Schneider Electric ATV340D45N4E Atv340 45Kw 60Hp 400V With Ethernet Vari

(No reviews yet) Write a Review
SKU:
ATV340D45N4E
UPC:
3.61E+12
Condition:
New
Option Card:
communication module, PROFINET || communication module, DeviceNet || communication module, CANopen || communication module, EtherCAT
Nominal Switching Frequency:
2.5 kHz
With Safety Function Safe Stop 1 (Ss1):
TRUE
Depth:
309.0 mm
Maximum Output Frequency:
0.599 kHz
Discrete Input Number:
8
Apparent Power:
70 kVA 480 V normal duty) || 59.7 kVA 480 V heavy duty)
Product Certifications:
UL || CSA || TÜV || EAC || CTick
Maximum Horse Power Rating:
75 hp normal duty || 60 hp heavy duty
Environmental Class (During Operation):
class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
With Safety Function Safe Speed Monitor (Ssm):
FALSE
With Safety Function Safe Brake Management (Sbc/Sbt):
TRUE
Mounting Mode:
wall mount
With Safety Function Safe Torque Off (Sto):
TRUE
Ambient Air Temperature For Operation:
-15-50 °C without derating vertical position) || 50-60 °C with derating factor vertical position)
Volume Of Cooling Air:
295.0 m3/h
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
Discrete Output Type:
programmable output DQ1, DQ2 30 V DC 100 mA
Maximum Deflection Under Vibratory Load (During Operation):
1.5 mm at 2...13 Hz
Assembly Style:
with heat sink
Net Weight:
56.4 kg
Communication Port Protocol:
Modbus TCP || Modbus serial || EtherNet/IP
Pollution Degree:
2 IEC 61800-5-1
Product Specific Application:
machine
With Sft Fct Safe Stop 2 (Ss2):
FALSE
Transmission Rate:
4.8 kbit/s || 9.6 kbit/s || 19.2 kbit/s || 38.4 kbit/s
Number Of Addresses:
1-247
With Safety Function Safely Limited Position (Slp):
FALSE
Phase:
3 phase
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Transmission Frame:
RTU
Maximum Transient Current:
127.2 A 60 s normal duty) || 132 A 60 s heavy duty) || 127.2 A 2 s normal duty) || 132 A 2 s heavy duty)
Continuous Output Current:
106 A 4 kHz normal duty || 88 A 4 kHz heavy duty
Brake Chopper Integrated:
TRUE
Line Current:
97.2 A 380 V normal duty) || 84.2 A 480 V normal duty) || 81.4 A 380 V heavy duty) || 71.8 A 480 V heavy duty)
Data Format:
8 bits, configurable odd, even or no parity
Height:
908.0 mm
Electrical Connection:
screw terminal 0.75...1.5 mm² control || screw terminal 70...120 mm² line side || screw terminal 70...120 mm² DC bus || screw terminal 70...120 mm² motor
Type Of Polarization:
no impedance
With Safety Function Safe Programmable Logic:
FALSE
Nominal Output Current:
88.0 A
Discrete Input Logic:
16 preset speeds
Range Of Product:
Altivar Machine ATV340
Synchronous Motor Control Profile:
reluctance motor || permanent magnet motor
Base Load Current At High Overload:
88.0 A
Output Voltage:
<= power supply voltage
Physical Interface:
2-wire RS 485
Discrete Input Type:
PTI safe torque off 0-30 kHz, 24 V DC 30 V) || DI1...DI5 programmable as pulse input, 24 V DC 30 V)3.5 kOhm || programmable
With Safety Function Safe Operating Stop (Sos):
FALSE
Electrical Connection:
control screw terminal 0.75...1.5 mm² AWG 18...AWG 16 || line side screw terminal 70...120 mm² AWG 1/0...250 kcmil || DC bus screw terminal 70...120 mm² AWG 1/0...250 kcmil || motor screw terminal 70...120 mm² AWG 1/0...250 kcmil
Relay Output Type:
relay outputs R1A || relay outputs R1C 100000 cycles || relay outputs R2A || relay outputs R2C 100000 cycles
Power Dissipation In W:
natural convection 105 W 380 V 4 kHz heavy duty) || forced convection 943 W 380 V 4 kHz heavy duty) || natural convection 115 W 380 V 4 kHz normal duty) || forced convection 917 W 380 V 4 kHz normal duty)
Standards:
IEC 61800-3 || IEC 61800-5-1 || IEC 60721-3 || IEC 61508 || IEC 13849-1 || UL 618000-5-1 || UL 508C || IEC 61000-3-12
Motor Slip Compensation:
not available in permanent magnet motor law || can be suppressed || adjustable || automatic whatever the load
Discrete Output Number:
1
[Us] Rated Supply Voltage:
380...480 V - 15...10 %
Regulation Loop:
adjustable PID regulator
Product Or Component Type:
variable speed drive
Analogue Input Number:
3
Ip Degree Of Protection:
IP20
Maximum Output Voltage:
480 V
Maximum Acceleration Under Vibrational Stress (During Operation):
10 m/s² at 13...200 Hz
Protection Type:
thermal protection motor || safe torque off motor || motor phase loss motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent drive || output overcurrent between motor phase and earth drive || output overcurrent
Ambient Air Transport Temperature:
-40-70 °C
Overvoltage Category:
class III
Line Current:
97.2 A 380 V with internal line choke normal duty) || 84.2 A 480 V with internal line choke normal duty) || 81.4 A 380 V with internal line choke heavy duty) || 71.8 A 480 V with internal line choke heavy duty) || 81.4 A || 71.8 A
Environmental Disclosure:
ENVPEP1411014EN
Analogue Output Number:
2
Minimum Switching Current:
relay output R1B 5 mA 24 V DC || relay output R2C 5 mA 24 V DC
With Safety Function Safe Direction (Sdi):
FALSE
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Method Of Access:
slave Modbus RTU || slave Modbus TCP
Type Of Cooling:
forced convection
Maximum Thdi:
<48 % full load IEC 61000-3-12 || <48 % 80 % load IEC 61000-3-12
Switching Frequency:
1...8 kHz adjustable || 2.5...8 kHz with derating factor
4 Quadrant Operation Possible:
TRUE
Isolation:
between power and control terminals
Marking:
CE
Permitted Relative Humidity (During Operation):
class 3K5 according to EN 60721-3
With Safety Function Safely Limited Speed (Sls):
TRUE
Operating Altitude:
<= 4800 m with current derating above 1000m
Pollution Degree:
2
Connector Type:
3 RJ45
Variant:
standard version
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Circularity Profile:
ENVEOLI1411014EN
Upgradeability:
Upgraded components available
With Safety Function Safe Position (Sp):
FALSE
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
China Rohs Regulation:
X
Acceleration And Deceleration Ramps:
S, U or customized || linear adjustable separately from 0.01...9999 s
Analogue Input Type:
AI1 software-configurable current 0...20 mA 250 Ohm 12 bits || AI1 software-configurable temperature probe or water level sensor || AI1 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI2 software-configurable voltage - 10...10 V DC 31
Prospective Line Isc:
50 kA
Asynchronous Motor Control Profile:
constant torque standard || optimized torque mode || variable torque standard
Supply Frequency:
50...60 Hz +/- 5 %
Maximum Switching Current:
relay output R1C resistive, cos phi = 1 3 A 250 V AC || relay output R1C resistive, cos phi = 1 3 A 30 V DC || relay output R1C inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1C inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Emc Filter:
class C3 EMC filter integrated
Width:
271.0 mm
Ambient Air Temperature For Storage:
-40-70 °C
Degree Of Protection:
UL type 1
Operating Position:
vertical +/- 10 degree
Braking To Standstill:
by DC injection
Noise Level:
62.4 dB
Relay Output Number:
3
Motor Power Kw:
55 kW normal duty || 45 kW heavy duty
Base Load Current At Low Overload:
106.0 A
Maximum Acceleration Under Shock Impact (During Operation):
150 m/s² at 11 ms
Sustainable Offer Status:
Green Premium product
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric ATV340D45N4E Atv340 45Kw 60Hp 400V With Ethernet Vari
  • Schneider Electric ATV340D45N4E Atv340 45Kw 60Hp 400V With Ethernet Vari
$8,969.63

Description

This Altivar 340 variable speed drive can feed 3-phase synchronous and asynchronous motors in open and closed loop control. Altivar Machine ATV340 drives are sized heavy duty as standard. It works at a rated power up to 45kW / 60hp and a rated voltage from 380V to 480V AC. ATV340 has been designed to meet the needs of applications for harsh environments, such as vibration, shock and non-conductive dust and where high temperature resistance up to 60 °C is needed. This product integrates Modbus serial line communication protocols as standard. This drive features multi-protocol Ethernet embedded, it consists of Ethernet IP and Modbus TCP communication interfaces. it weighs 56.4kg and its dimensions are, 271mm wide, 908mm high, 309mm deep. ATV340 incorporates functions and features suitable for the most common applications, including packaging, material handling, material working, hoisting. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions), IEC 60721-3, IEC 61508, IEC 13849-1. It is also CE, UL, CSA, and TÜV certified. Accessories and options (encoder interface modules, I/O expansion modules, communication modules, braking resistors, line chokes, additional EMC filters) are available with Altivar Machine ATV340 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. It is fully integrated inside Schneider Electric’s EcoStruxure Machine through DTM. It is possible to configure, control, and diagnose ATV340 drives directly in SoMachine and SoMove software by means of the same software brick (DTM). It is eco-friendly and complies with directives such as RoHS relating to environmental protection.
View AllClose