Schneider Electric BDA161251 Molded Case Circuit Breaker 347V 100A

(No reviews yet) Write a Review
SKU:
BDA161251
UPC:
3606481151148
Condition:
New
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Ambient Air Temperature For Storage:
-50-85 °C
Device Application:
distribution
Ik Degree Of Protection:
IK07 IEC 62262
Mechanical Durability:
20000 cycles IEC 947-1 Annex K ed 5.2
Halogen Content Performance:
Halogen free product
Local Signalling:
presence of auxiliary contacts flag green)
Net Weight:
0.6375 kg
Continuous Current Rating:
0.8
Connection Pitch:
27 mm
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
Wire Stripping Length:
20 mm
Tightening Torque:
3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)
Range:
PowerPact
Quantity Per Set:
set of 1
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Eu Rohs Directive:
Compliant
Breaking Capacity Code:
D
Network Frequency:
50/60 Hz
Sustainable Offer Status:
Green Premium product
[Ics] Rated Service Breaking Capacity:
25 kA 220...240 V AC 50/60 Hz IEC 60947-2
Pollution Degree:
3 IEC 60947-1
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
9 Mm Pitches:
3
Rohs Exemption Information:
Yes
Control Type:
toggle
Quality Labels:
CE
Mercury Free:
Yes
Width:
27 mm
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Electrical Connection:
I-Line connection, line || lugs, load
Height:
137 mm
Line Rated Current:
125-125 A
Standards:
NMX J-266 || EN/IEC 60947-5-1 || GB 14048.2 || CSA C22.2 No 5 || EN/IEC 60947-2 || NEMA AB1 || UL 489
Product Or Component Type:
circuit breaker
Phase Connection:
A
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
Suitability For Isolation:
yes IEC 60947-2
Device Short Name:
BD 125
Ambient Air Temperature For Operation:
-25-70 °C
Mounting Height:
38.1 mm
Awg Gauge:
AWG 14...AWG 2/0 aluminium/copper
Ip Degree Of Protection:
front cover IP40 IEC 60529
Poles Description:
1P
Product Name:
PowerPact B
Utilisation Category:
category A
[Ue] Rated Operational Voltage:
240 V AC 50/60 Hz UL 489
Trip Unit Technology:
thermal-magnetic
Color:
Gray RAL 7016)
Pvc Free:
Yes
Breaking Capacity:
25 kA 208Y/120 V AC 50/60 Hz UL 489 || 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480Y/277 V AC 50/60 Hz UL 489 || 14 kA 125 V DC 50/60 Hz UL 489 || 10 kA 600/347 V AC 50/60 Hz UL 489
Circuit Breaker Application:
HACR rated
Environmental Disclosure:
ENVPEP1610005EN
Mounting Mode:
I-Line
Depth:
89 mm
  • Schneider Electric BDA161251 Molded Case Circuit Breaker 347V 100A
  • Schneider Electric BDA161251 Molded Case Circuit Breaker 347V 100A
  • Schneider Electric BDA161251 Molded Case Circuit Breaker 347V 100A
$966.00

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. I-Line circuit breakers come with a shrouded I-Line plug on jaw. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT B, 125A, 1 pole, circuit breaker has a breaking capacity of 14kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80% with an A phase connection. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose