Schneider Electric ATV930D11M3 Atv930 Ip21 11Kw 200V/240V Variable Spee

(No reviews yet) Write a Review
SKU:
ATV930D11M3
UPC:
3606480883613
Condition:
New
Height:
545.9 mm
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Braking To Standstill:
by DC injection
Width:
211 mm
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Apparent Power:
13.7 kVA 240 V normal duty) || 9.6 kVA 240 V heavy duty)
Regulation Loop:
adjustable PID regulator
Net Weight:
13.8 kg
Maximum Output Frequency:
599 Hz
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
Switching Frequency:
2...16 kHz adjustable || 4...16 kHz with derating factor
Connector Type:
2 RJ45 || 1 RJ45
Discrete Input Number:
10
With Safety Function Safely Limited Speed (Sls):
TRUE
Maximum Thdi:
<48 % from 80...100 % of load IEC 61000-3-12
Product Or Component Type:
variable speed drive
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Nominal Switching Frequency:
4 kHz
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Continuous Output Current:
46.8 A 4 kHz normal duty || 32.7 A 4 kHz heavy duty
With Safety Function Safe Programmable Logic:
FALSE
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
Physical Interface:
Ethernet || 2-wire RS 485
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Maximum Output Voltage:
240.0 V
Volume Of Cooling Air:
215 m3/h
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Analogue Output Number:
2
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AQ1, AQ2 +/- 0.2 % analog output
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Overvoltage Category:
III
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Motor Power Kw:
11.0 kW normal duty || 7.5 kW heavy duty
Base Load Current At High Overload:
32.7 A
Number Of Addresses:
1-247 Modbus serial
Asynchronous Motor Control Profile:
optimized torque mode || variable torque standard || constant torque standard
Maximum Deflection Under Vibratory Load (During Operation):
1.5 mm at 2...13 Hz
4 Quadrant Operation Possible:
TRUE
Maximum Acceleration Under Vibrational Stress (During Operation):
10 m/s² at 13...200 Hz
Emc Filter:
integrated || with EMC plate option
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 1000000 cycles || configurable relay logic R3 sequence relay NO 1000000 cycles
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Transmission Rate:
10/100 Mbit/s Ethernet IP/Modbus TCP || 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
Data Format:
8 bits, configurable odd, even or no parity
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Product Destination:
synchronous motors || asynchronous motors
Relay Output Number:
3
With Safety Function Safely Limited Position (Slp):
FALSE
Type Of Polarization:
no impedance Modbus serial
Discrete Output Number:
2
Product Certifications:
TÜV || CSA || UL
Maximum Transient Current:
56.2 A 60 s normal duty) || 49.1 A 60 s heavy duty)
Maximum Acceleration Under Shock Impact (During Operation):
150 m/s² at 11 ms
Data Format:
8 bits, configurable odd, even or no parity Modbus serial
Environmental Class (During Operation):
class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
Ambient Air Temperature For Storage:
-40-70 °C
Base Load Current At Low Overload:
46.8 A
Marking:
CE
Number Of Addresses:
1-247
Discrete Output Type:
logic output DQ+ 0-1 kHz <= 30 V DC 100 mA || programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA || logic output DQ- 0-1 kHz <= 30 V DC 100 mA
Degree Of Protection:
UL type 1
Analogue Input Number:
3
Ip Degree Of Protection:
IP21
Device Application:
Industrial Application
Noise Level:
59.5 dB
Transmission Rate:
10, 100 Mbits || 4.8 kbps || 9600 bit/s || 19200 bit/s
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Prospective Line Isc:
50 kA
Communication Port Protocol:
Modbus TCP || Modbus serial || EtherNet/IP
With Safety Function Safe Direction (Sdi):
FALSE
Network Frequency:
50-60 Hz
Quantity Per Set:
1
Brake Chopper Integrated:
TRUE
Option Card:
slot A communication module Profibus DP V1 || slot A communication module PROFINET || slot A communication module DeviceNet || slot A communication module EtherCAT || slot A communication module CANopen daisy chain RJ45 || slot A communication module
Relative Symmetric Network Frequency Tolerance:
0.05
With Safety Function Safe Brake Management (Sbc/Sbt):
TRUE
Line Current:
39.3 A 200 V normal duty) || 27.2 A 200 V heavy duty) || 32.9 A 240 V normal duty) || 23.1 A 240 V heavy duty)
Isolation:
between power and control terminals
Power Dissipation In W:
natural convection 62 W 200 V 4 kHz || forced convection 452 W 200 V 4 kHz
With Safety Function Safe Stop 1 (Ss1):
TRUE
Motor Slip Compensation:
not available in permanent magnet motor law || can be suppressed || adjustable || automatic whatever the load
Maximum Switching Current:
relay output R1 resistive, cos phi = 1 3 A 250 V AC || relay output R1 resistive, cos phi = 1 3 A 30 V DC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2, R
Environmental Characteristic:
chemical pollution resistance class 3C3 IEC 60721-3-3 || dust pollution resistance class 3S3 IEC 60721-3-3
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
With Safety Function Safe Torque Off (Sto):
TRUE
Pollution Degree:
2
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Environmental Disclosure:
ENVPEP1404008EN
Mercury Free:
Yes
China Rohs Regulation:
X
Method Of Access:
slave Modbus TCP
Circularity Profile:
ENVEOLI1404008EN
Operating Position:
vertical +/- 10 degree
Transmission Frame:
RTU
Discrete Input Type:
DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm || DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) || STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
Variant:
standard version || with braking chopper
Noise Level:
59.5 dB 86/188/EEC
Type Of Polarization:
no impedance
Phase:
3 phase
With Sft Fct Safe Stop 2 (Ss2):
FALSE
Input Compatibility:
DI1...DI8 discrete input level 1 PLC IEC 61131-2 || DI7, DI8 pulse input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
Rohs Exemption Information:
Yes
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V || positive logic (source) DI7, DI8), < 0.6 V, > 2.5 V || positive logic (source) STOA, STOB), < 5 V, > 11 V
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI8) - discrete input || 5 ms +/- 1 ms DI7, DI8) - pulse input || 1 ms +/- 1 ms AI1, AI2, AI3) - analog input || 5 ms +/- 1 ms AQ1, AQ2) - analog output
Electrical Connection:
control screw terminal 0.5...1.5 mm² AWG 20...AWG 16 || line side screw terminal 10...16 mm² AWG 8...AWG 6 || DC bus screw terminal 10...16 mm² AWG 8...AWG 6 || motor screw terminal 16 mm² AWG 6
With Safety Function Safe Operating Stop (Sos):
FALSE
Sustainable Offer Status:
Green Premium product
Discrete Input Logic:
16 preset speeds
Range Of Product:
Altivar Process ATV900
With Safety Function Safe Position (Sp):
FALSE
Depth:
235 mm
Permitted Relative Humidity (During Operation):
class 3K5 according to EN 60721-3
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Assembly Style:
enclosed
Standards:
UL 508C || IEC 61800-3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
With Safety Function Safe Speed Monitor (Ssm):
FALSE
[Us] Rated Supply Voltage:
200...240 V - 15...10 %
Mounting Mode:
wall mount
Upgradeability:
Upgraded components available
Product Specific Application:
process for industrial
Local Signalling:
local diagnostic 3 LED mono/dual colour) || embedded communication status 5 LED dual colour) || communication module status 2 LED dual colour) || presence of voltage 1 LED red)
Ambient Air Transport Temperature:
-40-70 °C
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric ATV930D11M3 Atv930 Ip21 11Kw 200V/240V Variable Spee
  • Schneider Electric ATV930D11M3 Atv930 Ip21 11Kw 200V/240V Variable Spee
  • Schneider Electric ATV930D11M3 Atv930 Ip21 11Kw 200V/240V Variable Spee
$3,830.60

Description

This Altivar Process ATV900 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It is suitable for motors with power rating up to 11kW/15HP for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 7.5kW/10HP for applications requiring significant overload (up to 150%). It works at a rated supply voltage from 200Vac to 240Vac. This variable speed / frequency drive (VSD / VFD) is specifically designed for industrial processes. In the following market segments: oil and gas, mining, minerals and metals, food and beverage water and wastewater. It offers high motor performance on any motor and total control of any kind of coupling in master/slave applications. Network services help ensure operation continuity even in case of connection breakdown. Web server and data logging help reduce downtime through fast troubleshooting and preventive maintenance. Its advanced connectivity, including EtherNet/IP and Modbus TCP, allows deep integration into automation architectures.
View AllClose