- 9 Mm Pitches:
- 6
- Halogen Content Performance:
- Halogen free product
- Net Weight:
- 0.952 kg
- Mercury Free:
- Yes
- Local Signalling:
- presence of auxiliary contacts flag green)
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Eu Rohs Directive:
- Compliant with Exemptions
- Breaking Capacity Code:
- G
- Device Application:
- distribution
- Ik Degree Of Protection:
- IK07 IEC 62262
- Utilisation Category:
- category A
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Wire Stripping Length:
- 20 mm
- Rohs Exemption Information:
- Yes
- Connection Pitch:
- 27 mm
- Trip Unit Technology:
- thermal-magnetic
- Pvc Free:
- Yes
- Quantity Per Set:
- set of 1
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Height:
- 137 mm
- Ambient Air Temperature For Storage:
- -50-85 °C
- [Ue] Rated Operational Voltage:
- 525 V AC 50/60 Hz UL 489
- Device Short Name:
- BG 040
- Color:
- Gray RAL 7016)
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Breaking Capacity:
- 65 kA 208Y/120 V AC 50/60 Hz UL 489 || 65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480/277 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 250 V DC UL 489 || 20 kA 600Y/347 V AC 50/60 Hz UL 489
- Mounting Height:
- 76.2 mm
- Continuous Current Rating:
- 0.8
- Sustainable Offer Status:
- Green Premium product
- Ambient Air Temperature For Operation:
- -25-70 °C
- Environmental Disclosure:
- ENVPEP1610005EN
- Width:
- 54 mm
- Product Or Component Type:
- circuit breaker
- [Ui] Rated Insulation Voltage:
- 800 V IEC 60947-2
- Standards:
- UL 489 || EN/IEC 60947-2 || GB 14048.2 || CSA C22.2 No 5 || EN/IEC 60947-5-1 || NEMA AB1 || NMX J-266
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- [Ics] Rated Service Breaking Capacity:
- 65 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 18 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 35 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 35 kA 440 V AC 50/60 Hz IEC 60947-2
- Depth:
- 89 mm
- Poles Description:
- 2P
- Quality Labels:
- CE
- Circularity Profile:
- N/A
- Range:
- PowerPact
- Product Name:
- PowerPact B
- Awg Gauge:
- AWG 14...AWG 2/0 aluminium/copper
- Network Frequency:
- 50/60 Hz
- Control Type:
- toggle
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- Electrical Durability:
- 10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
- Mounting Mode:
- I-Line
- Line Rated Current:
- 40-40 A
- Phase Connection:
- BC
- Electrical Connection:
- I-Line connection, line || lugs, load
- Number Of Slots:
- 1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in)
- Suitability For Isolation:
- yes IEC 60947-2
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Pollution Degree:
- 3 IEC 60947-1
- Tightening Torque:
- 3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)
- Product Certifications:
- UL || IEC || CCC || EAC || CSA || NOM
- Circuit Breaker Application:
- HACR rated
- Mechanical Durability:
- 20000 cycles IEC 947-1 Annex K ed 5.2