Schneider Electric

Schneider Electric ATV212W075N4 Atv212 0,75Kw 1Hp 480V Tri Cem Ip55

(No reviews yet) Write a Review
SKU:
ATV212W075N4
UPC:
3606480322655
Condition:
New
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Ambient Air Temperature For Storage:
-25-70 °C
Emc Filter:
Class C2 EMC filter integrated
Connector Type:
1 open style || 1 RJ45
Product Or Component Type:
variable speed drive
Supply:
internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection || internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection
Maximum Switching Current:
5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R) || 5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R) || 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R) || 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R)
Relative Humidity:
5-95 % without condensation IEC 60068-2-3 || 5-95 % without dripping water IEC 60068-2-3
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Dielectric Strength:
3535 V DC between earth and power terminals || 5092 V DC between control and power terminals
Speed Accuracy:
+/- 10 % of nominal slip 0.2 Tn to Tn
Network Frequency:
47.5...63 Hz
Output Voltage:
<= power supply voltage
Product Certifications:
CSA || UL || C-tick || NOM 117
Functionality:
mid
Electrical Connection:
VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 2.5-2.5 mm² / AWG 14 || L1/R, L2/S, L3/T terminal 6-6 mm² / AWG 10
Braking To Standstill:
by DC injection
Analogue Output Type:
FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits || FM switch-configurable current 0...20 mA 970 Ohm 10 bits
Sampling Duration:
2 ms +/- 0.5 ms F discrete || 2 ms +/- 0.5 ms R discrete || 2 ms +/- 0.5 ms RES discrete || 3.5 ms +/- 0.5 ms VIA analog || 22 ms +/- 0.5 ms VIB analog
Isolation:
electrical between power and control
Operating Altitude:
3280.84...9842.52 ft (1000...3000 m) limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m || <= 3280.84 ft (1000 m) without derating
Transient Overtorque:
120-120 % of nominal motor torque +/- 10 % 60 s
Ip Degree Of Protection:
IP55 IEC 61800-5-1 || IP55 IEC 60529
Phase:
3 phase
Warranty:
18 months
Sustainable Offer Status:
Green Premium product
Motor Power Kw:
0.75 kW
Supply Voltage Limits:
323-528 V
Discrete Output Number:
2
Linearity Error:
VIA +/- 0.15 % of maximum value input || VIB +/- 0.15 % of maximum value input || FM +/- 0.2 % output
Continuous Output Current:
2.2 A 380 V || 2.2 A 460 V
Asynchronous Motor Control Profile:
voltage/frequency ratio, 2 points || voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) || voltage/frequency ratio - Energy Saving, quadratic U/f || flux vector control without sensor, standard || voltage/frequency ratio, 5 point
Local Signalling:
for DC bus energized 1 LED (red)
Product Destination:
asynchronous motors
Tightening Torque:
1.3 N.m, 11.5 lb.in L1/R, L2/S, L3/T) || 0.6 N.m VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES)
Environmental Disclosure:
ENVPEP111228EN
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01 to 3200 s || automatic based on the load
Depth:
192 mm
Physical Interface:
2-wire RS 485
Mercury Free:
Yes
Supply Frequency:
50...60 Hz - 5...5 %
Switching Frequency:
6...16 kHz adjustable || 12...16 kHz with derating factor
Height:
297 mm
Speed Drive Output Frequency:
0.5-200 Hz
Line Current:
1.4 A 480 V || 1.7 A 380 V
Frequency Resolution:
display unit 0.1 Hz || analog input 0.024/50 Hz
Response Time:
FM 2 ms +/- 0.5 ms analog || FLA, FLC 7 ms +/- 0.5 ms discrete || FLB, FLC 7 ms +/- 0.5 ms discrete || RY, RC 7 ms +/- 0.5 ms discrete
Vibration Resistance:
1.5 mm 3-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)EN/IEC 60068-2-8
Communication Port Protocol:
Modbus || BACnet || METASYS N2 || LonWorks || APOGEE FLN
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Width:
215 mm
Environmental Characteristic:
classes 3C1 IEC 60721-3-3 || classes 3S2 IEC 60721-3-3
Type Of Polarization:
no impedance
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Discrete Input Logic:
positive logic (source) F, R, RES), <= 5 V, >= 11 V || negative logic (sink) F, R, RES), >= 16 V, <= 10 V
Type Of Cable:
without mounting kit 1 IEC cable 45 °C, copper 90 °C / XLPE/EPR || without mounting kit 1 IEC cable 45 °C, copper 70 °C / PVC || with UL Type 1 kit 3 UL 508 cable 40 °C, copper 75 °C / PVC
Range Of Product:
Altivar 212
Prospective Line Isc:
5 kA
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Specific Application:
HVAC
Regulation Loop:
adjustable PI regulator
Pollution Degree:
2 IEC 61800-5-1
China Rohs Regulation:
X
Nominal Switching Frequency:
12 kHz
Operating Position:
vertical +/- 10 degree
Analogue Input Number:
2
Ambient Air Temperature For Operation:
-10-40 °C without derating) || 40-50 °C with derating factor)
Noise Level:
48 dB 86/188/EEC
Product Specific Application:
pumps and fans in HVAC
Transmission Rate:
9600 bps or 19200 bps
Insulation Resistance:
>= 1 mOhm 500 V DC for 1 minute
Standards:
IEC 61800-3 environments 2 category C1 || IEC 61800-5-1 || IEC 61800-3 environments 1 category C2 || IEC 61800-3 category C2 || IEC 61800-3 environments 2 category C2 || IEC 61800-3 environments 1 category C1 || IEC 61800-3 environments 1 category C3
Marking:
CE
Accuracy:
+/- 0.6 % VIA) for a temperature variation 60 °C || +/- 0.6 % VIB) for a temperature variation 60 °C || +/- 1 % FM) for a temperature variation 60 °C
Communication Service:
monitoring inhibitable || time out setting from 0.1 to 100 s || read device identification (43) || read holding registers (03) 2 words maximum || write multiple registers (16) 2 words maximum || write single register (06)
Discrete Input Type:
F programmable 24 V DC level 1 PLC 4700 Ohm || R programmable 24 V DC level 1 PLC 4700 Ohm || RES programmable 24 V DC level 1 PLC 4700 Ohm
Data Format:
8 bits, 1 stop, odd even or no configurable parity
Torque Accuracy:
+/- 15 %
Motor Slip Compensation:
automatic whatever the load || not available in voltage/frequency ratio motor control || adjustable
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Analogue Output Number:
1
Assembly Style:
with heat sink
Rohs Exemption Information:
Yes
Analogue Input Type:
VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable PTC probe 0...6 probes 1500 Ohm || VIA switch-configurable current 0...20 mA 250 Ohm 10 bits
Maximum Transient Current:
2.4 A 60 s
Transmission Frame:
RTU
Maximum Horse Power Rating:
1 hp
Discrete Output Type:
configurable relay logic FLA, FLC) NO - 100000 cycles || configurable relay logic FLB, FLC) NC - 100000 cycles || configurable relay logic RY, RC) NO - 100000 cycles
Speed Range:
45301
Net Weight:
7 kg
Number Of Addresses:
1-247
[Us] Rated Supply Voltage:
380...480 V - 15...10 %
Ip Degree Of Protection:
IP55
Protection Type:
overheating protection drive || thermal power stage drive || short-circuit between motor phases drive || input phase breaks drive || overcurrent between output phases and earth drive || overvoltages on the DC bus drive || break on the control circuit
Circularity Profile:
ENVEOLI111234EN
Option Card:
communication card LonWorks
Apparent Power:
1.6 kVA 380 V
Device Short Name:
ATV212
Minimum Switching Current:
3 mA 24 V DC configurable relay logic
Brochure:
View
Catalog:
View
Datasheet:
View
$857.01

Description

This Altivar 212 variable speed drive can feed 3-phase asynchronous motors. Its protection index is IP55 and it has a built-in EMC filter. It works at a rated power up to 0.75kW / 1hp and a rated voltage from 380V to 480V AC. Its design is based on eco-energy with a reduction in energy consumption of up to 70% compared to a conventional control system. Thanks to its cable temperature rise reduction technology, the Altivar 212 drive offers immediate, disturbance-free operation avoiding additional options such as a line choke or DC choke to deal with current harmonics. It weighs 7kg and its dimensions are, 215mm wide, 297mm high, 192mm deep. It is specifically designed for the most common fluid management applications in tertiary sector buildings (HVAC) like heating, ventilation, air conditioning and pumping. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, C-Tick and NOM certified. The Altivar 212 offers optional motor chokes which can increase the maximum cable lengths between the drive and the motor and limit disturbance at the motor terminals. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. The Altivar 212 drive can easily be adapted to all building management systems thanks to its numerous functions and communication protocols integrated as standard, Modbus, METASYS N2, APOGEE FLN P1 and BACnet.