Schneider Electric ATV930U55M3 Atv930 Ip21 5,5Kw 200V/240V Variable Spe

(No reviews yet) Write a Review
SKU:
ATV930U55M3
UPC:
3606480883590
Condition:
New
Overvoltage Category:
III
Switching Frequency:
2...16 kHz adjustable || 4...16 kHz with derating factor
Phase:
3 phase
Device Application:
Industrial Application
With Safety Function Safely Limited Position (Slp):
FALSE
With Safety Function Safe Position (Sp):
FALSE
Discrete Output Number:
2
Marking:
CE
Range Of Product:
Altivar Process ATV900
Mounting Mode:
wall mount
Height:
409 mm
Prospective Line Isc:
50 kA
Assembly Style:
enclosed
Ambient Air Transport Temperature:
-40-70 °C
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AQ1, AQ2 +/- 0.2 % analog output
Degree Of Protection:
UL type 1
Local Signalling:
local diagnostic 3 LED mono/dual colour) || embedded communication status 5 LED dual colour) || communication module status 2 LED dual colour) || presence of voltage 1 LED red)
Braking To Standstill:
by DC injection
Data Format:
8 bits, configurable odd, even or no parity
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Input Compatibility:
DI1...DI8 discrete input level 1 PLC IEC 61131-2 || DI7, DI8 pulse input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
China Rohs Regulation:
X
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Physical Interface:
Ethernet || 2-wire RS 485
Transmission Rate:
10, 100 Mbits || 4.8 kbps || 9600 bit/s || 19200 bit/s
Maximum Switching Current:
relay output R1 resistive, cos phi = 1 3 A 250 V AC || relay output R1 resistive, cos phi = 1 3 A 30 V DC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2, R
With Safety Function Safe Speed Monitor (Ssm):
FALSE
Maximum Transient Current:
30.5 A 60 s normal duty) || 28.1 A 60 s heavy duty)
Maximum Acceleration Under Vibrational Stress (During Operation):
10 m/s² at 13...200 Hz
With Safety Function Safely Limited Speed (Sls):
TRUE
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 1000000 cycles || configurable relay logic R3 sequence relay NO 1000000 cycles
With Safety Function Safe Programmable Logic:
FALSE
Apparent Power:
7.6 kVA 240 V normal duty) || 6 kVA 240 V heavy duty)
Communication Port Protocol:
Modbus TCP || EtherNet/IP || Modbus serial
Discrete Input Type:
DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm || DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) || STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Electrical Connection:
control screw terminal 0.5...1.5 mm² AWG 20...AWG 16 || line side screw terminal 6 mm² AWG 10 || DC bus screw terminal 6 mm² AWG 10 || motor screw terminal 10 mm² AWG 8
Maximum Acceleration Under Shock Impact (During Operation):
150 m/s² at 11 ms
With Safety Function Safe Brake Management (Sbc/Sbt):
TRUE
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V || positive logic (source) DI7, DI8), < 0.6 V, > 2.5 V || positive logic (source) STOA, STOB), < 5 V, > 11 V
Analogue Output Number:
2
With Safety Function Safe Stop 1 (Ss1):
TRUE
Data Format:
8 bits, configurable odd, even or no parity Modbus serial
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
Relative Symmetric Network Frequency Tolerance:
0.05
Continuous Output Current:
25.4 A 4 kHz normal duty || 18.7 A 4 kHz heavy duty
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Pollution Degree:
2
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Power Dissipation In W:
natural convection 47 W 200 V 4 kHz || forced convection 179 W 200 V 4 kHz
Width:
171 mm
Method Of Access:
slave Modbus TCP
Relay Output Number:
3
Net Weight:
7.7 kg
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Motor Power Kw:
5.5 kW normal duty || 4.0 kW heavy duty
Line Current:
20.2 A 200 V normal duty) || 15.1 A 200 V heavy duty) || 17.1 A 240 V normal duty) || 13.0 A 240 V heavy duty)
Network Frequency:
50-60 Hz
With Safety Function Safe Operating Stop (Sos):
FALSE
Maximum Output Voltage:
240.0 V
Product Specific Application:
process for industrial
Permitted Relative Humidity (During Operation):
class 3K5 according to EN 60721-3
Ip Degree Of Protection:
IP21
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Mercury Free:
Yes
Discrete Input Number:
10
Base Load Current At High Overload:
18.7 A
Type Of Polarization:
no impedance
4 Quadrant Operation Possible:
TRUE
Transmission Frame:
RTU
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Type Of Polarization:
no impedance Modbus serial
With Safety Function Safe Torque Off (Sto):
TRUE
Asynchronous Motor Control Profile:
variable torque standard || constant torque standard || optimized torque mode
[Us] Rated Supply Voltage:
200...240 V - 15...10 %
Base Load Current At Low Overload:
25.4 A
Number Of Addresses:
1-247
Volume Of Cooling Air:
103 m3/h
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Depth:
236 mm
Option Card:
slot A communication module Profibus DP V1 || slot A communication module PROFINET || slot A communication module DeviceNet || slot A communication module EtherCAT || slot A communication module CANopen daisy chain RJ45 || slot A communication module
Product Or Component Type:
variable speed drive
Product Destination:
asynchronous motors || synchronous motors
Ambient Air Temperature For Storage:
-40-70 °C
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI8) - discrete input || 5 ms +/- 1 ms DI7, DI8) - pulse input || 1 ms +/- 1 ms AI1, AI2, AI3) - analog input || 5 ms +/- 1 ms AQ1, AQ2) - analog output
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Environmental Disclosure:
ENVPEP1508010EN
Variant:
standard version || with braking chopper
Emc Filter:
integrated || with EMC plate option
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Noise Level:
56 dB
Environmental Characteristic:
chemical pollution resistance class 3C3 IEC 60721-3-3 || dust pollution resistance class 3S3 IEC 60721-3-3
Maximum Output Frequency:
599 Hz
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
Discrete Input Logic:
16 preset speeds
Environmental Class (During Operation):
class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
With Safety Function Safe Direction (Sdi):
FALSE
Product Certifications:
UL || TÜV || CSA
Upgradeability:
Upgraded components available
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Circularity Profile:
ENVEOLI1508010EN
Maximum Thdi:
<48 % from 80...100 % of load IEC 61000-3-12
Standards:
UL 508C || IEC 61800-3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Nominal Switching Frequency:
4 kHz
With Sft Fct Safe Stop 2 (Ss2):
FALSE
Discrete Output Type:
logic output DQ+ 0-1 kHz <= 30 V DC 100 mA || programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA || logic output DQ- 0-1 kHz <= 30 V DC 100 mA
Quantity Per Set:
1
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Sustainable Offer Status:
Green Premium product
Connector Type:
2 RJ45 || 1 RJ45
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Regulation Loop:
adjustable PID regulator
Rohs Exemption Information:
Yes
Operating Position:
vertical +/- 10 degree
Analogue Input Number:
3
Motor Slip Compensation:
adjustable || automatic whatever the load || can be suppressed || not available in permanent magnet motor law
Maximum Deflection Under Vibratory Load (During Operation):
1.5 mm at 2...13 Hz
Isolation:
between power and control terminals
Number Of Addresses:
1-247 Modbus serial
Transmission Rate:
10/100 Mbit/s Ethernet IP/Modbus TCP || 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
Brake Chopper Integrated:
TRUE
Noise Level:
56 dB 86/188/EEC
Brochure:
View
Datasheet:
View
  • Schneider Electric ATV930U55M3 Atv930 Ip21 5,5Kw 200V/240V Variable Spe
  • Schneider Electric ATV930U55M3 Atv930 Ip21 5,5Kw 200V/240V Variable Spe
  • Schneider Electric ATV930U55M3 Atv930 Ip21 5,5Kw 200V/240V Variable Spe
$2,662.49

Description

This Altivar Process ATV900 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It is suitable for motors with power rating up to 5.5kW/7.5HP for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 4kW/5HP for applications requiring significant overload (up to 150%). It works at a rated supply voltage from 200Vac to 240Vac. This variable speed / frequency drive (VSD / VFD) is specifically designed for industrial processes. In the following market segments, oil and gas, mining, minerals and metals, food and beverage water and wastewater. It offers high motor performance on any motor and total control of any kind of coupling in master/slave applications. Network services help ensure operation continuity even in case of connection breakdown. Web server and data logging help reduce downtime through fast troubleshooting and preventive maintenance. Its advanced connectivity, including EtherNet/IP and Modbus TCP, allows deep integration into automation architectures.
View AllClose