Line Rated Current:
50-50 A
Poles Description:
3P
Utilisation Category:
category A
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Range:
PowerPact
Number Of Slots:
1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in) || 1 alarm switch SD plug-in)
Rohs Exemption Information:
Yes
Eu Rohs Directive:
Compliant with Exemptions
9 Mm Pitches:
9
Circularity Profile:
N/A
Control Type:
toggle
Breaking Capacity:
100 kA 208Y/120 V AC 50/60 Hz UL 489 || 100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480/277 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600Y/347 V AC 50/60 Hz UL 489 || 50 kA 250 V DC UL 489
Device Application:
distribution
Continuous Current Rating:
0.8
Width:
81 mm
Ik Degree Of Protection:
IK07 IEC 62262
Ip Degree Of Protection:
front cover IP40 IEC 60529
Breaking Capacity Code:
J
Mercury Free:
Yes
Awg Gauge:
AWG 6...AWG 2/0 fine stranded aluminium/copper || AWG 14...AWG 3/0 rigid or stranded aluminium/copper
Mechanical Durability:
20000 cycles IEC 947-1 Annex K ed 5.2
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Depth:
80 mm
Quantity Per Set:
set of 1
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz UL 489
Electrical Connection:
Everlink lug, line || Everlink lug, load
Product Or Component Type:
circuit breaker
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Product Name:
PowerPact B
Height:
137 mm
Tightening Torque:
5-5 N.m 2.5-16 mm² (AWG 14...AWG 4) || 9-9 N.m 25-95 mm² (AWG 3...AWG 3/0)
Standards:
NEMA AB1 || GB 14048.2 || NMX J-266 || EN/IEC 60947-2 || EN/IEC 60947-5-1 || UL 489 || CSA C22.2 No 5
Device Short Name:
BJ 050
Wire Stripping Length:
20 mm
Circuit Breaker Application:
HACR rated
Quality Labels:
CE
Environmental Disclosure:
ENVPEP1610005EN
Color:
Gray RAL 7016)
[Ics] Rated Service Breaking Capacity:
100 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 25 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 10 kA 690 V AC 50/60 Hz IEC 60947-2 || 65 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 65 kA 440 V AC 50/60 Hz IEC 60947-2
Trip Unit Technology:
thermal-magnetic
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Mounting Mode:
clip-on 35 x 15 mm symmetrical DIN rail) || by screws plate)
Suitability For Isolation:
yes IEC 60947-2
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Network Frequency:
50/60 Hz
Net Weight:
1.074 kg
Connection Pitch:
27 mm
Pvc Free:
Yes
Local Signalling:
presence of auxiliary contacts flag green)
Pollution Degree:
3 IEC 60947-1
Ambient Air Temperature For Storage:
-50-85 °C
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Sustainable Offer Status:
Green Premium product
Ambient Air Temperature For Operation:
-25-70 °C
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric BJL36050 Molded Case Circuit Brkr 600Y/347V 50A
  • Schneider Electric BJL36050 Molded Case Circuit Brkr 600Y/347V 50A
  • Schneider Electric BJL36050 Molded Case Circuit Brkr 600Y/347V 50A
$1,754.00

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 25kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. This circuit breaker's unit mount construction features traditional back pan mounting with screws or integrated DIN rail mounting for installation flexibility. This unit features EverLink lugs, a patented design to reduce loosening of cables over time, on both termination ends. This PowerPacT B, 50A, 3 pole, circuit breaker has a breaking capacity of 25kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose