Height:
5.66 in
Line Rated Current:
20 A
Net Weight:
4 lb(US)
Warranty:
18 months
Mercury Free:
Yes
Awg Gauge:
AWG 12...AWG 6 aluminium || AWG 14...AWG 6 copper
Breaking Capacity Code:
D
Number Of Spaces Required:
3
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Rohs Exemption Information:
Yes
Trip Unit Technology:
thermal-magnetic
Width:
2.94 in
[Ue] Rated Operational Voltage:
480Y/277 V AC
Device Short Name:
EDB
Breaking Capacity:
18 kA 277 V AC || 25 kA 240 V AC || 18 kA 480Y/277 V AC || 25 kA 120 V AC || 25 kA 120/240 V AC
Product Or Component Type:
miniature circuit-breaker
Product Destination:
NF panelboard
Module Type:
E-Frame
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Tightening Torque:
3.4-3.4 N.m 2.5-16 mm² (AWG 14...AWG 6)
Mounting Mode:
bolt-on
Product Certifications:
cULus
Range Of Product:
125 A Frame EDB-EGB-EJB
Local Signalling:
trip indicator
Circuit Breaker Application:
HID rated || HACR rated
Depth:
4.05 in
Holding Current:
270 A
Protection Type:
overload || short-circuit
Ambient Air Temperature For Operation:
50 °C
Number Of Poles:
3
Number Of Spaces:
3
Electrical Connection:
lugs aluminium
Trip Unit Rating:
875-875 A
Catalog:
View
Datasheet:
View
$1,204.50

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 20A, 3 pole, and has an operating voltage of 480Y/277 VAC. It also provides a 25 kA max interrupt rating at 120 VAC. This device has a hold current of 270A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 875A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This breaker was calibrated for 50 degrees C. This product is UL Listed as High Intensity Discharge. HACR rated.