- Continuous Current Rating:
- 0.8
- Suitability For Isolation:
- yes IEC 60947-2
- Breaking Capacity:
- 65 kA 208Y/120 V AC 50/60 Hz UL 489 || 65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480/277 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 18 kA 600Y/347 V AC 50/60 Hz UL 489
- [Ui] Rated Insulation Voltage:
- 800 V IEC 60947-2
- Depth:
- 89 mm
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Poles Description:
- 2P
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Halogen Content Performance:
- Halogen free product
- Breaking Capacity Code:
- G
- Mechanical Durability:
- 20000 cycles IEC 947-1 Annex K ed 5.2
- Net Weight:
- 0.952 kg
- Electrical Connection:
- I-Line connection, line || lugs, load
- Control Type:
- toggle
- Phase Connection:
- AB
- Eu Rohs Directive:
- Compliant with Exemptions
- Product Certifications:
- UL || IEC || CCC || EAC || CSA || NOM
- Line Rated Current:
- 20-20 A
- Pollution Degree:
- 3 IEC 60947-1
- Sustainable Offer Status:
- Green Premium product
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- Quality Labels:
- CE
- Width:
- 54 mm
- Awg Gauge:
- AWG 14...AWG 2/0 aluminium/copper
- Mounting Height:
- 76.2 mm
- 9 Mm Pitches:
- 6
- Circuit Breaker Application:
- HACR rated
- Rohs Exemption Information:
- Yes
- Ik Degree Of Protection:
- IK07 IEC 62262
- Mounting Mode:
- I-Line
- Device Application:
- distribution
- Local Signalling:
- presence of auxiliary contacts flag green)
- Number Of Slots:
- 1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in)
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Ambient Air Temperature For Storage:
- -50-85 °C
- Connection Pitch:
- 27 mm
- Ambient Air Temperature For Operation:
- -25-70 °C
- Standards:
- GB 14048.2 || CSA C22.2 No 5 || NMX J-266 || EN/IEC 60947-5-1 || UL 489 || EN/IEC 60947-2 || NEMA AB1
- Color:
- Gray RAL 7016)
- Device Short Name:
- BG 020
- Network Frequency:
- 50/60 Hz
- Tightening Torque:
- 3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)
- Trip Unit Technology:
- thermal-magnetic
- [Ics] Rated Service Breaking Capacity:
- 65 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 18 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 35 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 35 kA 440 V AC 50/60 Hz IEC 60947-2
- Wire Stripping Length:
- 20 mm
- Utilisation Category:
- category A
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Electrical Durability:
- 10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
- Environmental Disclosure:
- ENVPEP1610005EN
- Product Or Component Type:
- circuit breaker
- Quantity Per Set:
- set of 1
- [Ue] Rated Operational Voltage:
- 525 V AC 50/60 Hz UL 489
- Product Name:
- PowerPact B
- Circularity Profile:
- N/A
- Mercury Free:
- Yes
- Height:
- 137 mm
- Pvc Free:
- Yes
- Range:
- PowerPact