Schneider Electric EGB24035 Miniature Circuit Breaker 480Y/277V 35A

(No reviews yet) Write a Review
SKU:
EGB24035
UPC:
785901335207
Condition:
New
Module Type:
E-Frame
Number Of Poles:
2
Holding Current:
630 A
Local Signalling:
trip indicator
Net Weight:
3 lb(US)
Breaking Capacity:
35 kA 277 V AC || 65 kA 240 V AC || 35 kA 480Y/277 V AC || 65 kA 120 V AC || 65 kA 120/240 V AC
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Product Destination:
NF panelboard
Mercury Free:
Yes
Trip Unit Technology:
thermal-magnetic
Width:
1.96 in
Ambient Air Temperature For Operation:
40 °C
Protection Type:
short-circuit || overload
Depth:
4.05 in
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
[Ue] Rated Operational Voltage:
480Y/277 V AC
Tightening Torque:
3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0)
Range Of Product:
125 A Frame EDB-EGB-EJB
Breaking Capacity Code:
G
Product Or Component Type:
miniature circuit-breaker
Mounting Mode:
bolt-on
Number Of Spaces Required:
2
Electrical Connection:
lugs aluminium
Device Short Name:
EGB
Awg Gauge:
AWG 12...AWG 2/0 aluminium || AWG 14...AWG 2/0 copper
Trip Unit Rating:
1800-1800 A
Circuit Breaker Application:
HACR rated || HID rated
Rohs Exemption Information:
Yes
Height:
5.66 in
Line Rated Current:
35 A
Number Of Spaces:
2
Product Certifications:
cULus
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Warranty:
18 months
$776.00

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 35A, 2 pole, and has an operating voltage of 480Y/277 VAC. It also provides a 65 kA max interrupt rating at 120 VAC. This device has a hold current of 630A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 1800A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This breaker was calibrated for 40 degrees C. This product is UL Listed as High Intensity Discharge. HACR rated.
View AllClose