Schneider Electric EDB34015 Miniature Circuit Breaker 480Y/277V 15A

(No reviews yet) Write a Review
SKU:
EDB34015
UPC:
785901875239
Condition:
New
Product Or Component Type:
miniature circuit-breaker
Mounting Mode:
bolt-on
Number Of Spaces Required:
3
Awg Gauge:
AWG 12...AWG 6 aluminium || AWG 14...AWG 6 copper
Trip Unit Technology:
thermal-magnetic
Number Of Poles:
3
Electrical Connection:
lugs aluminium
Mercury Free:
Yes
Number Of Spaces:
3
Depth:
4.05 in
Warranty:
18 months
Width:
2.94 in
Ambient Air Temperature For Operation:
40 °C
Holding Current:
270 A
Product Certifications:
cULus
Breaking Capacity:
18 kA 277 V AC || 25 kA 240 V AC || 18 kA 480Y/277 V AC || 25 kA 120 V AC || 25 kA 120/240 V AC
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Net Weight:
4 lb(US)
Line Rated Current:
15 A
Module Type:
E-Frame
Height:
5.66 in
Rohs Exemption Information:
Yes
Circuit Breaker Application:
HACR rated || HID rated
[Ue] Rated Operational Voltage:
480Y/277 V AC
Range Of Product:
125 A Frame EDB-EGB-EJB
Device Short Name:
EDB
Breaking Capacity Code:
D
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Tightening Torque:
3.4-3.4 N.m 2.5-16 mm² (AWG 14...AWG 6)
Trip Unit Rating:
875-875 A
Local Signalling:
trip indicator
Protection Type:
short-circuit || overload
Product Destination:
NF panelboard
$669.00

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This device is a 3 pole bolt-on breaker that is rated at 15 A at a system voltage of 480Y/277 VAC and the breaker is UL Listed as well as CSA rated. This E-Frame breaker has thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. This specific breaker is HACR rated and HID rated. The breaker has aluminium lugs which have a terminal lug rating of AWG 12...AWG 6 (aluminium) and AWG 14...AWG 6 (copper). This E-frame breaker breaking capacity has been tested a numerous voltages but at two voltages the capacity is 18 kA at 480Y/277 VAC and 25 kA at 120/240 VAC. This device has a hold current of 270 A which is the maxiumum current the breaker can be held to ensure it will trip and a trip current of 875A which is the current value when the breaker is guaranteed to trip. The circuit breaker has a height of 5.66 in, width of 2.94 in and a depth of 4.05 in. This breaker was calibrated for 40 degrees C. This product is UL Listed as High Intensity Discharge. HACR rated.
View AllClose