Schneider Electric EDB26050 Miniature Circuit Breaker 600V 50A
Schneider Electric
$536.00
$1200 Minimum Order for Non-stock Items or $60 Addl Schneider Handling Fee Applies
E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 50A, 2 pole, and has an operating voltage of 600Y/347 VAC. It also provides a 25 kA max interrupt rating at 120 VAC. This device has a hold current of 630A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 1800A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This breaker was calibrated for 40 degrees C. This product is UL Listed as High Intensity Discharge. HACR rated.
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Range Of Product:
- 125 A Frame EDB-EGB-EJB
- Product Or Component Type:
- miniature circuit-breaker
- Number Of Poles:
- 2
- Height:
- 5.66 in
- Depth:
- 4.05 in
- Width:
- 1.96 in
- Mounting Mode:
- bolt-on
- Number Of Spaces Required:
- 2
- Electrical Connection:
- lugs aluminium
- Trip Unit Rating:
- 1800-1800 A
- Product Destination:
- NF panelboard
- Device Short Name:
- EDB
- [Ue] Rated Operational Voltage:
- 600Y/347 V AC
- Product Certifications:
- cULus
- Module Type:
- E-Frame
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Holding Current:
- 630 A
- Number Of Spaces:
- 2
- Ambient Air Temperature For Operation:
- 40 °C
- Mercury Free:
- Yes
- Local Signalling:
- trip indicator
- Circuit Breaker Application:
- HACR rated
- Warranty:
- 18 months
- Line Rated Current:
- 50 A
- Net Weight:
- 3 lb(US)
- Rohs Exemption Information:
- Yes
- Awg Gauge:
- AWG 12...AWG 2/0 aluminium || AWG 14...AWG 2/0 copper
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Trip Unit Technology:
- thermal-magnetic
- Protection Type:
- overload || short-circuit
- Breaking Capacity:
- 14 kA 600Y/347 V AC
- Breaking Capacity Code:
- D
- Tightening Torque:
- 3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0)
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View