Schneider Electric EDB14020EPDBA Miniature Circuit Breaker 277V 20A
Schneider Electric
$1,388.00
$1200 Minimum Order for Non-stock Items or $60 Addl Schneider Handling Fee Applies
E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 20A, 1 pole, and has an operating voltage of 277 VAC. It also provides a 25 kA max interrupt rating at 120 VAC. This device has a hold current of 270A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 875A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This one includes 30 mA ground protection and an alarm switch. This breaker was calibrated for 40 degrees C. This product is UL Listed as Switching duty and High Intensity Discharge. HACR rated.
- Local Signalling:
- trip indicator
- Breaking Capacity Code:
- D
- Device Short Name:
- EDB
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Net Weight:
- 2 lb(US)
- Product Or Component Type:
- miniature circuit-breaker
- Depth:
- 4.05 in
- Ambient Air Temperature For Operation:
- 40 °C
- Mounting Mode:
- bolt-on
- Number Of Spaces Required:
- 2
- Eu Rohs Directive:
- Compliant with Exemptions
- Module Type:
- E-Frame
- Tightening Torque:
- 3.4-3.4 N.m 2.5-16 mm² (AWG 14...AWG 6)
- Earth-Leakage Protection Class:
- class B
- [Ue] Rated Operational Voltage:
- 277 V AC
- Protection Type:
- overload || short-circuit
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Height:
- 6.64 in
- Number Of Poles:
- 1
- Awg Gauge:
- AWG 14...AWG 6 copper || AWG 12...AWG 4 aluminium
- Trip Unit Rating:
- 875-875 A
- Product Destination:
- NF panelboard
- Earth-Leakage Sensitivity:
- 30 mA
- Device Composition:
- alarm switch
- Breaking Capacity:
- 18 kA 277 V AC || 18 kA 240 V AC || 25 kA 120 V AC || 18 kA 120/240 V AC
- Line Rated Current:
- 20 A
- Electrical Connection:
- lugs aluminium
- Mercury Free:
- Yes
- Range Of Product:
- 125 A Frame EDB-EGB-EJB
- Warranty:
- 18 months
- Holding Current:
- 270 A
- Trip Unit Technology:
- thermal-magnetic
- Number Of Spaces:
- 2
- Circuit Breaker Application:
- HACR rated || HID rated || Switching Duty rated
- Product Certifications:
- IEC || cULus
- Width:
- 1.96 in
- Rohs Exemption Information:
- Yes
- Catalog:
- View
- Datasheet:
- View