Schneider Electric ATV950D45N4U Atv950 Ip55 Ultype12 45Kw 400V/480V Vari

(No reviews yet) Write a Review
SKU:
ATV950D45N4U
UPC:
3.60648E+12
Condition:
New
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AQ1, AQ2 +/- 0.2 % analog output
Electrical Connection:
control screw terminal 0.5...1.5 mm² AWG 20...AWG 16 || line side screw terminal 35...50 mm² AWG 3...AWG 1 || DC bus screw terminal 35...50 mm² AWG 3...AWG 1 || motor screw terminal 35...50 mm² AWG 2...AWG 1
Switching Frequency:
2...16 kHz adjustable || 4...16 kHz with derating factor
Number Of Addresses:
1-247 Modbus serial
Isolation:
between power and control terminals
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Discrete Input Logic:
16 preset speeds
Motor Power Kw:
45.0 kW normal duty || 37.0 kW heavy duty
Ip Degree Of Protection:
IP55
Maximum Deflection Under Vibratory Load (During Operation):
1.5 mm at 2...13 Hz
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Depth:
340 mm
Range Of Product:
Altivar Process ATV900
Circularity Profile:
ENVEOLI1506001EN
Mercury Free:
Yes
Transmission Rate:
10, 100 Mbits || 4.8 kbps || 9600 bit/s || 19200 bit/s
With Safety Function Safe Programmable Logic:
FALSE
Motor Slip Compensation:
adjustable || can be suppressed || not available in permanent magnet motor law || automatic whatever the load
Discrete Output Type:
logic output DQ+ 0-1 kHz <= 30 V DC 100 mA || programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA || logic output DQ- 0-1 kHz <= 30 V DC 100 mA
Sustainable Offer Status:
Green Premium product
Maximum Output Frequency:
599 Hz
Base Load Current At Low Overload:
88.0 A
Data Format:
8 bits, configurable odd, even or no parity
Ambient Air Transport Temperature:
-40-70 °C
Standards:
UL 508C || IEC 61800-3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
With Safety Function Safe Stop 1 (Ss1):
TRUE
Permitted Relative Humidity (During Operation):
class 3K5 according to EN 60721-3
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s
Degree Of Protection:
UL type 12
Communication Port Protocol:
Modbus TCP || EtherNet/IP || Modbus serial
Line Current:
79.8 A 380 V normal duty) || 67.1 A 380 V heavy duty) || 69.1 A 480 V normal duty) || 59.0 A 480 V heavy duty)
Braking To Standstill:
by DC injection
Transmission Rate:
10/100 Mbit/s Ethernet IP/Modbus TCP || 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
Noise Level:
69.7 dB 86/188/EEC
Net Weight:
50 kg
Input Compatibility:
DI1...DI8 discrete input level 1 PLC IEC 61131-2 || DI7, DI8 pulse input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
Prospective Line Isc:
50 kA
With Sft Fct Safe Stop 2 (Ss2):
FALSE
Noise Level:
69.7 dB
Maximum Switching Current:
relay output R1 resistive, cos phi = 1 3 A 250 V AC || relay output R1 resistive, cos phi = 1 3 A 30 V DC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2, R
Product Certifications:
TÜV || ATEX INERIS || ABS || Bureau Veritas || CSA || UL || DNV-GL
Type Of Polarization:
no impedance Modbus serial
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Relative Symmetric Network Frequency Tolerance:
0.05
Transmission Frame:
RTU
Environmental Disclosure:
ENVPEP1506001EN
Phase:
3 phase
Connector Type:
2 RJ45 || 1 RJ45
Analogue Output Number:
2
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Device Application:
Industrial Application
Maximum Acceleration Under Vibrational Stress (During Operation):
10 m/s² at 13...200 Hz
Ambient Air Temperature For Operation:
-15-40 °C without derating) || 40-50 °C with derating factor)
Maximum Transient Current:
105.6 A 60 s normal duty) || 111.8 A 60 s heavy duty)
Brake Chopper Integrated:
TRUE
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
With Safety Function Safe Direction (Sdi):
FALSE
Environmental Class (During Operation):
class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
With Safety Function Safe Operating Stop (Sos):
FALSE
Operating Position:
vertical +/- 10 degree
With Safety Function Safely Limited Position (Slp):
FALSE
Emc Filter:
integrated || with EMC plate option
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Upgradeability:
Upgraded components available
Overvoltage Category:
III
Discrete Input Number:
10
Base Load Current At High Overload:
74.5 A
Assembly Style:
enclosed
Quantity Per Set:
1
Variant:
standard version || with braking chopper
China Rohs Regulation:
X
Height:
910 mm
Option Card:
slot A communication module Profibus DP V1 || slot A communication module PROFINET || slot A communication module DeviceNet || slot A communication module EtherCAT || slot A communication module CANopen daisy chain RJ45 || slot A communication module
Marking:
CE
Product Or Component Type:
variable speed drive
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Maximum Acceleration Under Shock Impact (During Operation):
150 m/s² at 11 ms
Number Of Addresses:
1-247
Analogue Input Number:
3
Maximum Thdi:
<48 % from 80...100 % of load IEC 61000-3-12
Width:
290 mm
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Discrete Input Type:
DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm || DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) || STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
Method Of Access:
slave Modbus TCP
Continuous Output Current:
88 A 4 kHz normal duty || 74.5 A 4 kHz heavy duty
Apparent Power:
57.4 kVA 480 V normal duty) || 49.1 kVA 480 V heavy duty)
4 Quadrant Operation Possible:
TRUE
With Safety Function Safe Position (Sp):
FALSE
Ambient Air Temperature For Storage:
-40-70 °C
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Environmental Characteristic:
chemical pollution resistance class 3C3 IEC 60721-3-3 || dust pollution resistance class 3S3 IEC 60721-3-3
Maximum Output Voltage:
480.0 V
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Type Of Polarization:
no impedance
Asynchronous Motor Control Profile:
variable torque standard || constant torque standard || optimized torque mode
Network Frequency:
50-60 Hz
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Product Destination:
asynchronous motors || synchronous motors
Physical Interface:
Ethernet || 2-wire RS 485
With Safety Function Safe Torque Off (Sto):
TRUE
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
Nominal Switching Frequency:
4 kHz
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V || positive logic (source) DI7, DI8), < 0.6 V, > 2.5 V || positive logic (source) STOA, STOB), < 5 V, > 11 V
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 1000000 cycles || configurable relay logic R3 sequence relay NO 1000000 cycles
With Safety Function Safe Brake Management (Sbc/Sbt):
TRUE
Rohs Exemption Information:
Yes
[Us] Rated Supply Voltage:
380...480 V - 15...10 %
Mounting Mode:
wall mount
With Safety Function Safe Speed Monitor (Ssm):
FALSE
Product Specific Application:
process for industrial
Local Signalling:
local diagnostic 3 LED mono/dual colour) || embedded communication status 5 LED dual colour) || communication module status 2 LED dual colour) || presence of voltage 1 LED red)
Data Format:
8 bits, configurable odd, even or no parity Modbus serial
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI8) - discrete input || 5 ms +/- 1 ms DI7, DI8) - pulse input || 1 ms +/- 1 ms AI1, AI2, AI3) - analog input || 5 ms +/- 1 ms AQ1, AQ2) - analog output
With Safety Function Safely Limited Speed (Sls):
TRUE
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Discrete Output Number:
2
Relay Output Number:
3
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
Regulation Loop:
adjustable PID regulator
Pollution Degree:
2
Catalog:
View
Datasheet:
View
  • Schneider Electric ATV950D45N4U Atv950 Ip55 Ultype12 45Kw 400V/480V Vari
  • Schneider Electric ATV950D45N4U Atv950 Ip55 Ultype12 45Kw 400V/480V Vari
$11,144.55

Description

variable speed drive, Altivar Process ATV900, ATV950, 45kW, 60hp, 380 to 480V, IP55, UL type 12
View AllClose