- Breaking Capacity:
- 100 kA 208Y/120 V AC 50/60 Hz UL 489 || 100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480/277 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600Y/347 V AC 50/60 Hz UL 489 || 50 kA 250 V DC UL 489
- Network Frequency:
- 50/60 Hz
- Suitability For Isolation:
- yes IEC 60947-2
- Connection Pitch:
- 27 mm
- Product Name:
- PowerPact B
- Mounting Mode:
- I-Line
- Control Type:
- toggle
- Trip Unit Technology:
- thermal-magnetic
- Poles Description:
- 3P
- Electrical Connection:
- I-Line connection, line || lugs, load
- [Ics] Rated Service Breaking Capacity:
- 100 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 25 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 10 kA 690 V AC 50/60 Hz IEC 60947-2 || 65 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 65 kA 440 V AC 50/60 Hz IEC 60947-2
- Range:
- PowerPact
- Ambient Air Temperature For Operation:
- -25-70 °C
- Depth:
- 89 mm
- Net Weight:
- 1.315 kg
- Device Short Name:
- BJ 015
- Pvc Free:
- Yes
- Rohs Exemption Information:
- Yes
- Pollution Degree:
- 3 IEC 60947-1
- Product Or Component Type:
- circuit breaker
- Mechanical Durability:
- 20000 cycles IEC 947-1 Annex K ed 5.2
- Number Of Slots:
- 1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in) || 1 alarm switch SD plug-in)
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Breaking Capacity Code:
- J
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Device Application:
- distribution
- Utilisation Category:
- category A
- Width:
- 81 mm
- Ik Degree Of Protection:
- IK07 IEC 62262
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz UL 489
- Product Certifications:
- UL || IEC || CCC || EAC || CSA || NOM
- Eu Rohs Directive:
- Compliant with Exemptions
- Quality Labels:
- CE
- Awg Gauge:
- AWG 14...AWG 2/0 aluminium/copper
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Standards:
- NMX J-266 || EN/IEC 60947-5-1 || GB 14048.2 || EN/IEC 60947-2 || UL 489 || CSA C22.2 No 5 || NEMA AB1
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- Continuous Current Rating:
- 0.8
- Tightening Torque:
- 3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)
- Phase Connection:
- ABC
- Mercury Free:
- Yes
- Halogen Content Performance:
- Halogen free product
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Line Rated Current:
- 15-15 A
- Wire Stripping Length:
- 20 mm
- Quantity Per Set:
- set of 1
- Electrical Durability:
- 10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Environmental Disclosure:
- ENVPEP1610005EN
- Ambient Air Temperature For Storage:
- -50-85 °C
- Sustainable Offer Status:
- Green Premium product
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Color:
- Gray RAL 7016)
- Mounting Height:
- 114 mm
- Height:
- 137 mm
- 9 Mm Pitches:
- 9
- Circularity Profile:
- N/A
- Circuit Breaker Application:
- HACR rated
- [Ui] Rated Insulation Voltage:
- 800 V IEC 60947-2
- Local Signalling:
- presence of auxiliary contacts flag green)