Schneider Electric ATV630U22Y6 Atv630Ip00 2,2Kw 500V-690V Variable Spe

(No reviews yet) Write a Review
SKU:
ATV630U22Y6
UPC:
3606481325099
Condition:
New
Motor Power Kw:
1.5 kW 500 V normal duty) || 1.1 kW 500 V heavy duty) || 2.2 kW 690 V normal duty) || 1.5 kW 690 V heavy duty)
Analogue Output Number:
2
Rohs Exemption Information:
Yes
Motor Slip Compensation:
adjustable || automatic whatever the load || not available in permanent magnet motor law || can be suppressed
Maximum Switching Current:
relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC || relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2
Prospective Line Isc:
70 kA
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Upgradeability:
Upgraded components available
Physical Interface:
Ethernet || 2-wire RS 485
Discrete Output Type:
relay outputs R1A, R1B, R1C 250 V AC 3000 mA || relay outputs R1A, R1B, R1C 30 V DC 3000 mA || relay outputs R2A, R2C 250 V AC 5000 mA || relay outputs R2A, R2C 30 V DC 5000 mA || relay outputs R3A, R3C 250 V AC 5000 mA || relay outputs R3A, R3C 30 V
Maximum Horse Power Rating:
2 hp 500 V normal duty || 1.5 hp 500 V heavy duty || 3 hp 690 V normal duty || 2 hp 690 V heavy duty
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Emc Filter:
integrated 25 m IEC 61800-3 category C3
Connector Type:
RJ45 on the remote graphic terminal)Ethernet/Modbus TCP || RJ45 on the remote graphic terminal)Modbus serial
Environmental Disclosure:
ENVPEP1704001EN
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AO1, AO2 +/- 0.2 % analog output
Height:
420 mm
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Apparent Power:
4.3 kVA 690 V normal duty) || 3.1 kVA 690 V heavy duty)
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Input Compatibility:
DI1...DI6 discrete input level 1 PLC IEC 61131-2 || DI5, DI6 discrete input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Data Format:
8 bits, configurable odd, even or no parity
Output Voltage:
<= power supply voltage
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge immu
Line Current:
3.4 A 500 V normal duty) || 3.6 A 690 V normal duty) || 2.6 A 500 V heavy duty) || 2.6 A 690 V heavy duty)
Variant:
standard version
Noise Level:
58 dB
Operating Position:
vertical +/- 10 degree
Maximum Transient Current:
3.4 A 60 s normal duty) || 3.6 A 60 s heavy duty)
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Net Weight:
22 kg
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
Maximum Output Frequency:
500 kHz
Pollution Degree:
2 IEC 61800-5-1
Pollution Degree:
2
Sustainable Offer Status:
Green Premium product
Volume Of Cooling Air:
330 m3/h
Discrete Input Logic:
16 preset speeds
Circularity Profile:
ENVEOLI1704001EN
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 100000 cycles || configurable relay logic R3 sequence relay NO 100000 cycles
Permissible Temporary Current Boost:
1.1 x In 60 s normal duty) || 1.5 x In 60 s heavy duty)
Frequency Resolution:
display unit 0.1 Hz || analog input 0.012/50 Hz
Speed Drive Output Frequency:
0.1-500 Hz
Asynchronous Motor Control Profile:
optimized torque mode || variable torque standard || constant torque standard
Width:
246 mm
Discrete Input Type:
DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
Mercury Free:
Yes
Braking To Standstill:
by DC injection
Discrete Input Number:
8
Isolation:
between power and control terminals
Phase:
3 phase
China Rohs Regulation:
X
Overvoltage Category:
III
[Us] Rated Supply Voltage:
500...690 V - 15...10 %
Transmission Rate:
10, 100 Mbits || 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Ambient Air Temperature For Storage:
-40-70 °C
Number Of Addresses:
1-247 Modbus serial
Maximum Thdi:
<48 % with external line choke IEC 61000-3-12
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Power Dissipation In W:
natural convection 73 W 500 V 4 kHz || forced convection 43 W 500 V 4 kHz
Product Certifications:
CSA || TÜV || UL
Marking:
CE
Safety Function:
STO (safe torque off) SIL 3
Depth:
242 mm
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI4) - discrete input || 5 ms +/- 1 ms DI5, DI6) - discrete input || 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input || 10 ms +/- 1 ms AO1) - analog output
Mounting Mode:
wall mount
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits || AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
Device Short Name:
ATV630
[Us] Rated Supply Voltage:
500...690 V
Discrete Output Number:
0
Product Specific Application:
process and utilities
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Method Of Access:
slave Modbus TCP
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Local Signalling:
for local diagnostic 3 LEDs || for embedded communication status 3 LEDs (dual colour) || for communication module status 4 LEDs (dual colour) || for presence of voltage 1 LED (red)
Product Destination:
asynchronous motors || synchronous motors
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Noise Level:
52 dB 86/188/EEC
Product Or Component Type:
variable speed drive
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Switching Frequency:
2...8 kHz adjustable || 4...8 kHz with derating factor
Standards:
UL 508C || IEC 61800-3 || EN/IEC 61800-3 environment 2 category C3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Enclosure Mounting:
wall mounted
Transmission Frame:
RTU
Supply Frequency:
50...60 Hz - 5...5 %
Type Of Cooling:
forced convection
Ip Degree Of Protection:
IP00IEC 61800-5-1 || IP00IEC 60529 || IP20 with kit VW3A9705)IEC 61800-5-1 || IP20 with kit VW3A9705)IEC 60529
Nominal Switching Frequency:
4 kHz
Electrical Connection:
control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 || motor screw terminal 4...10 mm² AWG 12...AWG 8 || line side screw terminal 4...10 mm² AWG 12...AWG 8
Analogue Input Number:
3
Communication Port Protocol:
Ethernet || Modbus serial || Modbus TCP
Option Card:
slot A communication module, Profibus DP V1 || slot A communication module, PROFINET || slot A communication module, DeviceNet || slot A communication module, Modbus TCP/EtherNet/IP || slot A communication module, CANopen daisy chain RJ45 || slot A c
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Quantity Per Set:
1
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Acceleration And Deceleration Ramps:
S, U or customized || linear adjustable separately from 0.01...9999 s
Continuous Output Current:
3.1 A 4 kHz normal duty || 2.4 A 4 kHz heavy duty
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 10 bits || software-configurable current DQ-, DQ+ 30 V DC || software-configurable current DQ-, DQ+ 100 mA
Relay Output Number:
3
Type Of Polarization:
no impedance
Range Of Product:
Altivar Process ATV600
Regulation Loop:
adjustable PID regulator
$3,561.14

Description

This Altivar Process ATV600 variable speed drive can feed 3-phase synchronous and asynchronous power motors. This variable speed drive features an integrated EMC filter with 25m cable conforming to category C3. It works at a rated supply voltage from 500V to 690VAC. This drive provides up to 30% energy saving when on standby due to the innovative ‘‘Stop and Go’’operation without additional costs. It is suitable for motors with power rating up to 2.2kW/3HP (500V supply voltage) for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 1.5kW/2HP (500V supply voltage) for applications requiring significant overload (up to 150%). Its dimensions are 246mm (width) x 242mm (depth) x 420mm (height). It weighs 22kg. This drive is focused on fluids management processing and energy saving, it offers extensive flexibility in water and wastewater, mining, minerals and metals, oil and gas and food and beverage applications. This product is certified by CE, CSA and TUV. It meets UL 508C, EN/IEC 61800-3, EN/IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508 and IEC 13849-1 standards. Accessories (fan kit, graphic display terminal) and options (line chokes, dv/dt filter, sinus filter, EMC filter) are available with Altivar Process ATV600 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a wall. This new concept of drives meets the major needs of process and utilities in terms of equipment efficiency and total cost of ownership by supporting the energy management, asset management and also the overall performance of the process.
View AllClose