Schneider Electric EDB36020 Miniature Circuit Breaker 600V 20A

(No reviews yet) Write a Review
SKU:
EDB36020
UPC:
7.85901E+11
Condition:
New
Depth:
4.05 in
Net Weight:
4 lb(US)
Electrical Connection:
lugs aluminium
Height:
5.66 in
Local Signalling:
trip indicator
Range Of Product:
125 A Frame EDB-EGB-EJB
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Tightening Torque:
3.4-3.4 N.m 2.5-16 mm² (AWG 14...AWG 6)
[Ue] Rated Operational Voltage:
600Y/347 V AC
Breaking Capacity:
14 kA 600Y/347 V AC
Awg Gauge:
AWG 12...AWG 6 aluminium || AWG 14...AWG 6 copper
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Mounting Mode:
bolt-on
Protection Type:
overload || short-circuit
Trip Unit Technology:
thermal-magnetic
Module Type:
E-Frame
Product Destination:
NF panelboard
Rohs Exemption Information:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Number Of Poles:
3
Ambient Air Temperature For Operation:
40 °C
Holding Current:
270 A
Product Or Component Type:
circuit-breaker
Number Of Spaces Required:
3
Number Of Spaces:
3
Circuit Breaker Application:
HACR rated
Device Short Name:
EDB
Trip Unit Rating:
875-875 A
Width:
2.94 in
Line Rated Current:
20 A
Breaking Capacity Code:
D
Product Certifications:
cULus
Warranty:
18 months
Mercury Free:
Yes
  • Schneider Electric EDB36020 Miniature Circuit Breaker 600V 20A
  • Schneider Electric EDB36020 Miniature Circuit Breaker 600V 20A
$669.00

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 20A, 3 pole, and has an operating voltage of 600Y/347 VAC. It also provides a 25 kA max interrupt rating at 120 VAC. This device has a hold current of 270A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 875A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This breaker was calibrated for 40 degrees C. This product is UL Listed as High Intensity Discharge. HACR rated.
View AllClose