Schneider Electric ATV950D22N4U Atv950 Ip55 Ultype12 22Kw 400V/480V Vari

(No reviews yet) Write a Review
SKU:
ATV950D22N4U
UPC:
3.60648E+12
Condition:
New
4 Quadrant Operation Possible:
TRUE
Product Destination:
asynchronous motors || synchronous motors
Mounting Mode:
wall mount
Method Of Access:
slave Modbus TCP
Product Specific Application:
process for industrial
With Safety Function Safe Torque Off (Sto):
TRUE
Range Of Product:
Altivar Process ATV900
Emc Filter:
integrated || with EMC plate option
Sustainable Offer Status:
Green Premium product
Ambient Air Transport Temperature:
-40-70 °C
Environmental Disclosure:
ENVPEP1406001EN
Quantity Per Set:
1
Phase:
3 phase
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Local Signalling:
local diagnostic 3 LED mono/dual colour) || embedded communication status 5 LED dual colour) || communication module status 2 LED dual colour) || presence of voltage 1 LED red)
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 1000000 cycles || configurable relay logic R3 sequence relay NO 1000000 cycles
Standards:
UL 508C || IEC 61800-3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Maximum Switching Current:
relay output R1 resistive, cos phi = 1 3 A 250 V AC || relay output R1 resistive, cos phi = 1 3 A 30 V DC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2, R
Maximum Output Frequency:
599 Hz
Discrete Output Type:
logic output DQ+ 0-1 kHz <= 30 V DC 100 mA || programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA || logic output DQ- 0-1 kHz <= 30 V DC 100 mA
Operating Position:
vertical +/- 10 degree
Transmission Frame:
RTU
Noise Level:
53.7 dB
Net Weight:
20.6 kg
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AQ1, AQ2 +/- 0.2 % analog output
Motor Slip Compensation:
automatic whatever the load || not available in permanent magnet motor law || adjustable || can be suppressed
Analogue Input Number:
3
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Option Card:
slot A communication module Profibus DP V1 || slot A communication module PROFINET || slot A communication module DeviceNet || slot A communication module EtherCAT || slot A communication module CANopen daisy chain RJ45 || slot A communication module
Variant:
with braking chopper || standard version
Product Certifications:
Bureau Veritas || TÜV || CSA || ATEX INERIS || UL || DNV-GL || ABS
Maximum Transient Current:
55.6 A 60 s normal duty) || 58.8 A 60 s heavy duty)
Brake Chopper Integrated:
TRUE
Prospective Line Isc:
50 kA
Asynchronous Motor Control Profile:
optimized torque mode || constant torque standard || variable torque standard
Ambient Air Temperature For Operation:
-15-40 °C without derating) || 40-50 °C with derating factor)
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI8) - discrete input || 5 ms +/- 1 ms DI7, DI8) - pulse input || 1 ms +/- 1 ms AI1, AI2, AI3) - analog input || 5 ms +/- 1 ms AQ1, AQ2) - analog output
Discrete Output Number:
2
Connector Type:
2 RJ45 || 1 RJ45
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V || positive logic (source) DI7, DI8), < 0.6 V, > 2.5 V || positive logic (source) STOA, STOB), < 5 V, > 11 V
Pollution Degree:
2
Data Format:
8 bits, configurable odd, even or no parity
Maximum Acceleration Under Shock Impact (During Operation):
150 m/s² at 11 ms
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Discrete Input Type:
DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm || DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) || STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
Base Load Current At Low Overload:
46.3 A
Maximum Thdi:
<48 % from 80...100 % of load IEC 61000-3-12
Type Of Polarization:
no impedance Modbus serial
With Safety Function Safe Brake Management (Sbc/Sbt):
TRUE
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
With Safety Function Safe Operating Stop (Sos):
FALSE
Ip Degree Of Protection:
IP55
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
With Safety Function Safe Direction (Sdi):
FALSE
Apparent Power:
28.6 kVA 480 V normal duty) || 24.9 kVA 480 V heavy duty)
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Transmission Rate:
10, 100 Mbits || 4.8 kbps || 9600 bit/s || 19200 bit/s
Number Of Addresses:
1-247
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
Ambient Air Temperature For Storage:
-40-70 °C
Maximum Output Voltage:
480.0 V
Device Application:
Industrial Application
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge immu
Noise Level:
53.7 dB 86/188/EEC
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Width:
264 mm
Discrete Input Number:
10
Type Of Polarization:
no impedance
Regulation Loop:
adjustable PID regulator
Base Load Current At High Overload:
39.2 A
Relative Symmetric Network Frequency Tolerance:
0.05
Marking:
CE
With Safety Function Safely Limited Speed (Sls):
TRUE
Rohs Exemption Information:
Yes
China Rohs Regulation:
X
With Safety Function Safe Position (Sp):
FALSE
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
With Safety Function Safe Speed Monitor (Ssm):
FALSE
Product Or Component Type:
variable speed drive
Environmental Class (During Operation):
class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
Electrical Connection:
control screw terminal 0.5...1.5 mm² AWG 20...AWG 16 || line side screw terminal 10...16 mm² AWG 8...AWG 6 || DC bus screw terminal 10...16 mm² AWG 8...AWG 6 || motor screw terminal 16 mm² AWG 6
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Maximum Acceleration Under Vibrational Stress (During Operation):
10 m/s² at 13...200 Hz
Maximum Deflection Under Vibratory Load (During Operation):
1.5 mm at 2...13 Hz
Braking To Standstill:
by DC injection
Environmental Characteristic:
chemical pollution resistance class 3C3 IEC 60721-3-3 || dust pollution resistance class 3S3 IEC 60721-3-3
Circularity Profile:
ENVEOLI1406001EN
With Sft Fct Safe Stop 2 (Ss2):
FALSE
With Safety Function Safely Limited Position (Slp):
FALSE
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Overvoltage Category:
III
Transmission Rate:
10/100 Mbit/s Ethernet IP/Modbus TCP || 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
Physical Interface:
Ethernet || 2-wire RS 485
Mercury Free:
Yes
[Us] Rated Supply Voltage:
380...480 V - 15...10 %
Switching Frequency:
2...16 kHz adjustable || 4...16 kHz with derating factor
With Safety Function Safe Programmable Logic:
FALSE
Degree Of Protection:
UL type 12
Data Format:
8 bits, configurable odd, even or no parity Modbus serial
Discrete Input Logic:
16 preset speeds
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Nominal Switching Frequency:
4 kHz
Depth:
299 mm
Network Frequency:
50-60 Hz
With Safety Function Safe Stop 1 (Ss1):
TRUE
Analogue Output Number:
2
Permitted Relative Humidity (During Operation):
class 3K5 according to EN 60721-3
Motor Power Kw:
22.0 kW normal duty || 18.5 kW heavy duty
Assembly Style:
enclosed
Continuous Output Current:
46.3 A 4 kHz normal duty || 39.2 A 4 kHz heavy duty
Number Of Addresses:
1-247 Modbus serial
Communication Port Protocol:
Modbus TCP || Modbus serial || EtherNet/IP
Upgradeability:
Upgraded components available
Relay Output Number:
3
Isolation:
between power and control terminals
Height:
678 mm
Input Compatibility:
DI1...DI8 discrete input level 1 PLC IEC 61131-2 || DI7, DI8 pulse input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
Line Current:
39.6 A 380 V normal duty) || 34.1 A 380 V heavy duty) || 34.4 A 480 V normal duty) || 29.9 A 480 V heavy duty)
  • Schneider Electric ATV950D22N4U Atv950 Ip55 Ultype12 22Kw 400V/480V Vari
  • Schneider Electric ATV950D22N4U Atv950 Ip55 Ultype12 22Kw 400V/480V Vari
$10,130.80

Description

variable speed drive, Altivar Process ATV900, ATV950, 22kW, 30hp, 380 to 480V, IP55, UL type 12
View AllClose