Schneider Electric ATV650D45N4U Atv650 Ip55 Ul Type12 45Kw 60Hp 400V/480
SKU:
ATV650D45N4U
UPC:
3.60648E+12
MPN:
Condition:
New
Data Format:
8 bits, configurable odd, even or no parity
Quantity Per Set:
1
Mercury Free:
Yes
Circularity Profile:
ENVEOLI1506001EN
Product Certifications:
ATEX INERIS || Bureau Veritas || ABS || DNV-GL || UL || TÃV
Accuracy:
+/- 1 % AO1, AO2 for a temperature variation 60 °C analog output || +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
Braking To Standstill:
by DC injection
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits || AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
Upgradeability:
Upgraded components available
Discrete Input Number:
8
Maximum Transient Current:
111.8 A 60 s heavy duty) || 96.8 A 60 s normal duty)
Local Signalling:
for embedded communication status 3 LEDs (dual colour) || for communication module status 4 LEDs (dual colour) || for presence of voltage 1 LED (red) || for local diagnostic 3 LEDs
Physical Interface:
Ethernet || 2-wire RS 485
Pollution Degree:
2 IEC 61800-5-1
Overvoltage Category:
III
Rohs Exemption Information:
Yes
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 10 bits || software-configurable current DQ-, DQ+ 30 V DC || software-configurable current DQ-, DQ+ 100 mA
Motor Power Kw:
37 kW heavy duty) || 45 kW normal duty)
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Range Of Product:
Altivar Process ATV600
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
China Rohs Regulation:
X
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Supply Frequency:
50...60 Hz - 5...5 %
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Operating Position:
vertical +/- 10 degree
Discrete Output Type:
relay outputs R1A, R1B, R1C 250 V AC 3000 mA || relay outputs R1A, R1B, R1C 30 V DC 3000 mA || relay outputs R2A, R2C 250 V AC 5000 mA || relay outputs R2A, R2C 30 V DC 5000 mA || relay outputs R3A, R3C 250 V AC 5000 mA || relay outputs R3A, R3C 30 V
Maximum Thdi:
<48 % from 80...100 % of load IEC 61000-3-12
Option Card:
slot A communication module, PROFINET || slot A communication module, DeviceNet || slot A communication module, Modbus TCP/EtherNet/IP || slot A communication module, CANopen daisy chain RJ45 || slot A communication module, CANopen SUB-D 9 || slot A
5 ms +/- 1 ms DI5, DI6) - discrete input || 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input || 10 ms +/- 1 ms AO1) - analog output || 2 ms +/- 0.5 ms DI1...DI4) - discrete input
Net Weight:
50 kg
Supply:
internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for digital inputs and STO 24 V DC 21-27 V), <200 mA overload and short-circuit protection || external suppl
Protection Type:
safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-circuit protection drive || m
Height:
910 mm
Enclosure Mounting:
wall mounted
Discrete Input Type:
DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
synchronous reluctance motor || permanent magnet motor
Number Of Addresses:
1-247 Modbus serial
Phase:
3 phase
Maximum Output Frequency:
500 kHz
Transmission Frame:
RTU
Pollution Degree:
3
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Product Destination:
asynchronous motors || synchronous motors
Maximum Horse Power Rating:
50 hp heavy duty || 60 hp normal duty
Ambient Air Temperature For Operation:
40-50 °C with derating factor) || -15-40 °C without derating)
Frequency Resolution:
analog input 0.012/50 Hz || display unit 0.1 Hz
Product Specific Application:
process and utilities
Width:
290 mm
Analogue Output Number:
2
Depth:
340 mm
Sustainable Offer Status:
Green Premium product
Vibration Resistance:
1 gn 13-200 Hz)IEC 60068-2-6 || 1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Relay Output Number:
3
Maximum Switching Current:
relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R1, R2, R3 resistive, cos phi = 1 3
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Noise Level:
69.7 dB
[Us] Rated Supply Voltage:
380...480 V
Line Current:
69.1 A 480 V normal duty) || 67.1 A 380 V heavy duty) || 59 A 480 V heavy duty) || 79.8 A 380 V normal duty)
Noise Level:
69.7 dB 86/188/EEC
Isolation:
between power and control terminals
Environmental Disclosure:
ENVPEP1506001EN
Operating Altitude:
1000...4800 m with current derating 1 % per 100 m || <= 3280.84 ft (1000 m) without derating