adjustable || automatic whatever the load || not available in permanent magnet motor law || can be suppressed
Base Load Current At Low Overload:
39.2 A
Circularity Profile:
ENVEOLI2007011EN
Analogue Output Number:
2
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
With Safety Function Safe Operating Stop (Sos):
FALSE
With Safety Function Safe Torque Off (Sto):
TRUE
Discrete Input Number:
10
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
relay output R1 resistive, cos phi = 1 3 A 250 V AC || relay output R1 resistive, cos phi = 1 3 A 30 V DC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2, R
Maximum Thdi:
<48 % from 80...100 % of load IEC 61000-3-12
Analogue Input Number:
3
Option Card:
slot A communication module Profibus DP V1 || slot A communication module PROFINET || slot A communication module DeviceNet || slot A communication module EtherCAT || slot A communication module CANopen daisy chain RJ45 || slot A communication module
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AQ1, AQ2 +/- 0.2 % analog output
Pollution Degree:
2
Transmission Frame:
RTU
Number Of Addresses:
1-247
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
With Safety Function Safe Position (Sp):
FALSE
Network Frequency:
50-60 Hz
Discrete Input Type:
DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm || DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) || STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
Mounting Mode:
cabinet mount
With Sft Fct Safe Stop 2 (Ss2):
FALSE
Nominal Switching Frequency:
4 kHz
Degree Of Protection:
UL type 12
Sustainable Offer Status:
Green Premium product
With Safety Function Safe Speed Monitor (Ssm):
FALSE
Isolation:
between power and control terminals
Environmental Characteristic:
chemical pollution resistance class 3C3 IEC 60721-3-3 || dust pollution resistance class 3S3 IEC 60721-3-3
Product Or Component Type:
variable speed drive
Prospective Line Isc:
50 kA
Product Certifications:
UL || TÃV || CSA
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s
Variant:
with braking chopper || standard version
Range Of Product:
Altivar Process ATV900
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Net Weight:
13.6 kg
Switching Frequency:
2...16 kHz adjustable || 4...16 kHz with derating factor
Maximum Deflection Under Vibratory Load (During Operation):
1.5 mm at 2...13 Hz
Product Specific Application:
process for industrial
Product Destination:
asynchronous motors || synchronous motors
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
39.2 A 4 kHz normal duty || 31.7 A 4 kHz heavy duty
China Rohs Regulation:
X
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Brake Chopper Integrated:
TRUE
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Quantity Per Set:
1
With Safety Function Safely Limited Position (Slp):
FALSE
Environmental Class (During Operation):
class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
Maximum Output Voltage:
480.0 V
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI8) - discrete input || 5 ms +/- 1 ms DI7, DI8) - pulse input || 1 ms +/- 1 ms AI1, AI2, AI3) - analog input || 5 ms +/- 1 ms AQ1, AQ2) - analog output
local diagnostic 3 LED mono/dual colour) || embedded communication status 5 LED dual colour) || communication module status 2 LED dual colour) || presence of voltage 1 LED red)
With Safety Function Safely Limited Speed (Sls):
TRUE
Number Of Addresses:
1-247 Modbus serial
Base Load Current At High Overload:
31.7 A
Upgradeability:
Upgraded components available
Type Of Polarization:
no impedance
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Mercury Free:
Yes
Apparent Power:
24 kVA 480 V normal duty) || 20.3 kVA 480 V heavy duty)
Regulation Loop:
adjustable PID regulator
Permitted Relative Humidity (During Operation):
class 3K5 according to EN 60721-3
Ambient Air Transport Temperature:
-40-70 °C
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
8 bits, configurable odd, even or no parity Modbus serial
With Safety Function Safe Brake Management (Sbc/Sbt):
TRUE
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
Power Dissipation In W:
natural convection 67 W 380 V 4 kHz || forced convection 460 W 380 V 4 kHz
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Overvoltage Category:
III
Communication Port Protocol:
Modbus TCP || EtherNet/IP || Modbus serial
Electrical Connection:
control screw terminal 0.5...1.5 mm² AWG 20...AWG 16 || line side screw terminal 10...16 mm² AWG 8...AWG 6 || motor screw terminal 10...16 mm² AWG 8...AWG 6 || DC bus screw terminal 10...16 mm² AWG 8...AWG 6
Maximum Acceleration Under Shock Impact (During Operation):
150 m/s² at 11 ms
Method Of Access:
slave Modbus TCP
Discrete Input Logic:
16 preset speeds
Discrete Output Type:
logic output DQ+ 0-1 kHz <= 30 V DC 100 mA || programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA || logic output DQ- 0-1 kHz <= 30 V DC 100 mA
Motor Power Kw:
18.5 kW normal duty || 15.0 kW heavy duty
Maximum Acceleration Under Vibrational Stress (During Operation):
10 m/s² at 13...200 Hz
With Safety Function Safe Programmable Logic:
FALSE
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Line Current:
33.4 A 380 V normal duty) || 27.7 A 380 V heavy duty) || 28.9 A 480 V normal duty) || 24.4 A 480 V heavy duty)
4 Quadrant Operation Possible:
TRUE
Environmental Disclosure:
ENVPEP2007011EN
Relay Output Number:
3
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Relative Symmetric Network Frequency Tolerance:
0.05
With Safety Function Safe Stop 1 (Ss1):
TRUE
Asynchronous Motor Control Profile:
constant torque standard || variable torque standard || optimized torque mode