Schneider Electric BJL36060 Molded Case Circuit Brkr 600Y/347V 60A

(No reviews yet) Write a Review
SKU:
BJL36060
UPC:
3606481186034
Condition:
New
Pvc Free:
Yes
Local Signalling:
presence of auxiliary contacts flag green)
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Mercury Free:
Yes
Ik Degree Of Protection:
IK07 IEC 62262
Electrical Connection:
Everlink lug, line || Everlink lug, load
Range:
PowerPact
Suitability For Isolation:
yes IEC 60947-2
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz UL 489
Ambient Air Temperature For Storage:
-50-85 °C
Control Type:
toggle
Utilisation Category:
category A
Quantity Per Set:
set of 1
Mechanical Durability:
20000 cycles IEC 947-1 Annex K ed 5.2
Ip Degree Of Protection:
front cover IP40 IEC 60529
Ambient Air Temperature For Operation:
-25-70 °C
Eu Rohs Directive:
Compliant with Exemptions
Device Application:
distribution
Rohs Exemption Information:
Yes
[Ics] Rated Service Breaking Capacity:
100 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 25 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 10 kA 690 V AC 50/60 Hz IEC 60947-2 || 65 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 65 kA 440 V AC 50/60 Hz IEC 60947-2
Circularity Profile:
N/A
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Mounting Mode:
clip-on 35 x 15 mm symmetrical DIN rail) || by screws plate)
Height:
137 mm
Standards:
GB 14048.2 || EN/IEC 60947-2 || NEMA AB1 || EN/IEC 60947-5-1 || NMX J-266 || CSA C22.2 No 5 || UL 489
Breaking Capacity:
100 kA 208Y/120 V AC 50/60 Hz UL 489 || 100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480/277 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600Y/347 V AC 50/60 Hz UL 489 || 50 kA 250 V DC UL 489
Wire Stripping Length:
20 mm
Pollution Degree:
3 IEC 60947-1
Breaking Capacity Code:
J
Line Rated Current:
60-60 A
Continuous Current Rating:
0.8
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Environmental Disclosure:
ENVPEP1610005EN
Poles Description:
3P
Tightening Torque:
5-5 N.m 2.5-16 mm² (AWG 14...AWG 4) || 9-9 N.m 25-95 mm² (AWG 3...AWG 3/0)
Awg Gauge:
AWG 6...AWG 2/0 fine stranded aluminium/copper || AWG 14...AWG 3/0 rigid or stranded aluminium/copper
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
9 Mm Pitches:
9
Color:
Gray RAL 7016)
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Product Or Component Type:
circuit breaker
Product Name:
PowerPact B
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Net Weight:
1.074 kg
Device Short Name:
BJ 060
Width:
81 mm
Trip Unit Technology:
thermal-magnetic
Depth:
80 mm
Sustainable Offer Status:
Green Premium product
Halogen Content Performance:
Halogen free product
Circuit Breaker Application:
HACR rated
Network Frequency:
50/60 Hz
Number Of Slots:
1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in) || 1 alarm switch SD plug-in)
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Connection Pitch:
27 mm
Quality Labels:
CE
  • Schneider Electric BJL36060 Molded Case Circuit Brkr 600Y/347V 60A
  • Schneider Electric BJL36060 Molded Case Circuit Brkr 600Y/347V 60A
  • Schneider Electric BJL36060 Molded Case Circuit Brkr 600Y/347V 60A
$1,754.00

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 25kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. This circuit breaker's unit mount construction features traditional back pan mounting with screws or integrated DIN rail mounting for installation flexibility. This unit features EverLink lugs, a patented design to reduce loosening of cables over time, on both termination ends. This PowerPacT B, 60A, 3 pole, circuit breaker has a breaking capacity of 25kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose