- Eu Rohs Directive:
- Compliant with Exemptions
- [Ics] Rated Service Breaking Capacity:
- 25 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 14 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 18 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 18 kA 440 V AC 50/60 Hz IEC 60947-2
- Mounting Height:
- 76.2 mm
- Number Of Slots:
- 1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in)
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Connection Pitch:
- 27 mm
- Ik Degree Of Protection:
- IK07 IEC 62262
- Electrical Connection:
- I-Line connection, line || lugs, load
- Halogen Content Performance:
- Halogen free product
- Local Signalling:
- presence of auxiliary contacts flag green)
- Utilisation Category:
- category A
- Product Or Component Type:
- circuit breaker
- Standards:
- EN/IEC 60947-5-1 || EN/IEC 60947-2 || CSA C22.2 No 5 || UL 489 || GB 14048.2 || NMX J-266 || NEMA AB1
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- Width:
- 54 mm
- Suitability For Isolation:
- yes IEC 60947-2
- Mechanical Durability:
- 20000 cycles IEC 947-1 Annex K ed 5.2
- Wire Stripping Length:
- 20 mm
- Height:
- 137 mm
- Pollution Degree:
- 3 IEC 60947-1
- Breaking Capacity:
- 25 kA 208Y/120 V AC 50/60 Hz UL 489 || 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480/277 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz UL 489 || 14 kA 600Y/347 V AC 50/60 Hz UL 489 || 10 kA 250 V DC UL 489
- Ambient Air Temperature For Operation:
- -25-70 °C
- Quantity Per Set:
- set of 1
- Depth:
- 89 mm
- Circularity Profile:
- N/A
- Line Rated Current:
- 30-30 A
- Rohs Exemption Information:
- Yes
- Phase Connection:
- BC
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Device Application:
- distribution
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Quality Labels:
- CE
- [Ui] Rated Insulation Voltage:
- 800 V IEC 60947-2
- Mounting Mode:
- I-Line
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Color:
- Gray RAL 7016)
- Pvc Free:
- Yes
- Environmental Disclosure:
- ENVPEP1610005EN
- [Ue] Rated Operational Voltage:
- 525 V AC 50/60 Hz UL 489
- Awg Gauge:
- AWG 14...AWG 2/0 aluminium/copper
- Sustainable Offer Status:
- Green Premium product
- Net Weight:
- 0.952 kg
- Continuous Current Rating:
- 0.8
- Product Certifications:
- UL || IEC || CCC || EAC || CSA || NOM
- Trip Unit Technology:
- thermal-magnetic
- Circuit Breaker Application:
- HACR rated
- Electrical Durability:
- 10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
- Ambient Air Temperature For Storage:
- -50-85 °C
- Network Frequency:
- 50/60 Hz
- Device Short Name:
- BD 030
- Poles Description:
- 2P
- Product Name:
- PowerPact B
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Control Type:
- toggle
- Mercury Free:
- Yes
- 9 Mm Pitches:
- 6
- Breaking Capacity Code:
- D
- Range:
- PowerPact
- Tightening Torque:
- 3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)