Schneider Electric BJL36060LU Molded Case Circuit Brkr 600Y/347V 60A

(No reviews yet) Write a Review
SKU:
BJL36060LU
UPC:
3606481149732
Condition:
New
Operating Altitude:
6561.68 ft (2000 m) without derating || 5000 m with derating
Environmental Disclosure:
ENVPEP1610005EN
Protected Poles Description:
3t
Ambient Air Temperature For Operation:
-25-70 °C
Color:
Gray RAL 7016)
Circuit Breaker Application:
HACR rated
Ip Degree Of Protection:
front cover IP40 IEC 60529
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
Device Application:
distribution
Awg Gauge:
AWG 6...AWG 2/0 fine stranded aluminium/copper || AWG 14...AWG 3/0 rigid or stranded aluminium/copper
[Ics] Rated Service Breaking Capacity:
100 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 25 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 2.5 kA 690 V AC 50/60 Hz IEC 60947-2 || 65 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 65 kA 440 V AC 50/60 Hz IEC 60947-2
Rohs Exemption Information:
Yes
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Electrical Connection:
Everlink lug, line || Everlink lug, load
Trip Unit Technology:
thermal-magneticTM-D,
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Height:
137 mm
Breaking Capacity:
100 kA 208Y/120 V AC 50/60 Hz UL 489 || 100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480/277 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600Y/347 V AC 50/60 Hz UL 489 || 50 kA 250 V DC UL 489
Line Rated Current:
60-60 A
Pollution Degree:
3 IEC 60947-1
Trip Unit Name:
TM-D
Mechanical Durability:
15000 cycles IEC 947-1 Annex K ed 5.2
Depth:
80 mm
9 Mm Pitches:
9
Breaking Capacity Code:
J
Control Type:
toggle
Mounting Mode:
clip-on 35 mm symmetrical DIN rail) || by screws plate)
Quantity Per Set:
set of 1
Product Name:
PowerPact B
Net Weight:
1.074 kg
Ambient Air Temperature For Storage:
-50-85 °C
Eu Rohs Directive:
Compliant
Utilisation Category:
category A
Mercury Free:
Yes
Connection Pitch:
27 mm
Wire Stripping Length:
20 mm
Local Signalling:
presence of auxiliary contacts flag green)
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
Device Short Name:
BJ 060
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Pvc Free:
Yes
Halogen Content Performance:
Halogen free product
Ik Degree Of Protection:
IK07 IEC 62262
Standards:
NEMA AB1 || EN/IEC 60947-2 || UL 489 || NMX J-266 || CSA C22.2 No 5 || EN/IEC 60947-5-1 || GB 14048.2
Sustainable Offer Status:
Green Premium product
Network Frequency:
50/60 Hz
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz UL 489
Quality Labels:
CE
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Tightening Torque:
5-5 N.m 2.5-16 mm² (AWG 14...AWG 4) || 9-9 N.m 25-95 mm² (AWG 3...AWG 3/0)
Product Or Component Type:
circuit breaker
Continuous Current Rating:
0.8
Suitability For Isolation:
yes IEC 60947-2
Range:
PowerPact
Poles Description:
3P
Number Of Slots:
1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in) || 1 alarm switch SD plug-in)
Width:
81 mm
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
  • Schneider Electric BJL36060LU Molded Case Circuit Brkr 600Y/347V 60A
  • Schneider Electric BJL36060LU Molded Case Circuit Brkr 600Y/347V 60A
  • Schneider Electric BJL36060LU Molded Case Circuit Brkr 600Y/347V 60A
$2,797.50

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 25kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. This circuit breaker's unit mount construction features traditional back pan mounting with screws or integrated DIN rail mounting for installation flexibility. This unit features EverLink lugs, a patented design to reduce loosening of cables over time, on both termination ends. The EverLink lug has a control wire terminal on the line side. This PowerPacT B, 60A, 3 pole, circuit breaker has a breaking capacity of 25kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose