Schneider Electric ATV340D18N4E Atv340 18,5Kw 25Hp 400V With Ethernet Va

(No reviews yet) Write a Review
SKU:
ATV340D18N4E
UPC:
3606480967078
Condition:
New
Connector Type:
3 RJ45
China Rohs Regulation:
X
Sustainable Offer Status:
Green Premium product
Maximum Output Frequency:
0.599 kHz
Nominal Switching Frequency:
4 kHz
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Analogue Output Number:
2
Maximum Acceleration Under Vibrational Stress (During Operation):
5 m/s² at 9...200 Hz
Pollution Degree:
2 IEC 61800-5-1
Analogue Input Type:
AI1 software-configurable current 0...20 mA 250 Ohm 12 bits || AI1 software-configurable temperature probe or water level sensor || AI1 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI2 software-configurable voltage - 10...10 V DC 31
Base Load Current At Low Overload:
46.0 A
Relay Output Number:
2
With Safety Function Safe Operating Stop (Sos):
FALSE
Volume Of Cooling Air:
128.0 m3/h
Pollution Degree:
2
Analogue Output Type:
software-configurable voltage AQ1 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1 0...20 mA 500 Ohm 10 bits
Switching Frequency:
2...16 kHz adjustable || 4...16 kHz with derating factor
With Safety Function Safe Speed Monitor (Ssm):
FALSE
Number Of Addresses:
1-247
Transmission Rate:
4.8 kbit/s || 9.6 kbit/s || 19.2 kbit/s || 38.4 kbit/s
Product Or Component Type:
variable speed drive
Minimum Switching Current:
relay output R1B 5 mA 24 V DC || relay output R2C 5 mA 24 V DC
Discrete Output Number:
2
With Safety Function Safely Limited Position (Slp):
FALSE
Method Of Access:
slave Modbus RTU || slave Modbus TCP
With Safety Function Safe Stop 1 (Ss1):
TRUE
Circularity Profile:
ENVEOLI1609006EN
With Safety Function Safe Direction (Sdi):
FALSE
Nominal Output Current:
39.0 A
Variant:
standard version
With Safety Function Safe Position (Sp):
FALSE
Ambient Air Transport Temperature:
-40-70 °C
Line Current:
54.7 A 380 V without line choke heavy duty) || 43.4 A 480 V without line choke heavy duty) || 49.9 A 380 V with external line choke normal duty) || 40.2 A 480 V with external line choke normal duty) || 54.5 A 480 V with external line choke heavy duty
With Sft Fct Safe Stop 2 (Ss2):
FALSE
Line Current:
43.4 A 380 V normal duty) || 35.0 A 480 V normal duty) || 54.7 A 380 V heavy duty) || 43.4 A 480 V heavy duty)
Braking To Standstill:
by DC injection
Maximum Acceleration Under Shock Impact (During Operation):
70 m/s² at 22 ms
Noise Level:
56.7 dB
With Safety Function Safely Limited Speed (Sls):
TRUE
Discrete Output Type:
programmable output DQ1, DQ2 30 V DC 100 mA
Prospective Line Isc:
22 kA
[Us] Rated Supply Voltage:
380...480 V - 15...10 %
Product Certifications:
UL || CSA || TÜV || EAC || CTick
Protection Type:
thermal protection motor || safe torque off motor || motor phase loss motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent drive || output overcurrent between motor phase and earth drive || output overcurrent
Apparent Power:
33.4 kVA 480 V normal duty) || 36.1 kVA 480 V heavy duty)
Product Specific Application:
machine
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Assembly Style:
with heat sink
Discrete Input Number:
5
Operating Altitude:
<= 9842.52 ft (3000 m) with current derating above 1000m
Data Format:
8 bits, configurable odd, even or no parity
Ambient Air Temperature For Operation:
-15-50 °C without derating vertical position) || 50-60 °C with derating factor vertical position)
Mercury Free:
Yes
Discrete Input Type:
PTI programmable as pulse input 0-30 kHz, 24 V DC 30 V) || DI1...DI5 safe torque off, 24 V DC 30 V)3.5 kOhm || programmable
Type Of Polarization:
no impedance
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
With Safety Function Safe Programmable Logic:
FALSE
Acceleration And Deceleration Ramps:
S, U or customized || linear adjustable separately from 0.01...9999 s
Output Voltage:
<= power supply voltage
Marking:
CE
Maximum Output Voltage:
480 V
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Supply Frequency:
50...60 Hz +/- 5 %
Maximum Switching Current:
relay output R1C resistive, cos phi = 1 3 A 250 V AC || relay output R1C resistive, cos phi = 1 3 A 30 V DC || relay output R1C inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1C inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R
Relay Output Type:
relay outputs R1A || relay outputs R1C 100000 cycles || relay outputs R2A || relay outputs R2C 100000 cycles
Analogue Input Number:
2
Range Of Product:
Altivar Machine ATV340
Ambient Air Temperature For Storage:
-40-70 °C
Emc Filter:
class C3 EMC filter integrated
Height:
385.0 mm
Physical Interface:
2-wire RS 485
Ip Degree Of Protection:
IP20
Power Dissipation In W:
natural convection 21 W 380 V 4 kHz heavy duty) || forced convection 410 W 380 V 4 kHz heavy duty) || natural convection 23 W 380 V 4 kHz normal duty) || forced convection 464 W 380 V 4 kHz normal duty)
Operating Position:
vertical +/- 10 degree
Electrical Connection:
control screw terminal 0.2...2.5 mm² AWG 24...AWG 12 || line side screw terminal 10...25 mm² AWG 8...AWG 3 || DC bus screw terminal 10...25 mm² AWG 8...AWG 3 || motor screw terminal 6...25 mm² AWG 8...AWG 3
Synchronous Motor Control Profile:
reluctance motor || permanent magnet motor
Upgradeability:
Upgraded components available
Isolation:
between power and control terminals
4 Quadrant Operation Possible:
TRUE
Phase:
3 phase
Electrical Connection:
screw terminal 0.2...2.5 mm² control || screw terminal 10...25 mm² line side || screw terminal 10...25 mm² DC bus || screw terminal 6...25 mm² motor
Base Load Current At High Overload:
39.0 A
Environmental Disclosure:
ENVPEP1609006EN
Continuous Output Current:
46 A 4 kHz normal duty || 39 A 4 kHz heavy duty
Transmission Frame:
RTU
Environmental Class (During Operation):
class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
Net Weight:
10.2 kg
With Safety Function Safe Torque Off (Sto):
TRUE
Permitted Relative Humidity (During Operation):
class 3K5 according to EN 60721-3
Motor Slip Compensation:
can be suppressed || adjustable || not available in permanent magnet motor law || automatic whatever the load
Maximum Deflection Under Vibratory Load (During Operation):
1.5 mm at 2...9 Hz
Maximum Horse Power Rating:
30 hp normal duty || 25 hp heavy duty
Type Of Cooling:
forced convection
Brake Chopper Integrated:
TRUE
Width:
180.0 mm
Maximum Transient Current:
50.6 A 60 s normal duty) || 59 A 60 s heavy duty) || 62.1 A 2 s normal duty) || 70 A 2 s heavy duty)
With Safety Function Safe Brake Management (Sbc/Sbt):
TRUE
Asynchronous Motor Control Profile:
variable torque standard || constant torque standard || optimized torque mode
Discrete Input Logic:
16 preset speeds
Mounting Mode:
cabinet mount
Rohs Exemption Information:
Yes
Standards:
IEC 61800-3 || IEC 61800-5-1 || IEC 60721-3 || IEC 61508 || IEC 13849-1 || UL 618000-5-1 || UL 508C
Motor Power Kw:
22 kW normal duty || 18.5 kW heavy duty
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Regulation Loop:
adjustable PID regulator
Depth:
249.0 mm
Communication Port Protocol:
EtherNet/IP || Modbus TCP || Modbus serial
Overvoltage Category:
class III
Brochure:
View
Catalog:
View
Datasheet:
View
$4,469.63

Description

This Altivar 340 variable speed drive can feed 3-phase synchronous and asynchronous motors in open and closed loop control. Altivar Machine ATV340 drives are sized heavy duty as standard. It works at a rated power up to 18.5kW / 25hp and a rated voltage from 380V to 480V AC. ATV340 has been designed to meet the needs of applications for harsh environments, such as vibration, shock and non-conductive dust and where high temperature resistance up to 60 °C is needed. This product integrates Modbus serial line communication protocols as standard. This drive features multi-protocol Ethernet embedded, it consists of Ethernet IP and Modbus TCP communication interfaces. it weighs 10.2kg and its dimensions are, 180mm wide, 385mm high, 249mm deep. ATV340 incorporates functions and features suitable for the most common applications, including packaging, material handling, material working, hoisting. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions), IEC 60721-3, IEC 61508, IEC 13849-1. It is also CE, UL, CSA, and TÜV certified. Accessories and options (encoder interface modules, I/O expansion modules, communication modules, braking resistors, line chokes, additional EMC filters) are available with Altivar Machine ATV340 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. It is fully integrated inside Schneider Electric’s EcoStruxure Machine through DTM. It is possible to configure, control, and diagnose ATV340 drives directly in SoMachine and SoMove software by means of the same software brick (DTM).
View AllClose