Schneider Electric BDA161005 Molded Case Circuit Breaker 347V 100A

(No reviews yet) Write a Review
SKU:
BDA161005
UPC:
3606481151421
Condition:
New
Pvc Free:
Yes
Product Or Component Type:
circuit breaker
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Electrical Connection:
I-Line connection, line || lugs, load
Ip Degree Of Protection:
front cover IP40 IEC 60529
Tightening Torque:
3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)
Standards:
EN/IEC 60947-5-1 || UL 489 || NEMA AB1 || EN/IEC 60947-2 || CSA C22.2 No 5 || GB 14048.2 || NMX J-266
Wire Stripping Length:
20 mm
Pollution Degree:
3 IEC 60947-1
Phase Connection:
C
Rohs Exemption Information:
Yes
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
Height:
137 mm
Color:
Gray RAL 7016)
Product Name:
PowerPact B
Network Frequency:
50/60 Hz
Connection Pitch:
27 mm
Sustainable Offer Status:
Green Premium product
Continuous Current Rating:
0.8
[Ue] Rated Operational Voltage:
240 V AC 50/60 Hz UL 489
Poles Description:
1P
Mercury Free:
Yes
Breaking Capacity Code:
D
Control Type:
toggle
Trip Unit Technology:
thermal-magnetic
Environmental Disclosure:
ENVPEP1610005EN
Line Rated Current:
100-100 A
Device Application:
distribution
Circularity Profile:
N/A
Eu Rohs Directive:
Compliant with Exemptions
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
Depth:
89 mm
Utilisation Category:
category A
Awg Gauge:
AWG 14...AWG 2/0 aluminium/copper
Range:
PowerPact
Mounting Height:
38.1 mm
Device Short Name:
BD 100
Mounting Mode:
I-Line
9 Mm Pitches:
3
Net Weight:
0.6375 kg
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Ambient Air Temperature For Storage:
-50-85 °C
Width:
27 mm
Halogen Content Performance:
Halogen free product
Ik Degree Of Protection:
IK07 IEC 62262
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Quantity Per Set:
set of 1
[Ics] Rated Service Breaking Capacity:
25 kA 220...240 V AC 50/60 Hz IEC 60947-2
Breaking Capacity:
25 kA 208Y/120 V AC 50/60 Hz UL 489 || 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480Y/277 V AC 50/60 Hz UL 489 || 14 kA 125 V DC 50/60 Hz UL 489 || 10 kA 600/347 V AC 50/60 Hz UL 489
Circuit Breaker Application:
HACR rated
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Ambient Air Temperature For Operation:
-25-70 °C
Local Signalling:
presence of auxiliary contacts flag green)
Suitability For Isolation:
yes IEC 60947-2
Mechanical Durability:
20000 cycles IEC 947-1 Annex K ed 5.2
Quality Labels:
CE
  • Schneider Electric BDA161005 Molded Case Circuit Breaker 347V 100A
  • Schneider Electric BDA161005 Molded Case Circuit Breaker 347V 100A
  • Schneider Electric BDA161005 Molded Case Circuit Breaker 347V 100A
$429.00

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. I-Line circuit breakers come with a shrouded I-Line plug on jaw. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT B, 100A, 1 pole, circuit breaker has a breaking capacity of 14kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80% with a C phase connection. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose