null

Schneider Electric ATV630D37N4 Variable Speed Drive Ip21 37Kw 400V/480V

Schneider Electric
SKU:
ATV630D37N4
|
UPC:
3606480701429
$8,020.95
(No reviews yet) Write a Review
Condition:
New
Current Stock:
This Altivar Process ATV600 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It features 3 built-in RJ45 communication ports as standard, 1 Ethernet port, 2 serial ports. It works at a rated supply voltage from 380V to 480V AC. This drive provides up to 30% energy saving when on standby due to the innovative ‘‘Stop and Go’’operation without additional costs. It is suitable for motors with power rating up to 37kW / 50hp for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 30kW / 40hp for applications requiring significant overload (up to 150%). It weighs 28.2kg and its dimensions are, 226mm wide, 673mm high, 271mm deep. This drive is focused on fluids management processing and energy saving, it offers extensive flexibility in water and wastewater, mining, minerals and metals, oil and gas and food and beverage applications. Accessories (fan kit, graphic display terminal) and options (I/O expansion modules, communication modules, EMC input filters) are available with Altivar Process ATV600 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a wall. This new concept of drives meets the major needs of process and utilities in terms of equipment efficiency and total cost of ownership by supporting the energy management, asset management and also the overall performance of the process.
[Us] Rated Supply Voltage:
380...480 V - 15...10 %
Degree Of Protection:
UL type 1 UL 508C
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Physical Interface:
Ethernet || 2-wire RS 485
Connector Type:
RJ45 on the remote graphic terminal)Ethernet/Modbus TCP || RJ45 on the remote graphic terminal)Modbus serial
Maximum Output Frequency:
500 kHz
Discrete And Process Manufacturing:
building - HVAC compressor centrifugal || food and beverage processing other application || mining mineral and metal fan || mining mineral and metal pump || oil and gas fan || water and waste water other application || building - HVAC screw compresso
Discrete Input Number:
8
Environmental Disclosure:
ENVPEP1411001EN
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Volume Of Cooling Air:
240 m3/h
Number Of Addresses:
1-247 Modbus serial
Nominal Switching Frequency:
4 kHz
Quantity Per Set:
1
Marking:
CE
Analogue Output Number:
2
Power Range:
30-50 kW 380-440 V 3 phase || 30-50 kW 480-500 V 3 phase
Transmission Frame:
RTU
Net Weight:
28.2 kg
Depth:
271 mm
Switching Frequency:
2...12 kHz adjustable || 4...12 kHz with derating factor
Product Or Component Type:
variable speed drive
Device Short Name:
ATV630
Circularity Profile:
ENVEOLI1411001EN
Maximum Switching Current:
relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC || relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2
Ambient Air Temperature For Storage:
-40-70 °C
Discrete Input Logic:
16 preset speeds
Relay Output Number:
3
Upgradeability:
Upgraded components available
Rohs Exemption Information:
Yes
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Communication Port Protocol:
Ethernet || Modbus TCP || Modbus serial
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Maximum Transient Current:
82 A 60 s normal duty) || 92.3 A 60 s heavy duty)
Mercury Free:
Yes
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V
Enclosure Mounting:
wall mounted
Maximum Thdi:
<48 % from 80...100 % of load IEC 61000-3-12
Sustainable Offer Status:
Green Premium product
Product Certifications:
DNV-GL || TÜV || ATEX INERIS || CSA || UL || ATEX zone 2/22
Mounting Mode:
wall mount
Option Card:
slot A communication module, Profibus DP V1 || slot A communication module, PROFINET || slot A communication module, DeviceNet || slot A communication module, Modbus TCP/EtherNet/IP || slot A communication module, CANopen daisy chain RJ45 || slot A c
Discrete Output Number:
0
Permissible Temporary Current Boost:
1.1 x In 60 s normal duty) || 1.5 x In 60 s heavy duty)
Phase:
3 phase
Emc Filter:
integrated 50 m EN/IEC 61800-3 category C2 || integrated 150 m EN/IEC 61800-3 category C3
Width:
226 mm
Method Of Access:
slave Modbus TCP
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Operating Position:
vertical +/- 10 degree
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AO1, AO2 +/- 0.2 % analog output
Type Of Cooling:
forced convection
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
China Rohs Regulation:
X
Analogue Input Number:
3
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 100000 cycles || configurable relay logic R3 sequence relay NO 100000 cycles
Noise Level:
63.5 dB
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Ip Degree Of Protection:
IP21IEC 61800-5-1 || IP21IEC 60529
Asynchronous Motor Control Profile:
variable torque standard || constant torque standard || optimized torque mode
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
Pollution Degree:
2
Power Dissipation In W:
natural convection 106 W 380 V 4 kHz || forced convection 796 W 380 V 4 kHz
Electrical Connection:
control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 || line side screw terminal 35...50 mm² AWG 3...AWG 1 || motor screw terminal 35...50 mm² AWG 3...AWG 1
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Motor Power Kw:
37 kW normal duty) || 30 kW heavy duty)
Data Format:
8 bits, configurable odd, even or no parity
Type Of Polarization:
no impedance
Speed Drive Output Frequency:
0.1-500 Hz
Transmission Rate:
10, 100 Mbits || 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Continuous Output Current:
74.5 A 4 kHz normal duty || 61.5 A 4 kHz heavy duty
Safety Function:
STO (safe torque off) SIL 3
Output Voltage:
<= power supply voltage
Noise Level:
63.5 dB 86/188/EEC
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Product Destination:
asynchronous motors || synchronous motors
Regulation Loop:
adjustable PID regulator
Standards:
UL 508C || EN/IEC 61800-3 || EN/IEC 61800-3 environment 1 category C2 || EN/IEC 61800-3 environment 2 category C3 || EN/IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits || AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
Motor Slip Compensation:
not available in permanent magnet motor law || can be suppressed || adjustable || automatic whatever the load
Pollution Degree:
2 EN/IEC 61800-5-1
Prospective Line Isc:
50 kA
Discrete Input Type:
DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
[Us] Rated Supply Voltage:
380...480 V
Maximum Horse Power Rating:
50 hp normal duty || 40 hp heavy duty
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Height:
673 mm
Frequency Resolution:
display unit 0.1 Hz || analog input 0.012/50 Hz
Variant:
standard version
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Overvoltage Category:
III
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Apparent Power:
47.6 kVA 480 V normal duty) || 40.2 kVA 480 V heavy duty)
Discrete Output Type:
relay outputs R1A, R1B, R1C 250 V AC 3000 mA || relay outputs R1A, R1B, R1C 30 V DC 3000 mA || relay outputs R2A, R2C 250 V AC 5000 mA || relay outputs R2A, R2C 30 V DC 5000 mA || relay outputs R3A, R3C 250 V AC 5000 mA || relay outputs R3A, R3C 30 V
Range Of Product:
Altivar Process ATV600
Line Current:
66.2 A 380 V normal duty) || 57.3 A 480 V normal duty) || 54.8 A 380 V heavy duty) || 48.3 A 480 V heavy duty)
Supply Frequency:
50...60 Hz - 5...5 %
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Product Specific Application:
process and utilities
Braking To Standstill:
by DC injection
Isolation:
between power and control terminals
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI4) - discrete input || 5 ms +/- 1 ms DI5, DI6) - discrete input || 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input || 10 ms +/- 1 ms AO1) - analog output
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 10 bits || software-configurable current DQ-, DQ+ 30 V DC || software-configurable current DQ-, DQ+ 100 mA
Input Compatibility:
DI1...DI6 discrete input level 1 PLC EN/IEC 61131-2 || DI5, DI6 discrete input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC EN/IEC 61131-2
Local Signalling:
for local diagnostic 3 LEDs || for embedded communication status 3 LEDs (dual colour) || for communication module status 4 LEDs (dual colour) || for presence of voltage 1 LED (red)
Brochure:
View
Catalog:
View
Datasheet:
View