Schneider Electric

Schneider Electric ATV930C31N4C Variable Speed Drive Ip00 315Kw 400V/480

(No reviews yet) Write a Review
SKU:
ATV930C31N4C
UPC:
3.61E+12
Condition:
New
Range Of Product:
Altivar Process ATV900
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Brake Chopper Integrated:
FALSE
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
[Us] Rated Supply Voltage:
380...480 V - 15...10 %
Discrete Input Logic:
16 preset speeds
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI8) - discrete input || 5 ms +/- 1 ms DI7, DI8) - pulse input || 1 ms +/- 1 ms AI1, AI2, AI3) - analog input || 5 ms +/- 1 ms AQ1, AQ2) - analog output
Discrete Output Number:
2
Power Dissipation In W:
forced convection 7099 W 380 V 2.5 kHz || natural convection 769 W 380 V 2.5 kHz
Type Of Polarization:
no impedance Modbus serial
With Safety Function Safe Direction (Sdi):
FALSE
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Rohs Exemption Information:
Yes
Quantity Per Set:
1
With Safety Function Safe Speed Monitor (Ssm):
FALSE
Base Load Current At Low Overload:
616.0 A
Input Compatibility:
DI1...DI8 discrete input level 1 PLC IEC 61131-2 || DI7, DI8 pulse input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
Overvoltage Category:
III
Phase:
3 phase
Volume Of Cooling Air:
1260 m3/h
Maximum Transient Current:
739 A 60 s normal duty) || 722 A 60 s heavy duty)
Method Of Access:
slave Modbus TCP
Width:
598 mm
Communication Port Protocol:
EtherNet/IP || Modbus serial || Modbus TCP
Transmission Rate:
10, 100 Mbits || 4.8 kbps || 9600 bit/s || 19200 bit/s
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
Maximum Output Voltage:
480.0 V
Upgradeability:
Upgraded components available
Number Of Addresses:
1-247
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Maximum Acceleration Under Shock Impact (During Operation):
150 m/s² at 11 ms
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AQ1, AQ2 +/- 0.2 % analog output
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 3280.84...9842.52 ft (1000...3000 m) with current derating 1 % per 100 m
Maximum Acceleration Under Vibrational Stress (During Operation):
10 m/s² at 13...200 Hz
Data Format:
8 bits, configurable odd, even or no parity
Relative Symmetric Network Frequency Tolerance:
0.05
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
Electrical Connection:
control screw terminal 0.5...1.5 mm² AWG 20...AWG 16 || line side screw terminal 4 x 185 mm² 3 x 350 kcmil || motor screw terminal 4 x 185 mm² 3 x 350 kcmil || DC bus screw terminal 4 x 185 mm² 3 x 350 kcmil
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s
Ambient Air Transport Temperature:
-25-70 °C
Option Card:
slot A communication module Profibus DP V1 || slot A communication module PROFINET || slot A communication module DeviceNet || slot A communication module EtherCAT || slot A communication module CANopen daisy chain RJ45 || slot A communication module
Braking To Standstill:
by DC injection
Line Current:
569.0 A 380 V normal duty) || 457.0 A 380 V heavy duty) || 461.0 A 480 V normal duty) || 375.0 A 480 V heavy duty)
Nominal Switching Frequency:
2.5 kHz
Product Destination:
asynchronous motors || synchronous motors
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Switching Frequency:
1...8 kHz adjustable || 2.5...8 kHz with derating factor
With Safety Function Safe Operating Stop (Sos):
FALSE
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
China Rohs Regulation:
X
Standards:
UL 508C || IEC 61800-3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 1000000 cycles || configurable relay logic R3 sequence relay NO 1000000 cycles
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Maximum Switching Current:
relay output R1 resistive, cos phi = 1 3 A 250 V AC || relay output R1 resistive, cos phi = 1 3 A 30 V DC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2, R
Noise Level:
76 dB 86/188/EEC
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Motor Power Kw:
315.0 kW normal duty || 250.0 kW heavy duty
Emc Filter:
integrated || with EMC plate option
Mounting Mode:
wall mount
With Sft Fct Safe Stop 2 (Ss2):
FALSE
Operating Position:
vertical +/- 10 degree
With Safety Function Safe Torque Off (Sto):
TRUE
Transmission Frame:
RTU
With Safety Function Safe Programmable Logic:
FALSE
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V || positive logic (source) DI7, DI8), < 0.6 V, > 2.5 V || positive logic (source) STOA, STOB), < 5 V, > 11 V
Degree Of Protection:
UL type 1
Marking:
CE
With Safety Function Safe Brake Management (Sbc/Sbt):
TRUE
Apparent Power:
351 kVA 480 V normal duty) || 286 kVA 480 V heavy duty)
4 Quadrant Operation Possible:
FALSE
Discrete Input Number:
10
Ambient Air Temperature For Operation:
-10-40 °C without derating) || 40-60 °C with derating factor)
Type Of Polarization:
no impedance
Device Application:
Industrial Application
Discrete Output Type:
logic output DQ+ 0-1 kHz <= 30 V DC 100 mA || programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA || logic output DQ- 0-1 kHz <= 30 V DC 100 mA
Maximum Deflection Under Vibratory Load (During Operation):
1.5 mm at 2...13 Hz
Analogue Output Number:
2
Environmental Class (During Operation):
class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
Ip Degree Of Protection:
IP21
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Maximum Thdi:
<48 % full load IEC 61000-3-12
Product Certifications:
CSA || UL || TÜV
With Safety Function Safe Position (Sp):
FALSE
Transmission Rate:
10/100 Mbit/s Ethernet IP/Modbus TCP || 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
Assembly Style:
enclosed
Maximum Output Frequency:
599 Hz
Analogue Input Number:
3
With Safety Function Safely Limited Speed (Sls):
TRUE
Depth:
380 mm
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Height:
1195 mm
Product Or Component Type:
variable speed drive
Asynchronous Motor Control Profile:
variable torque standard || constant torque standard || optimized torque mode
Motor Slip Compensation:
not available in permanent magnet motor law || automatic whatever the load || can be suppressed || adjustable
Ambient Air Temperature For Storage:
-25-70 °C
With Safety Function Safely Limited Position (Slp):
FALSE
Noise Level:
76 dB
Continuous Output Current:
616 A 2.5 kHz normal duty || 481 A 2.5 kHz heavy duty
Environmental Characteristic:
chemical pollution resistance class 3C2 IEC 60721-3-3 || dust pollution resistance class 3S2 IEC 60721-3-3
Mercury Free:
Yes
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
With Safety Function Safe Stop 1 (Ss1):
TRUE
Pollution Degree:
2
Local Signalling:
local diagnostic 3 LED mono/dual colour) || presence of voltage 1 LED red) || embedded communication status 3 LED dual colour) || communication module status 4 LED dual colour)
Permitted Relative Humidity (During Operation):
class 3K5 according to EN 60721-3
Number Of Addresses:
1-247 Modbus serial
Prospective Line Isc:
50 kA
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Connector Type:
2 RJ45 || 1 RJ45
Product Specific Application:
process for industrial
Relay Output Number:
3
Base Load Current At High Overload:
481.0 A
Discrete Input Type:
DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm || DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) || STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
Physical Interface:
Ethernet || 2-wire RS 485
Net Weight:
203 kg
Network Frequency:
50-60 Hz
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Isolation:
between power and control terminals
Variant:
without braking chopper || standard version
Data Format:
8 bits, configurable odd, even or no parity Modbus serial
Regulation Loop:
adjustable PID regulator
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Brochure:
View
Datasheet:
View
$52,069.88

Description

This Altivar Process ATV900 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It is suitable for motors with power rating up to 315kW/500hp for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 250kW/400hp for applications requiring significant overload (up to 150%). It works at a rated supply voltage from 380V to 480V AC. This variable speed / frequency drive (VSD / VFD) is specifically designed for industrial processes. In the following market segments, oil and gas, mining, minerals and metals, food and beverage water and wastewater. It offers high motor performance on any motor and total control of any kind of coupling in master/slave applications. Network services help ensure operation continuity even in case of connection breakdown. Web server and data logging help reduce downtime through fast troubleshooting and preventive maintenance. Its advanced connectivity, including EtherNet/IP and Modbus TCP, allows deep integration into automation architectures. It is designed to be mounted in vertical position (+/- 10 °) on a wall.