New
Trip Unit Technology:
thermal-magnetic
Rohs Exemption Information:
Yes
Device Composition:
alarm switch || auxiliary switch
Module Type:
E-Frame
Tightening Torque:
3.4-3.4 N.m 2.5-16 mm² (AWG 14...AWG 6)
Electrical Connection:
lugs aluminium
Mounting Mode:
bolt-on
Number Of Spaces:
4
Mercury Free:
Yes
Width:
3.92 in
Breaking Capacity Code:
D
Line Rated Current:
15 A
Product Or Component Type:
miniature circuit-breaker
Circuit Breaker Application:
HID rated || HACR rated
Height:
5.66 in
Local Signalling:
trip indicator
Breaking Capacity:
18 kA 277 V AC || 25 kA 240 V AC || 18 kA 480Y/277 V AC || 25 kA 120 V AC || 25 kA 120/240 V AC
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Protection Type:
overload || short-circuit
[Ue] Rated Operational Voltage:
480Y/277 V AC
Ambient Air Temperature For Operation:
40 °C
Product Destination:
NF panelboard
Awg Gauge:
AWG 12...AWG 6 aluminium || AWG 14...AWG 6 copper
Holding Current:
270 A
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Number Of Spaces Required:
4
Device Short Name:
EDB
Warranty:
18 months
Range Of Product:
125 A Frame EDB-EGB-EJB
Net Weight:
4 lb(US)
Number Of Poles:
3
Product Certifications:
cULus
Depth:
4.05 in
Trip Unit Rating:
875-875 A
Eu Rohs Directive:
Compliant with Exemptions
$981.00

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 15A, 3 pole, and has an operating voltage of 480Y/277 VAC. It also provides a 25 kA max interrupt rating at 120 VAC. This device has a hold current of 270A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 875A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This one includes an auxiliary switch and an alarm switch. This breaker was calibrated for 40 degrees C. This product is UL Listed as High Intensity Discharge. HACR rated.