Schneider Electric ATV650D55N4U Atv650 Ip55 Ul Type12 55Kw 75Hp 400V/480

(No reviews yet) Write a Review
SKU:
ATV650D55N4U
UPC:
3.61E+12
Condition:
New
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Device Short Name:
ATV650
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Communication Port Protocol:
Modbus TCP || Modbus serial
Method Of Access:
slave Modbus TCP
[Us] Rated Supply Voltage:
380...480 V - 15...10 %
Nominal Switching Frequency:
2.5 kHz
Transmission Rate:
10, 100 Mbits || 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Ambient Air Temperature For Storage:
-40-70 °C
Discrete Input Type:
DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
Frequency Resolution:
analog input 0.012/50 Hz || display unit 0.1 Hz
Enclosure Mounting:
wall mounted
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Net Weight:
87 kg
Ip Degree Of Protection:
IP55IEC 60529 || IP55IEC 61800-5-1
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s
Range Of Product:
Altivar Process ATV600
Standards:
IEC 61800-3 environment 1 category C2 || EN/IEC 61800-3 environment 2 category C3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1 || UL 508C
Relay Output Type:
configurable relay logic R2 sequence relay NO 100000 cycles || configurable relay logic R3 sequence relay NO 100000 cycles || configurable relay logic R1 fault relay NO/NC 100000 cycles
Local Signalling:
for embedded communication status 3 LEDs (dual colour) || for communication module status 4 LEDs (dual colour) || for presence of voltage 1 LED (red) || for local diagnostic 3 LEDs
Regulation Loop:
adjustable PID regulator
Depth:
375 mm
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V
Relay Output Number:
3
Discrete Input Logic:
16 preset speeds
Sustainable Offer Status:
Green Premium product
Permissible Temporary Current Boost:
1.5 x In 60 s heavy duty) || 1.1 x In 60 s normal duty)
Noise Level:
69.9 dB
Number Of Addresses:
1-247 Modbus serial
Supply Frequency:
50...60 Hz - 5...5 %
Line Current:
84.2 A 480 V normal duty) || 81.4 A 380 V heavy duty) || 71.8 A 480 V heavy duty) || 97.2 A 380 V normal duty)
Protection Type:
safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-circuit protection drive || m
Emc Filter:
integrated 150 m IEC 61800-3 category C3
Switching Frequency:
2...8 kHz adjustable || 2.5...8 kHz with derating factor
Electromagnetic Compatibility:
radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5 || conducted radio-frequency
Transmission Frame:
RTU
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Circularity Profile:
ENVEOLI1506002EN
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits || AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
Maximum Horse Power Rating:
60 hp heavy duty || 75 hp normal duty
Width:
345 mm
Type Of Cooling:
forced convection
Maximum Switching Current:
relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R1, R2, R3 resistive, cos phi = 1 3
Variant:
standard version
Motor Slip Compensation:
can be suppressed || adjustable || not available in permanent magnet motor law || automatic whatever the load
Electrical Connection:
line side screw terminal 70...95 mm² || motor screw terminal 70...120 mm² || control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16
Motor Power Kw:
45 kW heavy duty) || 55 kW normal duty)
Overvoltage Category:
III
Sampling Duration:
5 ms +/- 1 ms DI5, DI6) - discrete input || 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input || 10 ms +/- 1 ms AO1) - analog output || 2 ms +/- 0.5 ms DI1...DI4) - discrete input
Mercury Free:
Yes
Maximum Thdi:
<48 % from 80...100 % of load IEC 61000-3-12
Maximum Transient Current:
132 A 60 s heavy duty) || 116.6 A 60 s normal duty)
Discrete Input Number:
8
Supply:
internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for digital inputs and STO 24 V DC 21-27 V), <200 mA overload and short-circuit protection || external suppl
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Noise Level:
69.9 dB 86/188/EEC
Prospective Line Isc:
50 kA
Braking To Standstill:
by DC injection
Discrete Output Type:
relay outputs R1A, R1B, R1C 250 V AC 3000 mA || relay outputs R1A, R1B, R1C 30 V DC 3000 mA || relay outputs R2A, R2C 250 V AC 5000 mA || relay outputs R2A, R2C 30 V DC 5000 mA || relay outputs R3A, R3C 250 V AC 5000 mA || relay outputs R3A, R3C 30 V
Product Specific Application:
process and utilities
Pollution Degree:
3
Continuous Output Current:
87 A 2.5 kHz heavy duty || 106 A 2.5 kHz normal duty
Output Voltage:
<= power supply voltage
Analogue Output Number:
2
Accuracy:
+/- 1 % AO1, AO2 for a temperature variation 60 °C analog output || +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
Operating Position:
vertical +/- 10 degree
Linearity Error:
AO1, AO2 +/- 0.2 % analog output || AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
Vibration Resistance:
1 gn 13-200 Hz)IEC 60068-2-6 || 1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 10 bits || software-configurable current DQ-, DQ+ 30 V DC || software-configurable current DQ-, DQ+ 100 mA
Operating Altitude:
1000...4800 m with current derating 1 % per 100 m || <= 3280.84 ft (1000 m) without derating
Rohs Exemption Information:
Yes
Quantity Per Set:
1
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Option Card:
slot A communication module, PROFINET || slot A communication module, DeviceNet || slot A communication module, Modbus TCP/EtherNet/IP || slot A communication module, CANopen daisy chain RJ45 || slot A communication module, CANopen SUB-D 9 || slot A
Marking:
CE
[Us] Rated Supply Voltage:
380...480 V
Ambient Air Temperature For Operation:
40-50 °C with derating factor) || -15-40 °C without derating)
Product Certifications:
ATEX INERIS || TÜV || CSA || UL || Bureau Veritas || ABS
Height:
1250 mm
Mounting Mode:
wall mount
Asynchronous Motor Control Profile:
variable torque standard || constant torque standard
Synchronous Motor Control Profile:
synchronous reluctance motor || permanent magnet motor
Speed Drive Output Frequency:
0.1-500 Hz
Type Of Polarization:
no impedance
Physical Interface:
Ethernet || 2-wire RS 485
Degree Of Protection:
UL type 12 UL 508C
Discrete Output Number:
0
Environmental Disclosure:
ENVPEP1506002EN
Isolation:
between power and control terminals
Upgradeability:
Upgraded components available
Safety Function:
STO (safe torque off) SIL 3
Analogue Input Number:
3
Product Destination:
asynchronous motors || synchronous motors
Product Or Component Type:
variable speed drive
Apparent Power:
59.7 kVA 480 V heavy duty) || 70 kVA 480 V normal duty)
China Rohs Regulation:
X
Maximum Output Frequency:
500 kHz
Connector Type:
RJ45 on the remote graphic terminal)Modbus serial || RJ45 on the remote graphic terminal)Ethernet/Modbus TCP
Data Format:
8 bits, configurable odd, even or no parity
Phase:
3 phase
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Input Compatibility:
DI5, DI6 discrete input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2 || DI1...DI6 discrete input level 1 PLC IEC 61131-2
Pollution Degree:
2 IEC 61800-5-1
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric ATV650D55N4U Atv650 Ip55 Ul Type12 55Kw 75Hp 400V/480