- Trip Unit Technology:
- thermal-magnetic
- Pollution Degree:
- 3 IEC 60947-1
- Halogen Content Performance:
- Halogen free product
- Suitability For Isolation:
- yes IEC 60947-2
- Device Application:
- distribution
- Utilisation Category:
- category A
- Electrical Connection:
- I-Line connection, line || lugs, load
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Network Frequency:
- 50/60 Hz
- [Ui] Rated Insulation Voltage:
- 800 V IEC 60947-2
- Control Type:
- toggle
- Mounting Height:
- 114 mm
- Product Or Component Type:
- circuit breaker
- Ik Degree Of Protection:
- IK07 IEC 62262
- Depth:
- 89 mm
- Awg Gauge:
- AWG 14...AWG 2/0 aluminium/copper
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- Wire Stripping Length:
- 20 mm
- Product Name:
- PowerPact B
- Color:
- Gray RAL 7016)
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Height:
- 137 mm
- Width:
- 81 mm
- Breaking Capacity Code:
- D
- Breaking Capacity:
- 25 kA 208Y/120 V AC 50/60 Hz UL 489 || 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480/277 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz UL 489 || 14 kA 600Y/347 V AC 50/60 Hz UL 489 || 10 kA 250 V DC UL 489
- Range:
- PowerPact
- Continuous Current Rating:
- 0.8
- Circuit Breaker Application:
- HACR rated
- Ambient Air Temperature For Operation:
- -25-70 °C
- Poles Description:
- 3P
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Circularity Profile:
- N/A
- [Ics] Rated Service Breaking Capacity:
- 25 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 14 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 18 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 18 kA 440 V AC 50/60 Hz IEC 60947-2
- Product Certifications:
- UL || IEC || CCC || EAC || CSA || NOM
- Mercury Free:
- Yes
- Standards:
- NMX J-266 || EN/IEC 60947-5-1 || GB 14048.2 || UL 489 || EN/IEC 60947-2 || NEMA AB1 || CSA C22.2 No 5
- Connection Pitch:
- 27 mm
- Mounting Mode:
- I-Line
- Pvc Free:
- Yes
- Eu Rohs Directive:
- Compliant with Exemptions
- Rohs Exemption Information:
- Yes
- Tightening Torque:
- 3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)
- Mechanical Durability:
- 20000 cycles IEC 947-1 Annex K ed 5.2
- Net Weight:
- 1.315 kg
- Phase Connection:
- ABC
- Environmental Disclosure:
- ENVPEP1610005EN
- Ambient Air Temperature For Storage:
- -50-85 °C
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- [Ue] Rated Operational Voltage:
- 525 V AC 50/60 Hz UL 489
- 9 Mm Pitches:
- 9
- Sustainable Offer Status:
- Green Premium product
- Number Of Slots:
- 1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in) || 1 alarm switch SD plug-in)
- Device Short Name:
- BD 060
- Quantity Per Set:
- set of 1
- Line Rated Current:
- 60-60 A
- Electrical Durability:
- 10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
- Quality Labels:
- CE
- Local Signalling:
- presence of auxiliary contacts flag green)