Schneider Electric EDB26025 Miniature Circuit Breaker 600V 25A
Schneider Electric
$804.00
$1200 Minimum Order for Non-stock Items or $60 Addl Schneider Handling Fee Applies
E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 25A, 2 pole, and has an operating voltage of 600Y/347 VAC. It also provides a 25 kA max interrupt rating at 120 VAC. This device has a hold current of 270A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 875A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This breaker was calibrated for 40 degrees C. This product is UL Listed as High Intensity Discharge. HACR rated.
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Number Of Spaces:
- 2
- Depth:
- 4.05 in
- Awg Gauge:
- AWG 12...AWG 6 aluminium || AWG 14...AWG 6 copper
- Line Rated Current:
- 25 A
- Tightening Torque:
- 3.4-3.4 N.m 2.5-16 mm² (AWG 14...AWG 6)
- Product Destination:
- NF panelboard
- Number Of Poles:
- 2
- Warranty:
- 18 months
- Ambient Air Temperature For Operation:
- 40 °C
- Height:
- 5.66 in
- Device Short Name:
- EDB
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Circuit Breaker Application:
- HACR rated
- Width:
- 1.96 in
- Range Of Product:
- 125 A Frame EDB-EGB-EJB
- [Ue] Rated Operational Voltage:
- 600Y/347 V AC
- Mounting Mode:
- bolt-on
- Trip Unit Rating:
- 875-875 A
- Breaking Capacity Code:
- D
- Electrical Connection:
- lugs aluminium
- Local Signalling:
- trip indicator
- Protection Type:
- overload || short-circuit
- Product Certifications:
- cULus
- Holding Current:
- 270 A
- Number Of Spaces Required:
- 2
- Mercury Free:
- Yes
- Rohs Exemption Information:
- Yes
- Product Or Component Type:
- miniature circuit-breaker
- Trip Unit Technology:
- thermal-magnetic
- Net Weight:
- 3 lb(US)
- Breaking Capacity:
- 14 kA 600Y/347 V AC
- Module Type:
- E-Frame
- Brochure:
- View
- Datasheet:
- View