- Mechanical Durability:
- 20000 cycles IEC 947-1 Annex K ed 5.2
- Product Certifications:
- UL || IEC || CCC || EAC || CSA || NOM
- Continuous Current Rating:
- 0.8
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Utilisation Category:
- category A
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Connection Pitch:
- 27 mm
- Halogen Content Performance:
- Halogen free product
- Ik Degree Of Protection:
- IK07 IEC 62262
- Mounting Height:
- 76.2 mm
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Circuit Breaker Application:
- HACR rated
- Ambient Air Temperature For Operation:
- -25-70 °C
- Width:
- 54 mm
- Breaking Capacity:
- 65 kA 208Y/120 V AC 50/60 Hz UL 489 || 65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480/277 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 250 V DC UL 489 || 20 kA 600Y/347 V AC 50/60 Hz UL 489
- Ambient Air Temperature For Storage:
- -50-85 °C
- [Ue] Rated Operational Voltage:
- 525 V AC 50/60 Hz UL 489
- Wire Stripping Length:
- 20 mm
- 9 Mm Pitches:
- 6
- Network Frequency:
- 50/60 Hz
- Rohs Exemption Information:
- Yes
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Color:
- Gray RAL 7016)
- [Ui] Rated Insulation Voltage:
- 800 V IEC 60947-2
- Local Signalling:
- presence of auxiliary contacts flag green)
- Range:
- PowerPact
- Device Short Name:
- BG 070
- Device Application:
- distribution
- Trip Unit Technology:
- thermal-magnetic
- Line Rated Current:
- 70-70 A
- Height:
- 137 mm
- Product Or Component Type:
- circuit breaker
- Awg Gauge:
- AWG 14...AWG 2/0 aluminium/copper
- Poles Description:
- 2P
- Tightening Torque:
- 3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Pvc Free:
- Yes
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Pollution Degree:
- 3 IEC 60947-1
- Quantity Per Set:
- set of 1
- Product Name:
- PowerPact B
- Electrical Durability:
- 10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
- Net Weight:
- 0.952 kg
- Breaking Capacity Code:
- G
- Number Of Slots:
- 1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in)
- Electrical Connection:
- I-Line connection, line || lugs, load
- Standards:
- NEMA AB1 || EN/IEC 60947-5-1 || NMX J-266 || GB 14048.2 || EN/IEC 60947-2 || UL 489 || CSA C22.2 No 5
- Phase Connection:
- AB
- Sustainable Offer Status:
- Green Premium product
- Mounting Mode:
- I-Line
- Circularity Profile:
- N/A
- Quality Labels:
- CE
- Depth:
- 89 mm
- Suitability For Isolation:
- yes IEC 60947-2
- [Ics] Rated Service Breaking Capacity:
- 65 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 18 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 35 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 35 kA 440 V AC 50/60 Hz IEC 60947-2
- Control Type:
- toggle
- Eu Rohs Directive:
- Compliant with Exemptions
- Environmental Disclosure:
- ENVPEP1610005EN
- Mercury Free:
- Yes