Schneider Electric EDB34090CA Miniature Circuit Breaker 480Y/277V 90A

(No reviews yet) Write a Review
SKU:
EDB34090CA
UPC:
7.85902E+11
Condition:
New
Breaking Capacity:
18 kA 277 V AC || 25 kA 240 V AC || 18 kA 480Y/277 V AC || 25 kA 120 V AC || 25 kA 120/240 V AC
Ambient Air Temperature For Operation:
50 °C
Holding Current:
1000 A
Mounting Mode:
bolt-on
Product Or Component Type:
miniature circuit-breaker
Electrical Connection:
lugs aluminium
Range Of Product:
125 A Frame EDB-EGB-EJB
Net Weight:
4 lb(US)
Number Of Poles:
3
Circuit Breaker Application:
HACR rated
Depth:
4.05 in
Trip Unit Rating:
2300-2300 A
Breaking Capacity Code:
D
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Number Of Spaces Required:
3
Rohs Exemption Information:
Yes
Product Destination:
NF panelboard
Device Short Name:
EDB
Trip Unit Technology:
thermal-magnetic
Mercury Free:
Yes
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Protection Type:
overload || short-circuit
Tightening Torque:
3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Width:
2.94 in
Module Type:
E-Frame
[Ue] Rated Operational Voltage:
480Y/277 V AC
Local Signalling:
trip indicator
Line Rated Current:
90 A
Awg Gauge:
AWG 12...AWG 2/0 aluminium || AWG 14...AWG 2/0 copper
Height:
5.66 in
Number Of Spaces:
3
Product Certifications:
cULus
Warranty:
18 months
Datasheet:
View
  • Schneider Electric EDB34090CA Miniature Circuit Breaker 480Y/277V 90A
  • Schneider Electric EDB34090CA Miniature Circuit Breaker 480Y/277V 90A
$1,639.50

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 90A, 3 pole, and has an operating voltage of 480Y/277 VAC. It also provides a 25 kA max interrupt rating at 120 VAC. This device has a hold current of 1000A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 2300A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This breaker was calibrated for 50 degrees C. HACR rated.
View AllClose