Schneider Electric ATV212WU75N4 Atv212 7,5Kw 10Hp 480V Tri Cem Ip55

(No reviews yet) Write a Review
SKU:
ATV212WU75N4
UPC:
3.60648E+12
Condition:
New
Dielectric Strength:
3535 V DC between earth and power terminals || 5092 V DC between control and power terminals
Vibration Resistance:
1.5 mm 3-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)EN/IEC 60068-2-8
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Prospective Line Isc:
22 kA
Ambient Air Temperature For Operation:
-10-40 °C without derating) || 40-50 °C with derating factor)
Transient Overtorque:
120-120 % of nominal motor torque +/- 10 % 60 s
Noise Level:
55 dB 86/188/EEC
Isolation:
electrical between power and control
Assembly Style:
with heat sink
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Nominal Switching Frequency:
12 kHz
Discrete Input Type:
F programmable 24 V DC level 1 PLC 4700 Ohm || R programmable 24 V DC level 1 PLC 4700 Ohm || RES programmable 24 V DC level 1 PLC 4700 Ohm
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Circularity Profile:
ENVEOLI111234EN
Operating Position:
vertical +/- 10 degree
Device Short Name:
ATV212
Net Weight:
10.95 kg
Communication Service:
write multiple registers (16) 2 words maximum || read device identification (43) || write single register (06) || time out setting from 0.1 to 100 s || read holding registers (03) 2 words maximum || monitoring inhibitable
Product Specific Application:
pumps and fans in HVAC
Transmission Frame:
RTU
Sampling Duration:
2 ms +/- 0.5 ms F discrete || 2 ms +/- 0.5 ms R discrete || 2 ms +/- 0.5 ms RES discrete || 3.5 ms +/- 0.5 ms VIA analog || 22 ms +/- 0.5 ms VIB analog
Discrete Output Number:
2
Phase:
3 phase
Depth:
208 mm
Standards:
IEC 61800-3 environments 2 category C1 || IEC 61800-5-1 || IEC 61800-3 environments 1 category C2 || EN 61800-3 category C3 || IEC 61800-3 environments 1 category C3 || IEC 61800-3 category C2 || IEC 61800-3 environments 2 category C2 || IEC 61800-3
Rohs Exemption Information:
Yes
Emc Filter:
Class C2 EMC filter integrated
Transmission Rate:
9600 bps or 19200 bps
Number Of Addresses:
1-247
Mercury Free:
Yes
Functionality:
mid
Minimum Switching Current:
3 mA 24 V DC configurable relay logic
Accuracy:
+/- 0.6 % VIA) for a temperature variation 60 °C || +/- 0.6 % VIB) for a temperature variation 60 °C || +/- 1 % FM) for a temperature variation 60 °C
Specific Application:
HVAC
Motor Slip Compensation:
automatic whatever the load || adjustable || not available in voltage/frequency ratio motor control
Sustainable Offer Status:
Green Premium product
Protection Type:
overheating protection drive || thermal power stage drive || short-circuit between motor phases drive || input phase breaks drive || overcurrent between output phases and earth drive || overvoltages on the DC bus drive || break on the control circuit
Analogue Input Number:
2
Height:
340 mm
Ip Degree Of Protection:
IP55 IEC 61800-5-1 || IP55 IEC 60529
Type Of Cable:
without mounting kit 1 IEC cable 45 °C, copper 90 °C / XLPE/EPR || without mounting kit 1 IEC cable 45 °C, copper 70 °C / PVC || with UL Type 1 kit 3 UL 508 cable 40 °C, copper 75 °C / PVC
Maximum Horse Power Rating:
10 hp
Environmental Characteristic:
classes 3C1 IEC 60721-3-3 || classes 3S2 IEC 60721-3-3
[Us] Rated Supply Voltage:
380...480 V - 15...10 %
Discrete Input Logic:
positive logic (source) F, R, RES), <= 5 V, >= 11 V || negative logic (sink) F, R, RES), >= 16 V, <= 10 V
Speed Range:
45301
Marking:
CE
Physical Interface:
2-wire RS 485
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Product Or Component Type:
variable speed drive
Torque Accuracy:
+/- 15 %
Apparent Power:
12.2 kVA 380 V
Continuous Output Current:
16 A 380 V || 16 A 460 V
Asynchronous Motor Control Profile:
voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) || flux vector control without sensor, standard || voltage/frequency ratio, 5 points || voltage/frequency ratio, 2 points || voltage/frequency ratio - Energy Saving, quadratic U/
Insulation Resistance:
>= 1 mOhm 500 V DC for 1 minute
Ambient Air Temperature For Storage:
-25-70 °C
Product Destination:
asynchronous motors
Range Of Product:
Altivar 212
Environmental Disclosure:
ENVPEP111228EN
Response Time:
FM 2 ms +/- 0.5 ms analog || FLA, FLC 7 ms +/- 0.5 ms discrete || FLB, FLC 7 ms +/- 0.5 ms discrete || RY, RC 7 ms +/- 0.5 ms discrete
Type Of Polarization:
no impedance
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01 to 3200 s || automatic based on the load
Regulation Loop:
adjustable PI regulator
Tightening Torque:
0.6 N.m VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES) || 2.5 N.m, 22 lb.in L1/R, L2/S, L3/T)
Speed Drive Output Frequency:
0.5-200 Hz
Linearity Error:
VIA +/- 0.15 % of maximum value input || VIB +/- 0.15 % of maximum value input || FM +/- 0.2 % output
Operating Altitude:
3280.84...9842.52 ft (1000...3000 m) limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m || <= 3280.84 ft (1000 m) without derating
Warranty:
18 months
Communication Port Protocol:
BACnet || Modbus || LonWorks || METASYS N2 || APOGEE FLN
Supply:
internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection || internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection
Discrete Output Type:
configurable relay logic FLA, FLC) NO - 100000 cycles || configurable relay logic FLB, FLC) NC - 100000 cycles || configurable relay logic RY, RC) NO - 100000 cycles
Local Signalling:
for DC bus energized 1 LED (red)
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Frequency Resolution:
display unit 0.1 Hz || analog input 0.024/50 Hz
Electrical Connection:
VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 2.5-2.5 mm² / AWG 14 || L1/R, L2/S, L3/T terminal 16-16 mm² / AWG 6
Connector Type:
1 open style || 1 RJ45
Width:
230 mm
Line Current:
11.7 A 480 V || 14.7 A 380 V
Motor Power Kw:
7.5 kW
Switching Frequency:
6...16 kHz adjustable || 12...16 kHz with derating factor
Option Card:
communication card LonWorks
Pollution Degree:
3 IEC 61800-5-1
Product Certifications:
CSA || C-tick || NOM 117 || UL
Braking To Standstill:
by DC injection
Supply Frequency:
50...60 Hz - 5...5 %
Output Voltage:
<= power supply voltage
Analogue Output Number:
1
Data Format:
8 bits, 1 stop, odd even or no configurable parity
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Network Frequency:
47.5...63 Hz
Maximum Transient Current:
17.6 A 60 s
Supply Voltage Limits:
323-528 V
Ip Degree Of Protection:
IP55
Relative Humidity:
5-95 % without condensation IEC 60068-2-3 || 5-95 % without dripping water IEC 60068-2-3
Speed Accuracy:
+/- 10 % of nominal slip 0.2 Tn to Tn
China Rohs Regulation:
X
Analogue Input Type:
VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable PTC probe 0...6 probes 1500 Ohm || VIA switch-configurable current 0...20 mA 250 Ohm 10 bits
Maximum Switching Current:
5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R) || 5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R) || 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R) || 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R)
Analogue Output Type:
FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits || FM switch-configurable current 0...20 mA 970 Ohm 10 bits
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric ATV212WU75N4 Atv212 7,5Kw 10Hp 480V Tri Cem Ip55
  • Schneider Electric ATV212WU75N4 Atv212 7,5Kw 10Hp 480V Tri Cem Ip55
$1,677.91

Description

This Altivar 212 variable speed drive can feed 3-phase asynchronous motors. Its protection index is IP55 and it has a built-in EMC filter. It works at a rated power up to 7.5kW / 10hp and a rated voltage from 380V to 480V AC. Its design is based on eco-energy with a reduction in energy consumption of up to 70% compared to a conventional control system. Thanks to its cable temperature rise reduction technology, the Altivar 212 drive offers immediate, disturbance-free operation avoiding additional options such as a line choke or DC choke to deal with current harmonics. It weighs 10.95kg and its dimensions are, 230mm wide, 340mm high, 208mm deep. It is specifically designed for the most common fluid management applications in tertiary sector buildings (HVAC) like heating, ventilation, air conditioning and pumping. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, C-Tick and NOM certified. The Altivar 212 offers optional motor chokes which can increase the maximum cable lengths between the drive and the motor and limit disturbance at the motor terminals. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. The Altivar 212 drive can easily be adapted to all building management systems thanks to its numerous functions and communication protocols integrated as standard, Modbus, METASYS N2, APOGEE FLN P1 and BACnet.
View AllClose