Schneider Electric EDB14020AABA Miniature Circuit Breaker 277V 20A

(No reviews yet) Write a Review
SKU:
EDB14020AABA
UPC:
785901159308
Condition:
New
Circuit Breaker Application:
Switching Duty rated || HID rated || HACR rated
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Breaking Capacity Code:
D
Eu Rohs Directive:
Compliant with Exemptions
Device Short Name:
EDB
Rohs Exemption Information:
Yes
Number Of Spaces Required:
2
Ambient Air Temperature For Operation:
40 °C
Module Type:
E-Frame
Trip Unit Technology:
thermal-magnetic
Product Destination:
NF panelboard
Number Of Spaces:
2
[Ue] Rated Operational Voltage:
277 V AC
Device Composition:
alarm switch || auxiliary switch
Trip Unit Rating:
875-875 A
Range Of Product:
125 A Frame EDB-EGB-EJB
Breaking Capacity:
18 kA 277 V AC || 18 kA 240 V AC || 25 kA 120 V AC || 18 kA 120/240 V AC
Mounting Mode:
bolt-on
Depth:
4.05 in
Local Signalling:
trip indicator
Electrical Connection:
lugs aluminium
Warranty:
18 months
Height:
5.66 in
Product Certifications:
cULus || IEC
Awg Gauge:
AWG 12...AWG 6 aluminium || AWG 14...AWG 6 copper
Holding Current:
270 A
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Tightening Torque:
3.4-3.4 N.m 2.5-16 mm² (AWG 14...AWG 6)
Line Rated Current:
20 A
Net Weight:
2 lb(US)
Mercury Free:
Yes
Protection Type:
overload || short-circuit
Number Of Poles:
1
Product Or Component Type:
miniature circuit-breaker
Width:
1.96 in
$462.00

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 20A, 1 pole, and has an operating voltage of 277 VAC. It also provides a 25 kA max interrupt rating at 120 VAC. This device has a hold current of 270A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 875A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This one includes an auxiliary switch and an alarm switch. This breaker was calibrated for 40 degrees C. This product is UL Listed as Switching duty and High Intensity Discharge. HACR rated.
View AllClose