Schneider Electric ATV212WU15N4 Atv212 1,5Kw 2Hp 480V Tri Cem Ip55
Schneider Electric
$963.96
This Altivar 212 variable speed drive can feed 3-phase asynchronous motors. Its protection index is IP55 and it has a built-in EMC filter. It works at a rated power up to 1.5kW / 2hp and a rated voltage from 380V to 480V AC. Its design is based on eco-energy with a reduction in energy consumption of up to 70% compared to a conventional control system. Thanks to its cable temperature rise reduction technology, the Altivar 212 drive offers immediate, disturbance-free operation avoiding additional options such as a line choke or DC choke to deal with current harmonics. It weighs 7kg and its dimensions are, 215mm wide, 297mm high, 192mm deep. It is specifically designed for the most common fluid management applications in tertiary sector buildings (HVAC) like heating, ventilation, air conditioning and pumping. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, C-Tick and NOM certified. The Altivar 212 offers optional motor chokes which can increase the maximum cable lengths between the drive and the motor and limit disturbance at the motor terminals. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. The Altivar 212 drive can easily be adapted to all building management systems thanks to its numerous functions and communication protocols integrated as standard, Modbus, METASYS N2, APOGEE FLN P1 and BACnet.
- Ambient Air Temperature For Storage:
- -25-70 °C
- Number Of Addresses:
- 1-247
- Maximum Switching Current:
- 5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R) || 5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R) || 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R) || 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R)
- Relative Humidity:
- 5-95 % without condensation IEC 60068-2-3 || 5-95 % without dripping water IEC 60068-2-3
- Sampling Duration:
- 2 ms +/- 0.5 ms F discrete || 2 ms +/- 0.5 ms R discrete || 2 ms +/- 0.5 ms RES discrete || 3.5 ms +/- 0.5 ms VIA analog || 22 ms +/- 0.5 ms VIB analog
- Speed Accuracy:
- +/- 10 % of nominal slip 0.2 Tn to Tn
- Analogue Input Type:
- VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable PTC probe 0...6 probes 1500 Ohm || VIA switch-configurable current 0...20 mA 250 Ohm 10 bits
- Product Or Component Type:
- variable speed drive
- Vibration Resistance:
- 1.5 mm 3-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)EN/IEC 60068-2-8
- Apparent Power:
- 2.8 kVA 380 V
- Depth:
- 192 mm
- Continuous Output Current:
- 3.7 A 380 V || 3.7 A 460 V
- Standards:
- IEC 61800-3 environments 1 category C1 || IEC 61800-3 environments 2 category C1 || IEC 61800-3 environments 1 category C3 || IEC 61800-5-1 || IEC 61800-3 environments 2 category C3 || IEC 61800-3 || IEC 61800-3 category C2 || EN 61800-3 category C3
- Operating Position:
- vertical +/- 10 degree
- Prospective Line Isc:
- 5 kA
- Product Certifications:
- UL || CSA || NOM 117 || C-tick
- Line Current:
- 2.5 A 480 V || 3.2 A 380 V
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Phase:
- 3 phase
- Asynchronous Motor Control Profile:
- voltage/frequency ratio, 5 points || voltage/frequency ratio - Energy Saving, quadratic U/f || flux vector control without sensor, standard || voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) || voltage/frequency ratio, 2 point
- Linearity Error:
- VIA +/- 0.15 % of maximum value input || VIB +/- 0.15 % of maximum value input || FM +/- 0.2 % output
- Dielectric Strength:
- 3535 V DC between earth and power terminals || 5092 V DC between control and power terminals
- Acceleration And Deceleration Ramps:
- linear adjustable separately from 0.01 to 3200 s || automatic based on the load
- Torque Accuracy:
- +/- 15 %
- Transmission Frame:
- RTU
- Speed Range:
- 45301
- Braking To Standstill:
- by DC injection
- Specific Application:
- HVAC
- [Us] Rated Supply Voltage:
- 380...480 V - 15...10 %
- Maximum Horse Power Rating:
- 2 hp
- Analogue Output Number:
- 1
- Data Format:
- 8 bits, 1 stop, odd even or no configurable parity
- Isolation:
- electrical between power and control
- Tightening Torque:
- 1.3 N.m, 11.5 lb.in L1/R, L2/S, L3/T) || 0.6 N.m VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES)
- Assembly Style:
- with heat sink
- Width:
- 215 mm
- Network Frequency:
- 47.5...63 Hz
- Analogue Output Type:
- FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits || FM switch-configurable current 0...20 mA 970 Ohm 10 bits
- Nominal Switching Frequency:
- 12 kHz
- Type Of Polarization:
- no impedance
- Speed Drive Output Frequency:
- 0.5-200 Hz
- Motor Slip Compensation:
- adjustable || not available in voltage/frequency ratio motor control || automatic whatever the load
- Communication Service:
- monitoring inhibitable || read holding registers (03) 2 words maximum || read device identification (43) || write multiple registers (16) 2 words maximum || time out setting from 0.1 to 100 s || write single register (06)
- Local Signalling:
- for DC bus energized 1 LED (red)
- Device Short Name:
- ATV212
- Transmission Rate:
- 9600 bps or 19200 bps
- Physical Interface:
- 2-wire RS 485
- Supply Voltage Limits:
- 323-528 V
- Switching Frequency:
- 6...16 kHz adjustable || 12...16 kHz with derating factor
- Type Of Cable:
- without mounting kit 1 IEC cable 45 °C, copper 90 °C / XLPE/EPR || without mounting kit 1 IEC cable 45 °C, copper 70 °C / PVC || with UL Type 1 kit 3 UL 508 cable 40 °C, copper 75 °C / PVC
- Product Specific Application:
- pumps and fans in HVAC
- Accuracy:
- +/- 0.6 % VIA) for a temperature variation 60 °C || +/- 0.6 % VIB) for a temperature variation 60 °C || +/- 1 % FM) for a temperature variation 60 °C
- Response Time:
- FM 2 ms +/- 0.5 ms analog || FLA, FLC 7 ms +/- 0.5 ms discrete || FLB, FLC 7 ms +/- 0.5 ms discrete || RY, RC 7 ms +/- 0.5 ms discrete
- Electromagnetic Compatibility:
- electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
- Rohs Exemption Information:
- Yes
- Environmental Characteristic:
- classes 3C1 IEC 60721-3-3 || classes 3S2 IEC 60721-3-3
- Frequency Resolution:
- display unit 0.1 Hz || analog input 0.024/50 Hz
- Electrical Connection:
- VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 2.5-2.5 mm² / AWG 14 || L1/R, L2/S, L3/T terminal 6-6 mm² / AWG 10
- Pollution Degree:
- 2 IEC 61800-5-1
- Option Card:
- communication card LonWorks
- Warranty:
- 18 months
- Emc Filter:
- Class C2 EMC filter integrated
- Insulation Resistance:
- >= 1 mOhm 500 V DC for 1 minute
- Net Weight:
- 7 kg
- Noise Level:
- 48 dB 86/188/EEC
- Maximum Transient Current:
- 4 A 60 s
- Functionality:
- mid
- Transient Overtorque:
- 120-120 % of nominal motor torque +/- 10 % 60 s
- Ambient Air Temperature For Operation:
- -10-40 °C without derating) || 40-50 °C with derating factor)
- Protection Type:
- overheating protection drive || thermal power stage drive || short-circuit between motor phases drive || input phase breaks drive || overcurrent between output phases and earth drive || overvoltages on the DC bus drive || break on the control circuit
- Connector Type:
- 1 open style || 1 RJ45
- Motor Power Kw:
- 1.5 kW
- Mercury Free:
- Yes
- Supply Frequency:
- 50...60 Hz - 5...5 %
- Height:
- 297 mm
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Output Voltage:
- <= power supply voltage
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Marking:
- CE
- Discrete Output Type:
- configurable relay logic FLA, FLC) NO - 100000 cycles || configurable relay logic FLB, FLC) NC - 100000 cycles || configurable relay logic RY, RC) NO - 100000 cycles
- Shock Resistance:
- 15 gn 11 ms IEC 60068-2-27
- Environmental Disclosure:
- ENVPEP111228EN
- Regulation Loop:
- adjustable PI regulator
- Communication Port Protocol:
- METASYS N2 || APOGEE FLN || Modbus || BACnet || LonWorks
- Ip Degree Of Protection:
- IP55
- Analogue Input Number:
- 2
- Discrete Input Logic:
- positive logic (source) F, R, RES), <= 5 V, >= 11 V || negative logic (sink) F, R, RES), >= 16 V, <= 10 V
- Supply:
- internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection || internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection
- Operating Altitude:
- 3280.84...9842.52 ft (1000...3000 m) limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m || <= 3280.84 ft (1000 m) without derating
- Ip Degree Of Protection:
- IP55 IEC 61800-5-1 || IP55 IEC 60529
- Range Of Product:
- Altivar 212
- Circularity Profile:
- ENVEOLI111234EN
- Product Destination:
- asynchronous motors
- Minimum Switching Current:
- 3 mA 24 V DC configurable relay logic
- Discrete Input Type:
- F programmable 24 V DC level 1 PLC 4700 Ohm || R programmable 24 V DC level 1 PLC 4700 Ohm || RES programmable 24 V DC level 1 PLC 4700 Ohm
- Sustainable Offer Status:
- Green Premium product
- Discrete Output Number:
- 2
- China Rohs Regulation:
- X
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View