Switching Frequency:
2...8 kHz adjustable || 4...8 kHz with derating factor
Type Of Cooling:
forced convection
Volume Of Cooling Air:
330 m3/h
Safety Function:
STO (safe torque off) SIL 3
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Acceleration And Deceleration Ramps:
S, U or customized || linear adjustable separately from 0.01...9999 s
Frequency Resolution:
display unit 0.1 Hz || analog input 0.012/50 Hz
Pollution Degree:
2
Discrete Output Type:
relay outputs R1A, R1B, R1C 250 V AC 3000 mA || relay outputs R1A, R1B, R1C 30 V DC 3000 mA || relay outputs R2A, R2C 250 V AC 5000 mA || relay outputs R2A, R2C 30 V DC 5000 mA || relay outputs R3A, R3C 250 V AC 5000 mA || relay outputs R3A, R3C 30 V
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
Number Of Addresses:
1-247 Modbus serial
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Quantity Per Set:
1
Supply Frequency:
50...60 Hz - 5...5 %
Discrete Input Logic:
16 preset speeds
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Range Of Product:
Altivar Process ATV600
Variant:
standard version
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI4) - discrete input || 5 ms +/- 1 ms DI5, DI6) - discrete input || 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input || 10 ms +/- 1 ms AO1) - analog output
Input Compatibility:
DI1...DI6 discrete input level 1 PLC IEC 61131-2 || DI5, DI6 discrete input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
Product Destination:
asynchronous motors || synchronous motors
Continuous Output Current:
29 A 4 kHz normal duty || 24 A 4 kHz heavy duty
Product Specific Application:
process and utilities
Transmission Frame:
RTU
[Us] Rated Supply Voltage:
500...690 V
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Option Card:
slot A communication module, Profibus DP V1 || slot A communication module, PROFINET || slot A communication module, DeviceNet || slot A communication module, Modbus TCP/EtherNet/IP || slot A communication module, CANopen daisy chain RJ45 || slot A c
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Depth:
242 mm
Standards:
UL 508C || IEC 61800-3 || EN/IEC 61800-3 environment 2 category C3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Device Short Name:
ATV630
Speed Drive Output Frequency:
0.1-500 Hz
Rohs Exemption Information:
Yes
Analogue Output Number:
2
Mercury Free:
Yes
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Enclosure Mounting:
wall mounted
Connector Type:
RJ45 on the remote graphic terminal)Ethernet/Modbus TCP || RJ45 on the remote graphic terminal)Modbus serial
Prospective Line Isc:
70 kA
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Permissible Temporary Current Boost:
1.1 x In 60 s normal duty) || 1.5 x In 60 s heavy duty)
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Noise Level:
58 dB
Marking:
CE
[Us] Rated Supply Voltage:
500...690 V - 15...10 %
Electrical Connection:
control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 || motor screw terminal 10 mm² AWG 8 || line side screw terminal 10 mm² AWG 8
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits || AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
Pollution Degree:
2 IEC 61800-5-1
Phase:
3 phase
Product Or Component Type:
variable speed drive
Maximum Thdi:
<48 % with external line choke IEC 61000-3-12
Regulation Loop:
adjustable PID regulator
Noise Level:
52 dB 86/188/EEC
Apparent Power:
31.1 kVA 690 V normal duty) || 27.5 kVA 690 V heavy duty)
Upgradeability:
Upgraded components available
Communication Port Protocol:
Modbus TCP || Ethernet || Modbus serial
Braking To Standstill:
by DC injection
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Data Format:
8 bits, configurable odd, even or no parity
Discrete Input Number:
8
Output Voltage:
<= power supply voltage
Discrete Output Number:
0
China Rohs Regulation:
X
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge immu
Isolation:
between power and control terminals
Analogue Input Number:
3
Method Of Access:
slave Modbus TCP
Local Signalling:
for local diagnostic 3 LEDs || for embedded communication status 3 LEDs (dual colour) || for communication module status 4 LEDs (dual colour) || for presence of voltage 1 LED (red)
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 100000 cycles || configurable relay logic R3 sequence relay NO 100000 cycles
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Maximum Transient Current:
31.9 A 60 s normal duty) || 36 A 60 s heavy duty)
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Environmental Disclosure:
ENVPEP1704001EN
Maximum Switching Current:
relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC || relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2
Discrete Input Type:
DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
Power Dissipation In W:
natural convection 138 W 500 V 4 kHz || forced convection 463 W 500 V 4 kHz
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Width:
246 mm
Maximum Output Frequency:
500 kHz
Motor Power Kw:
18.5 kW 500 V normal duty) || 15 kW 500 V heavy duty) || 22 kW 690 V normal duty) || 18.5 kW 690 V heavy duty)
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Motor Slip Compensation:
not available in permanent magnet motor law || automatic whatever the load || can be suppressed || adjustable
Asynchronous Motor Control Profile:
constant torque standard || optimized torque mode || variable torque standard
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V
Type Of Polarization:
no impedance
Sustainable Offer Status:
Green Premium product
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AO1, AO2 +/- 0.2 % analog output
Nominal Switching Frequency:
4 kHz
Net Weight:
22 kg
Emc Filter:
integrated 25 m IEC 61800-3 category C3
Height:
420 mm
Overvoltage Category:
III
Ip Degree Of Protection:
IP00IEC 61800-5-1 || IP00IEC 60529 || IP20 with kit VW3A9705)IEC 61800-5-1 || IP20 with kit VW3A9705)IEC 60529
Product Certifications:
UL || CSA || TÜV
Transmission Rate:
10, 100 Mbits || 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Line Current:
27.6 A 500 V normal duty) || 26 A 690 V normal duty) || 23.2 A 500 V heavy duty) || 23 A 690 V heavy duty)
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Maximum Horse Power Rating:
25 hp 500 V normal duty || 20 hp 500 V heavy duty || 30 hp 690 V normal duty || 25 hp 690 V heavy duty
Relay Output Number:
3
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 10 bits || software-configurable current DQ-, DQ+ 30 V DC || software-configurable current DQ-, DQ+ 100 mA
Ambient Air Temperature For Storage:
-40-70 °C
Mounting Mode:
wall mount
Circularity Profile:
ENVEOLI1704001EN
Operating Position:
vertical +/- 10 degree
Physical Interface:
Ethernet || 2-wire RS 485
  • Schneider Electric ATV630D22Y6 Atv630Ip00 22Kw 500V-690V Variable Spee
  • Schneider Electric ATV630D22Y6 Atv630Ip00 22Kw 500V-690V Variable Spee
$6,418.80

Description

This Altivar Process ATV600 variable speed drive can feed 3-phase synchronous and asynchronous power motors. This variable speed drive features an integrated EMC filter with 25m cable conforming to category C3. It works at a rated supply voltage from 500V to 690VAC. This drive provides up to 30% energy saving when on standby due to the innovative ‘‘Stop and Go’’operation without additional costs. It is suitable for motors with power rating up to 22kW/30hp for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 18.5kW/25HP for applications requiring significant overload (up to 150%). Its dimensions are 246mm (width) x 242mm (depth) x 420mm (height). It weighs 22kg. This drive is focused on fluids management processing and energy saving, it offers extensive flexibility in water and wastewater, mining, minerals and metals, oil and gas and food and beverage applications. This product is certified by CE, CSA and TUV. It meets UL 508C, EN/IEC 61800-3, EN/IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508 and IEC 13849-1 standards. Accessories (fan kit, graphic display terminal) and options (line chokes, dv/dt filter, sinus filter, EMC filter) are available with Altivar Process ATV600 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a wall. This new concept of drives meets the major needs of process and utilities in terms of equipment efficiency and total cost of ownership by supporting the energy management, asset management and also the overall performance of the process.
View AllClose