- Quantity Per Set:
- set of 1
- Ambient Air Temperature For Storage:
- -50-85 °C
- Product Certifications:
- UL || IEC || CCC || EAC || CSA || NOM
- Breaking Capacity:
- 65 kA 208Y/120 V AC 50/60 Hz UL 489 || 65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480/277 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 250 V DC UL 489 || 20 kA 600Y/347 V AC 50/60 Hz UL 489
- Wire Stripping Length:
- 20 mm
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- Mechanical Durability:
- 20000 cycles IEC 947-1 Annex K ed 5.2
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Circuit Breaker Application:
- HACR rated
- Pvc Free:
- Yes
- Mounting Height:
- 76.2 mm
- Number Of Slots:
- 1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in)
- Awg Gauge:
- AWG 14...AWG 2/0 aluminium/copper
- Product Name:
- PowerPact B
- Environmental Disclosure:
- ENVPEP1610005EN
- Rohs Exemption Information:
- Yes
- Product Or Component Type:
- circuit breaker
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Device Application:
- distribution
- Mercury Free:
- Yes
- Ik Degree Of Protection:
- IK07 IEC 62262
- Standards:
- GB 14048.2 || UL 489 || CSA C22.2 No 5 || EN/IEC 60947-2 || NMX J-266 || NEMA AB1 || EN/IEC 60947-5-1
- Device Short Name:
- BG 015
- Local Signalling:
- presence of auxiliary contacts flag green)
- Depth:
- 89 mm
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Pollution Degree:
- 3 IEC 60947-1
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Width:
- 54 mm
- Range:
- PowerPact
- Utilisation Category:
- category A
- Height:
- 137 mm
- Eu Rohs Directive:
- Compliant with Exemptions
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Control Type:
- toggle
- Poles Description:
- 2P
- Halogen Content Performance:
- Halogen free product
- Phase Connection:
- AC
- Tightening Torque:
- 3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)
- Continuous Current Rating:
- 0.8
- Connection Pitch:
- 27 mm
- [Ue] Rated Operational Voltage:
- 525 V AC 50/60 Hz UL 489
- Line Rated Current:
- 15-15 A
- Electrical Connection:
- I-Line connection, line || lugs, load
- Electrical Durability:
- 10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
- Circularity Profile:
- N/A
- 9 Mm Pitches:
- 6
- Network Frequency:
- 50/60 Hz
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Mounting Mode:
- I-Line
- [Ics] Rated Service Breaking Capacity:
- 65 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 18 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 35 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 35 kA 440 V AC 50/60 Hz IEC 60947-2
- Ambient Air Temperature For Operation:
- -25-70 °C
- Net Weight:
- 0.952 kg
- Sustainable Offer Status:
- Green Premium product
- [Ui] Rated Insulation Voltage:
- 800 V IEC 60947-2
- Trip Unit Technology:
- thermal-magnetic
- Suitability For Isolation:
- yes IEC 60947-2
- Breaking Capacity Code:
- G
- Color:
- Gray RAL 7016)
- Quality Labels:
- CE