Schneider Electric ATV950U40N4EU Atv950 Ip55 Ultype12 4Kw 400V/480V With
SKU:
ATV950U40N4EU
UPC:
3606481284419
MPN:
Condition:
New
Product Or Component Type:
variable speed drive
Product Destination:
synchronous motors || asynchronous motors
Analogue Output Number:
2
Switching Frequency:
2...16 kHz adjustable || 4...16 kHz with derating factor
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
Motor Slip Compensation:
not available in permanent magnet motor law || can be suppressed || automatic whatever the load || adjustable
Option Card:
slot A communication module Profibus DP V1 || slot A communication module PROFINET || slot A communication module DeviceNet || slot A communication module EtherCAT || slot A communication module CANopen daisy chain RJ45 || slot A communication module
With Sft Fct Safe Stop 2 (Ss2):
FALSE
Upgradeability:
Upgraded components available
Net Weight:
10.6 kg
Marking:
CE
Maximum Transient Current:
11.2 A 60 s normal duty) || 10.8 A 60 s heavy duty)
Type Of Polarization:
no impedance
Noise Level:
52 dB 86/188/EEC
Motor Power Kw:
4.0 kW normal duty || 3.0 kW heavy duty
With Safety Function Safely Limited Position (Slp):
FALSE
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Braking To Standstill:
by DC injection
Degree Of Protection:
UL type 12
Mercury Free:
Yes
Connector Type:
2 RJ45 || 1 RJ45
[Us] Rated Supply Voltage:
380...480 V - 15...10 %
With Safety Function Safe Position (Sp):
FALSE
Communication Port Protocol:
Modbus serial || EtherNet/IP || Modbus TCP
Transmission Frame:
RTU
Device Application:
Industrial Application
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
relay output R1 resistive, cos phi = 1 3 A 250 V AC || relay output R1 resistive, cos phi = 1 3 A 30 V DC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2, R
Mounting Mode:
wall mount
Base Load Current At High Overload:
7.2 A
Base Load Current At Low Overload:
9.3 A
Type Of Polarization:
no impedance Modbus serial
Electrical Connection:
control screw terminal 0.5...1.5 mm² || line side screw terminal 4...6 mm² || motor screw terminal 4...6 mm² || DC bus screw terminal 2.5...6 mm²
Emc Filter:
integrated || with EMC plate option
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Rohs Exemption Information:
Yes
Local Signalling:
local diagnostic 3 LED mono/dual colour) || embedded communication status 5 LED dual colour) || communication module status 2 LED dual colour) || presence of voltage 1 LED red)
With Safety Function Safe Operating Stop (Sos):
FALSE
Overvoltage Category:
III
Data Format:
8 bits, configurable odd, even or no parity
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
Variant:
with load break switch || with braking chopper
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI8) - discrete input || 5 ms +/- 1 ms DI7, DI8) - pulse input || 1 ms +/- 1 ms AI1, AI2, AI3) - analog input || 5 ms +/- 1 ms AQ1, AQ2) - analog output
Discrete Output Type:
logic output DQ+ 0-1 kHz <= 30 V DC 100 mA || programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA || logic output DQ- 0-1 kHz <= 30 V DC 100 mA
Environmental Characteristic:
chemical pollution resistance class 3C3 IEC 60721-3-3 || dust pollution resistance class 3S3 IEC 60721-3-3
Physical Interface:
Ethernet || 2-wire RS 485
Depth:
300 mm
Assembly Style:
enclosed
Data Format:
8 bits, configurable odd, even or no parity Modbus serial
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s
Product Certifications:
Bureau Veritas || TÃV || ABS || ATEX INERIS || CSA || DNV-GL || UL
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AQ1, AQ2 +/- 0.2 % analog output