Schneider Electric

Schneider Electric ATS480D62Y Soft Starter Ats480 62A 208 To 690V

(No reviews yet) Write a Review
SKU:
ATS480D62Y
UPC:
3606481089045
Condition:
New
Pollution Degree:
level 3
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Ambient Air Temperature For Storage:
-25-70 °C
Utilisation Category:
AC-3A || AC-53A
[Uc] Control Circuit Voltage:
110...250 V AC 50/60 Hz - 15...10 %
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || > 3280.84...13123.36 ft (> 1000...4000 m) with current derating 1 % per 100 m
[Us] Rated Supply Voltage:
208...690 V - 15...10 %
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Analogue Output Type:
current output AQ1 0...20 mA or 0...10 V 500 Ohm
Connector Type:
1 RJ45
Maximum Acceleration Under Shock Load (During Transport):
100 m/s² at 11 ms
Range Of Product:
Altivar Soft Starter ATS480
Integrated Motor Overload Protection:
TRUE
Upgradeability:
Upgraded components available
Relay Output Type:
relay outputs R1A 1 NO || relay outputs R1B 1 NO || relay outputs RIC NO/NC programmable
Discrete Output Number:
2
Maximum Permanent Current:
47.0 A at 40 °C heavy duty
Discrete Input Number:
4
China Rohs Regulation:
X
Display Screen Available:
TRUE
Maximum Acceleration Under Shock Impact (During Operation):
150 m/s² at 11 ms
Maximum Horse Power Rating:
15.0 hp 208 V normal duty || 20.0 hp 230 V normal duty || 15.0 hp 230 V heavy duty || 40.0 hp 460 V normal duty || 30.0 hp 460 V heavy duty || 50.0 hp 575 V normal duty || 40.0 hp 575 V heavy duty
Motor Power Kw:
15.0 kW 230 V in the motor supply line normal duty || 11.0 kW 230 V in the motor supply line heavy duty || 30.0 kW 400 V in the motor supply line normal duty || 22.0 kW 400 V in the motor supply line heavy duty || 30.0 kW 440 V in the motor supply li
Maximum Switching Current:
relay outputs 2 A 250 V AC || relay outputs 2 A 30 V DC
Power Loss Static Current Independent:
25.0 W
Output Current Drift:
150-700 %
Phase:
3 phase
Minimum Switching Current:
100 mA 12 V DC relay outputs
Analogue Input Number:
1
Function Available:
external bypass control || pre-heating || smoke extraction || multi-motor cascade || second motor set || user management || ports and services hardening || security event logging || cybersecure firmware update || single direction
Device Short Name:
ATS480
Transmission Frame:
RTU
Product Destination:
asynchronous motors
Type Of Polarization:
no impedance Modbus serial
Product Certifications:
CE || cULus || CCC || UKCA || RCM || EAC || DNV || ABS || BV || CCS
Electromagnetic Compatibility:
conducted and radiated emissions level A IEC 60947-4-2 || conducted and radiated emissions with bypass level B IEC 60947-4-2 || damped oscillating waves level 3 IEC 61000-4-12 || electrostatic discharge level 3 IEC 61000-4-11 || immunity to electrica
Communication Port Protocol:
Modbus serial
Supply Frequency:
50...60 Hz - 20...20 %
[Uimp] Rated Impulse Withstand Voltage:
6 kV
Height:
290.0 mm
Environmental Disclosure:
ENVPEP2009021EN
Protection Type:
phase failure line || integrated thermal protection motor || thermal protection starter || current overload motor || underload motor || excessive starting time, locked rotor motor || motor phase loss motor || line supply phase loss line || line suppl
Maximum Acceleration Under Vibratory Load (During Transport):
15 m/s² at 200...500 Hz || 10 m/s² at 9...200 Hz
Product Specific Application:
process and infrastructures
Width:
190.0 mm
Circularity Profile:
ENVEOLI2009021EN
Discrete Input Logic:
programmable digital input < 5 V
Mercury Free:
Yes
Sustainable Offer Status:
Green Premium product
[Ui] Rated Insulation Voltage:
690 V
Accuracy Class:
class 10E
Rohs Exemption Information:
Yes
Discrete Output Type:
DQ1) programmable digital output <= 30 V || DQ2) programmable digital output <= 30 V
Operating Position:
vertical +/- 10 degree
Data Format:
8 bits, configurable odd, even or no parity
Torque Control:
TRUE
Maximum Deflection Under Vibratory Load (During Storage):
1.75 mm at 2...9 Hz
Ip Degree Of Protection:
IP20
Number Of Addresses:
0-227 Modbus serial
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Relative Humidity:
0-95 % without condensation or dripping water IEC 60068-2-3
Power Loss Per Device Current Dependent:
181.0 W
Depth:
247.0 mm
Environmental Class (During Operation):
class 3C3 according to IEC 60721-3-3 || class 3S2 according to IEC 60721-3-3
Device Connection:
in the motor supply line || to the motor delta terminals
Product Or Component Type:
soft starter
Marking:
CE || CCC || UKCA || EAC || RCM || cULus
Discrete Input Type:
STOP) logic inputs, 3500 Ohm || RUN) logic inputs, 3500 Ohm || DI3) programmable as logic input, 3500 Ohm || DI4) programmable as logic input, 3500 Ohm
Option Card:
communication module Profibus DP V1 || communication module PROFINET || communication module Modbus TCP/EtherNet/IP || communication module CANopen daisy chain || communication module CANopen Sub-D || communication module CANopen open style
Relay Output Number:
3
Maximum Deflection Under Vibratory Load (During Operation):
1.5 mm at 2...13 Hz
Method Of Access:
slave Modbus serial
Physical Interface:
2-wire RS 485
Net Weight:
8.3 kg
Transmission Rate:
1200...256000 bit/s
Standards:
IEC 60947-4-2 || UL 60947-4-2 || IEC 60664-1
[In] Rated Current Pwr Loss Specifctn:
62.0 A
Analogue Output Number:
1
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Ambient Air Temperature For Operation:
40-60 °C with current derating of 2 % per °C) || -15-40 °C without derating)
Apparent Power:
0.09 kVA
Maximum Acceleration Under Vibrational Stress (During Operation):
10 m/s² at 13...200 Hz
[Ie] Rated Operational Current:
normal duty 62.0 A 40 °C)
Maximum Acceleration Under Shock Load (During Storage):
100 m/s² at 11 ms
Maximum Deflection Under Vibratory Load (During Transport):
1.75 mm at 2...9 Hz
Maximum Acceleration Under Vibratory Load (During Storage):
15 m/s² at 200...500 Hz || 10 m/s² at 9...200 Hz
Datasheet:
View
$1,713.74

Description

Altivar Soft Starter ATS480 is intended to start and stop asynchronous motors supplied from 208V to 690V. It meets the requirements of the most demanding applications in normal and heavy duty. With an operational rated current of 62A in normal duty, it supplies motor from 15kW to 45kW according to mains voltage. Designed for digitization, connected, optimized to meet cybersecurity standard, it simplifies project execution and maximizes the availability of applications. Its torque control (TCS) masters acceleration and deceleration. It efficiently stops high inertia application thanks to the dynamic braking and DC injection. It could be connected in-line or inside the delta to reduce its operational current. The embedded test routine simplifies the commissioning inside the delta. Its dimensions are 190mm (width) x 247mm (depth) x 290mm (height) and it weighs 8,3kg. Altivar Soft Starter ATS480 is designed to address process, infrastructures and industrial machines. It conforms to IEC/EN60947-4-1. It is certified CE, cULus, UKCA, CCC, RCM, EAC, and Marine certified DNV, ABS, BV and CCS. Display terminals, remote mounting kit, communication modules are common with Altivar Drives. Line chokes, DNV kits are common with ATS48. ATS480 is compatible with ATS48, it has same footprint, fixing, torque control algorithm, I/O, menus… The integration of Altivar Soft Starter ATS480 in EcoStruxure drastically simplifies architecture selection, detailed design and execution in automation and electrical systems. It is a Green Premium product designed to take the environmental considerations beyond current directives and regulations, compliant with RoHS and REACH.
View AllClose