Schneider Electric ATV950U22N4EU Atv950 Ip55 Ultype12 2,2Kw 400V/480V Wit

(No reviews yet) Write a Review
SKU:
ATV950U22N4EU
UPC:
3606481284396
Condition:
New
Maximum Acceleration Under Vibrational Stress (During Operation):
10 m/s² at 13...200 Hz
Number Of Addresses:
1-247
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
[Us] Rated Supply Voltage:
380...480 V - 15...10 %
Product Or Component Type:
variable speed drive
With Safety Function Safely Limited Speed (Sls):
TRUE
Number Of Addresses:
1-247 Modbus serial
Electrical Connection:
control screw terminal 0.5...1.5 mm² || line side screw terminal 4...6 mm² || motor screw terminal 4...6 mm² || DC bus screw terminal 2.5...6 mm²
Data Format:
8 bits, configurable odd, even or no parity Modbus serial
Upgradeability:
Upgraded components available
Ambient Air Transport Temperature:
-40-70 °C
Product Destination:
synchronous motors || asynchronous motors
Relay Output Number:
3
Permitted Relative Humidity (During Operation):
class 3K5 according to EN 60721-3
Prospective Line Isc:
50 kA
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Product Specific Application:
process for industrial
Physical Interface:
Ethernet || 2-wire RS 485
Analogue Input Number:
3
Ambient Air Temperature For Operation:
-15-40 °C without derating) || 40-50 °C with derating factor)
Discrete Input Logic:
16 preset speeds
Mercury Free:
Yes
Variant:
with load break switch || with braking chopper
With Sft Fct Safe Stop 2 (Ss2):
FALSE
Marking:
CE
Ip Degree Of Protection:
IP55
Network Frequency:
50-60 Hz
Assembly Style:
enclosed
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Input Compatibility:
DI1...DI8 discrete input level 1 PLC IEC 61131-2 || DI7, DI8 pulse input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AQ1, AQ2 +/- 0.2 % analog output
Transmission Rate:
10/100 Mbit/s Ethernet IP/Modbus TCP || 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
Maximum Output Voltage:
480.0 V
Phase:
3 phase
Degree Of Protection:
UL type 12
Transmission Rate:
10, 100 Mbits || 4.8 kbps || 9600 bit/s || 19200 bit/s
Discrete Output Type:
logic output DQ+ 0-1 kHz <= 30 V DC 100 mA || programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA || logic output DQ- 0-1 kHz <= 30 V DC 100 mA
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
With Safety Function Safe Programmable Logic:
FALSE
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Nominal Switching Frequency:
4 kHz
Quantity Per Set:
1
Discrete Output Number:
2
Asynchronous Motor Control Profile:
variable torque standard || constant torque standard || optimized torque mode
Line Current:
4.3 A 380 V normal duty) || 3.1 A 380 V heavy duty) || 3.8 A 480 V normal duty) || 2.9 A 480 V heavy duty)
With Safety Function Safe Operating Stop (Sos):
FALSE
Overvoltage Category:
III
Range Of Product:
Altivar Process ATV900
Maximum Thdi:
<48 % full load IEC 61000-3-12
Environmental Disclosure:
ENVPEP1508009EN
Device Application:
Industrial Application
Communication Port Protocol:
Modbus serial || Modbus TCP || EtherNet/IP
With Safety Function Safe Stop 1 (Ss1):
TRUE
Net Weight:
10.5 kg
With Safety Function Safe Brake Management (Sbc/Sbt):
TRUE
Ambient Air Temperature For Storage:
-40-70 °C
Product Certifications:
CSA || ABS || ATEX INERIS || DNV-GL || UL || TÜV || Bureau Veritas
Data Format:
8 bits, configurable odd, even or no parity
Transmission Frame:
RTU
Noise Level:
52 dB
Maximum Switching Current:
relay output R1 resistive, cos phi = 1 3 A 250 V AC || relay output R1 resistive, cos phi = 1 3 A 30 V DC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2, R
Motor Slip Compensation:
automatic whatever the load || not available in permanent magnet motor law || can be suppressed || adjustable
Discrete Input Number:
10
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 1000000 cycles || configurable relay logic R3 sequence relay NO 1000000 cycles
Circularity Profile:
ENVEOLI1508009EN
Discrete Input Type:
DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm || DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) || STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge immu
Base Load Current At High Overload:
4.0 A
Mounting Mode:
wall mount
Apparent Power:
3.2 kVA 480 V normal duty) || 2.4 kVA 480 V heavy duty)
4 Quadrant Operation Possible:
TRUE
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Noise Level:
52 dB 86/188/EEC
Regulation Loop:
adjustable PID regulator
Continuous Output Current:
5.6 A 4 kHz normal duty || 4 A 4 kHz heavy duty
With Safety Function Safe Position (Sp):
FALSE
Base Load Current At Low Overload:
5.6 A
With Safety Function Safe Direction (Sdi):
FALSE
Pollution Degree:
2
Operating Position:
vertical +/- 10 degree
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Maximum Output Frequency:
599 Hz
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Switching Frequency:
2...16 kHz adjustable || 4...16 kHz with derating factor
China Rohs Regulation:
X
Height:
678 mm
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Relative Symmetric Network Frequency Tolerance:
0.05
Motor Power Kw:
2.2 kW normal duty || 1.5 kW heavy duty
Environmental Characteristic:
chemical pollution resistance class 3C3 IEC 60721-3-3 || dust pollution resistance class 3S3 IEC 60721-3-3
Brake Chopper Integrated:
TRUE
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
Analogue Output Number:
2
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Depth:
300 mm
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V || positive logic (source) DI7, DI8), < 0.6 V, > 2.5 V || positive logic (source) STOA, STOB), < 5 V, > 11 V
With Safety Function Safe Torque Off (Sto):
TRUE
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Emc Filter:
integrated || with EMC plate option
Maximum Acceleration Under Shock Impact (During Operation):
150 m/s² at 11 ms
Maximum Transient Current:
6.7 A 60 s normal duty) || 6 A 60 s heavy duty)
Braking To Standstill:
by DC injection
Width:
264 mm
Connector Type:
2 RJ45 || 1 RJ45
Maximum Deflection Under Vibratory Load (During Operation):
1.5 mm at 2...13 Hz
With Safety Function Safe Speed Monitor (Ssm):
FALSE
Isolation:
between power and control terminals
With Safety Function Safely Limited Position (Slp):
FALSE
Option Card:
slot A communication module Profibus DP V1 || slot A communication module PROFINET || slot A communication module DeviceNet || slot A communication module EtherCAT || slot A communication module CANopen daisy chain RJ45 || slot A communication module
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI8) - discrete input || 5 ms +/- 1 ms DI7, DI8) - pulse input || 1 ms +/- 1 ms AI1, AI2, AI3) - analog input || 5 ms +/- 1 ms AQ1, AQ2) - analog output
Type Of Polarization:
no impedance Modbus serial
Environmental Class (During Operation):
class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
Type Of Polarization:
no impedance
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Rohs Exemption Information:
Yes
Standards:
UL 508C || IEC 61800-3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Local Signalling:
local diagnostic 3 LED mono/dual colour) || embedded communication status 5 LED dual colour) || communication module status 2 LED dual colour) || presence of voltage 1 LED red)
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Sustainable Offer Status:
Green Premium product
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Method Of Access:
slave Modbus TCP
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
$4,081.38

Description

variable speed drive, Altivar Process ATV900, ATV950, 2.2kW, 3hp, 380 to 480V, IP55, UL type12, disconnect switch
View AllClose