Schneider Electric ATV630D37N4 Variable Speed Drive Ip21 37Kw 400V/480V
Schneider Electric
$8,020.95
This Altivar Process ATV600 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It features 3 built-in RJ45 communication ports as standard, 1 Ethernet port, 2 serial ports. It works at a rated supply voltage from 380V to 480V AC. This drive provides up to 30% energy saving when on standby due to the innovative ‘‘Stop and Go’’operation without additional costs. It is suitable for motors with power rating up to 37kW / 50hp for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 30kW / 40hp for applications requiring significant overload (up to 150%). It weighs 28.2kg and its dimensions are, 226mm wide, 673mm high, 271mm deep. This drive is focused on fluids management processing and energy saving, it offers extensive flexibility in water and wastewater, mining, minerals and metals, oil and gas and food and beverage applications. Accessories (fan kit, graphic display terminal) and options (I/O expansion modules, communication modules, EMC input filters) are available with Altivar Process ATV600 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a wall. This new concept of drives meets the major needs of process and utilities in terms of equipment efficiency and total cost of ownership by supporting the energy management, asset management and also the overall performance of the process.
- [Us] Rated Supply Voltage:
- 380...480 V - 15...10 %
- Degree Of Protection:
- UL type 1 UL 508C
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Physical Interface:
- Ethernet || 2-wire RS 485
- Connector Type:
- RJ45 on the remote graphic terminal)Ethernet/Modbus TCP || RJ45 on the remote graphic terminal)Modbus serial
- Maximum Output Frequency:
- 500 kHz
- Discrete And Process Manufacturing:
- building - HVAC compressor centrifugal || food and beverage processing other application || mining mineral and metal fan || mining mineral and metal pump || oil and gas fan || water and waste water other application || building - HVAC screw compresso
- Discrete Input Number:
- 8
- Environmental Disclosure:
- ENVPEP1411001EN
- Electromagnetic Compatibility:
- electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
- Volume Of Cooling Air:
- 240 m3/h
- Number Of Addresses:
- 1-247 Modbus serial
- Nominal Switching Frequency:
- 4 kHz
- Quantity Per Set:
- 1
- Marking:
- CE
- Analogue Output Number:
- 2
- Power Range:
- 30-50 kW 380-440 V 3 phase || 30-50 kW 480-500 V 3 phase
- Transmission Frame:
- RTU
- Net Weight:
- 28.2 kg
- Depth:
- 271 mm
- Switching Frequency:
- 2...12 kHz adjustable || 4...12 kHz with derating factor
- Product Or Component Type:
- variable speed drive
- Device Short Name:
- ATV630
- Circularity Profile:
- ENVEOLI1411001EN
- Maximum Switching Current:
- relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC || relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2
- Ambient Air Temperature For Storage:
- -40-70 °C
- Discrete Input Logic:
- 16 preset speeds
- Relay Output Number:
- 3
- Upgradeability:
- Upgraded components available
- Rohs Exemption Information:
- Yes
- Accuracy:
- +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
- Communication Port Protocol:
- Ethernet || Modbus TCP || Modbus serial
- Vibration Resistance:
- 1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
- Maximum Transient Current:
- 82 A 60 s normal duty) || 92.3 A 60 s heavy duty)
- Mercury Free:
- Yes
- Discrete Input Logic:
- positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V
- Enclosure Mounting:
- wall mounted
- Maximum Thdi:
- <48 % from 80...100 % of load IEC 61000-3-12
- Sustainable Offer Status:
- Green Premium product
- Product Certifications:
- DNV-GL || TÃV || ATEX INERIS || CSA || UL || ATEX zone 2/22
- Mounting Mode:
- wall mount
- Option Card:
- slot A communication module, Profibus DP V1 || slot A communication module, PROFINET || slot A communication module, DeviceNet || slot A communication module, Modbus TCP/EtherNet/IP || slot A communication module, CANopen daisy chain RJ45 || slot A c
- Discrete Output Number:
- 0
- Permissible Temporary Current Boost:
- 1.1 x In 60 s normal duty) || 1.5 x In 60 s heavy duty)
- Phase:
- 3 phase
- Emc Filter:
- integrated 50 m EN/IEC 61800-3 category C2 || integrated 150 m EN/IEC 61800-3 category C3
- Width:
- 226 mm
- Method Of Access:
- slave Modbus TCP
- Synchronous Motor Control Profile:
- permanent magnet motor || synchronous reluctance motor
- Operating Position:
- vertical +/- 10 degree
- Linearity Error:
- AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AO1, AO2 +/- 0.2 % analog output
- Type Of Cooling:
- forced convection
- Exchange Mode:
- half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
- China Rohs Regulation:
- X
- Analogue Input Number:
- 3
- Relay Output Type:
- configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 100000 cycles || configurable relay logic R3 sequence relay NO 100000 cycles
- Noise Level:
- 63.5 dB
- Insulation Resistance:
- > 1 MOhm 500 V DC for 1 minute to earth
- Ip Degree Of Protection:
- IP21IEC 61800-5-1 || IP21IEC 60529
- Asynchronous Motor Control Profile:
- variable torque standard || constant torque standard || optimized torque mode
- Ambient Air Temperature For Operation:
- -15-50 °C without derating) || 50-60 °C with derating factor)
- Pollution Degree:
- 2
- Power Dissipation In W:
- natural convection 106 W 380 V 4 kHz || forced convection 796 W 380 V 4 kHz
- Electrical Connection:
- control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 || line side screw terminal 35...50 mm² AWG 3...AWG 1 || motor screw terminal 35...50 mm² AWG 3...AWG 1
- Relative Humidity:
- 5-95 % without condensation IEC 60068-2-3
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Motor Power Kw:
- 37 kW normal duty) || 30 kW heavy duty)
- Data Format:
- 8 bits, configurable odd, even or no parity
- Type Of Polarization:
- no impedance
- Speed Drive Output Frequency:
- 0.1-500 Hz
- Transmission Rate:
- 10, 100 Mbits || 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
- Continuous Output Current:
- 74.5 A 4 kHz normal duty || 61.5 A 4 kHz heavy duty
- Safety Function:
- STO (safe torque off) SIL 3
- Output Voltage:
- <= power supply voltage
- Noise Level:
- 63.5 dB 86/188/EEC
- Shock Resistance:
- 15 gn 11 ms IEC 60068-2-27
- Product Destination:
- asynchronous motors || synchronous motors
- Regulation Loop:
- adjustable PID regulator
- Standards:
- UL 508C || EN/IEC 61800-3 || EN/IEC 61800-3 environment 1 category C2 || EN/IEC 61800-3 environment 2 category C3 || EN/IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
- Acceleration And Deceleration Ramps:
- linear adjustable separately from 0.01...9999 s
- Protection Type:
- thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
- Analogue Input Type:
- AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits || AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
- Motor Slip Compensation:
- not available in permanent magnet motor law || can be suppressed || adjustable || automatic whatever the load
- Pollution Degree:
- 2 EN/IEC 61800-5-1
- Prospective Line Isc:
- 50 kA
- Discrete Input Type:
- DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
- [Us] Rated Supply Voltage:
- 380...480 V
- Maximum Horse Power Rating:
- 50 hp normal duty || 40 hp heavy duty
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Height:
- 673 mm
- Frequency Resolution:
- display unit 0.1 Hz || analog input 0.012/50 Hz
- Variant:
- standard version
- Minimum Switching Current:
- relay output R1, R2, R3 5 mA 24 V DC
- Overvoltage Category:
- III
- Operating Altitude:
- <= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
- Apparent Power:
- 47.6 kVA 480 V normal duty) || 40.2 kVA 480 V heavy duty)
- Discrete Output Type:
- relay outputs R1A, R1B, R1C 250 V AC 3000 mA || relay outputs R1A, R1B, R1C 30 V DC 3000 mA || relay outputs R2A, R2C 250 V AC 5000 mA || relay outputs R2A, R2C 30 V DC 5000 mA || relay outputs R3A, R3C 250 V AC 5000 mA || relay outputs R3A, R3C 30 V
- Range Of Product:
- Altivar Process ATV600
- Line Current:
- 66.2 A 380 V normal duty) || 57.3 A 480 V normal duty) || 54.8 A 380 V heavy duty) || 48.3 A 480 V heavy duty)
- Supply Frequency:
- 50...60 Hz - 5...5 %
- Supply:
- external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
- Product Specific Application:
- process and utilities
- Braking To Standstill:
- by DC injection
- Isolation:
- between power and control terminals
- Refresh Time:
- relay output R1, R2, R3)5 ms +/- 0.5 ms)
- Sampling Duration:
- 2 ms +/- 0.5 ms DI1...DI4) - discrete input || 5 ms +/- 1 ms DI5, DI6) - discrete input || 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input || 10 ms +/- 1 ms AO1) - analog output
- Analogue Output Type:
- software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 10 bits || software-configurable current DQ-, DQ+ 30 V DC || software-configurable current DQ-, DQ+ 100 mA
- Input Compatibility:
- DI1...DI6 discrete input level 1 PLC EN/IEC 61131-2 || DI5, DI6 discrete input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC EN/IEC 61131-2
- Local Signalling:
- for local diagnostic 3 LEDs || for embedded communication status 3 LEDs (dual colour) || for communication module status 4 LEDs (dual colour) || for presence of voltage 1 LED (red)
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View